72.2 | 6 | = 1. WSS-09 ~-~- 9 in 1 Weather Station Sensor = |
![]() |
2.1 | 7 | |
8 | == 1.1 Overview and Spec == | ||
9 | |||
10 | |||
![]() |
68.2 | 11 | **Older versions of interfaces New version of the interface** |
![]() |
52.1 | 12 | |
![]() |
71.3 | 13 | [[image:image-20250507141942-2.jpeg]] [[image:image-20250507141229-1.png||height="265" width="205"]] |
![]() |
68.2 | 14 | |
![]() |
8.1 | 15 | **Power Input**: 10 ~~ 30VDC |
16 | |||
17 | **Max Power Consumption**: 1.2W | ||
18 | |||
![]() |
2.1 | 19 | **Wind Speed:** |
20 | |||
21 | * Range: 0~~60m/s | ||
22 | * Accuracy: ±(0.2m/s±0.02*v)(v : the wind speed) | ||
23 | * Ultrasonic measurement,no start wind strength needed | ||
24 | |||
25 | **Wind Direction:** | ||
26 | |||
27 | * Range: 0~~3599 | ||
![]() |
63.2 | 28 | * Accuracy: ±3° |
![]() |
68.2 | 29 | * Ultrasonic measurement, no start wind strength needed |
![]() |
2.1 | 30 | * Built-in electronic compass. No need to consider installation direction |
31 | |||
32 | **Temperature:** | ||
33 | |||
34 | * Range: -40°C ~~ +80°C | ||
![]() |
63.2 | 35 | * Accuracy: ±0.5°C |
![]() |
2.1 | 36 | |
37 | **Humidity:** | ||
38 | |||
39 | * Range: 0 ~~ 99% RH | ||
![]() |
63.2 | 40 | * Accuracy Tolerance : Typ ±3% RH |
![]() |
2.1 | 41 | |
42 | **Air Pressure:** | ||
43 | |||
44 | * Accuracy: ±0.15kPa@25°C 101kPa | ||
45 | * Range: 0~~120kPa | ||
46 | |||
47 | **Noise:** | ||
48 | |||
49 | * Range: 30dB~~120dB | ||
![]() |
63.2 | 50 | * Accuracy: ±0.5dB |
![]() |
2.1 | 51 | |
52 | **PM2.5:** | ||
53 | |||
54 | * Range: 0~~1000ug/m3 | ||
55 | * Accuracy: ±3%FS | ||
56 | * Resolution: 1ug/m3 | ||
57 | |||
58 | **PM10:** | ||
59 | |||
60 | * Range: 0~~1000ug/m3 | ||
![]() |
63.2 | 61 | * Accuracy: ±3%FS |
![]() |
2.1 | 62 | * Resolution: 1ug/m3 |
63 | |||
64 | **llumination:** | ||
65 | |||
66 | * Range: 0~~200k Lux | ||
![]() |
63.2 | 67 | * Accuracy: ±7%(25 °C) |
![]() |
2.1 | 68 | |
69 | == 1.2 Wiring == | ||
70 | |||
![]() |
12.2 | 71 | === 1.2.1 Older version wiring === |
72 | |||
![]() |
2.1 | 73 | [[image:image-20240714104450-1.png||height="239" width="445"]] |
74 | |||
75 | |||
![]() |
12.2 | 76 | === 1.2.2 New version wiring === |
77 | |||
![]() |
75.1 | 78 | [[image:image-20250507161616-1.png||height="363" width="682"]] |
![]() |
12.2 | 79 | |
80 | |||
![]() |
8.1 | 81 | == 1.3 Mechinical Drawing == |
82 | |||
![]() |
63.2 | 83 | |
![]() |
8.1 | 84 | (% class="lead" %) |
85 | **Device Dimension** | ||
86 | |||
87 | [[image:image-20240714165651-5.png||height="308" width="245"]] | ||
88 | |||
89 | |||
90 | (% class="lead" %) | ||
91 | **Installation** | ||
92 | |||
93 | * Make sure the device is horizontal installed | ||
94 | * Device include electronic compass. No need to consider installation direction to get correct wind direction. | ||
95 | |||
![]() |
72.2 | 96 | = 2. WSS-08 ~-~- Optical Range Guage = |
![]() |
2.1 | 97 | |
98 | == 2.1 Overview and Spec == | ||
99 | |||
![]() |
63.2 | 100 | |
![]() |
71.2 | 101 | **Older versions of interfaces New version of the interface** |
![]() |
2.1 | 102 | |
![]() |
71.2 | 103 | [[image:image-20250507142027-3.jpeg]] [[image:image-20250505190822-2.png||height="155" width="197"]] |
![]() |
52.1 | 104 | |
![]() |
2.1 | 105 | * Input Power: 9~~30 VDC |
106 | * Sense diameter: 6cm | ||
![]() |
6.2 | 107 | * Pulse Output, each pulse , 0.1mm |
108 | * Max rain: 24mm/min | ||
109 | * Operation Temperature: -40 ~~ 60 °C | ||
110 | * Operation Humidify: 0~~99%RH(no dew) | ||
![]() |
2.1 | 111 | |
112 | == 2.2 Wiring == | ||
113 | |||
![]() |
21.2 | 114 | === 2.2.1 Older version wiring === |
115 | |||
![]() |
10.1 | 116 | [[image:image-20241127091433-1.jpeg||height="361" width="517"]] |
![]() |
6.2 | 117 | |
![]() |
63.2 | 118 | |
![]() |
21.2 | 119 | === 2.2.2 New version wiring === |
120 | |||
![]() |
63.2 | 121 | |
![]() |
63.1 | 122 | [[image:image-20250505193511-9.png||height="392" width="708"]] |
![]() |
21.2 | 123 | |
![]() |
6.2 | 124 | == 2.3 Mechinical Drawing == |
125 | |||
![]() |
63.2 | 126 | |
![]() |
6.2 | 127 | (% class="lead" %) |
128 | **Device Dimension** | ||
129 | |||
130 | [[image:image-20240714164433-1.png||height="211" width="548"]] | ||
131 | |||
132 | |||
133 | (% class="lead" %) | ||
134 | **Bracket Dimension** | ||
135 | |||
136 | [[image:image-20240714164803-3.png||height="306" width="836"]] | ||
137 | |||
138 | |||
139 | (% class="lead" %) | ||
![]() |
8.1 | 140 | **Install without Bracket** |
![]() |
6.2 | 141 | |
142 | [[image:image-20240714164856-4.png||height="250" width="433"]] | ||
![]() |
21.2 | 143 | |
144 | |||
![]() |
72.2 | 145 | = 3. WSS-27 ~-~- PAR (Photosynthetically Available Radiation) = |
![]() |
21.2 | 146 | |
147 | |||
![]() |
65.2 | 148 | WSS-27 photosynthetically active radiation sensor is mainly used to measure the photosynthetically active radiation of natural light in the wavelength range of 400-700nm. |
149 | |||
150 | WSS-27 use precision optical detectors and has an optical filter of 400-700nm, when natural light is irradiated, a voltage signal proportional to the intensity of the incident radiation is generated, and its luminous flux density is proportional to the cosine of the direct angle of the incident light. | ||
151 | |||
![]() |
67.2 | 152 | |
![]() |
65.2 | 153 | == 3.1 Specification == |
154 | |||
![]() |
21.2 | 155 | [[image:1746411474621-748.png||height="175" width="224"]] |
156 | |||
![]() |
65.2 | 157 | * Input Power: DC 5 ~~ 24v |
158 | * Interface: RS485 | ||
159 | * Response Spectrum: 400~~700nm | ||
160 | * Measure range: 0 ~~ 2500μmol/m2•s | ||
161 | * Resolution: 1μmol/m2•s | ||
![]() |
21.2 | 162 | * Accuracy: ±2% |
![]() |
65.2 | 163 | * Yearly Stability: ≤ ±2% |
164 | * Working Temperature: -30℃ ~~ 75℃ | ||
165 | * Working Humidity: 10 ~~ 90%RH | ||
![]() |
78.3 | 166 | * Power Consumption: 5mA @ 12v & 6mA @ 5v |
167 | * Stable Time: 5s | ||
![]() |
21.2 | 168 | |
169 | == 3.2 Wiring == | ||
170 | |||
![]() |
63.1 | 171 | [[image:image-20250505193330-8.png||height="393" width="744"]] |
![]() |
24.2 | 172 | |
![]() |
65.2 | 173 | == 3.3 Dimension == |
![]() |
21.2 | 174 | |
![]() |
65.2 | 175 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057538793-888.png?rev=1.1||alt="1656057538793-888.png"]] |
![]() |
21.2 | 176 | |
![]() |
66.3 | 177 | == 3.4 Installation Notice == |
![]() |
21.2 | 178 | |
![]() |
67.2 | 179 | |
![]() |
66.3 | 180 | Do not power on while connect the cables. Double check the wiring before power on. |
181 | |||
182 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057557191-895.png?rev=1.1||alt="1656057557191-895.png"]] | ||
183 | |||
184 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057565783-251.png?rev=1.1||alt="1656057565783-251.png"]] | ||
185 | |||
186 | |||
![]() |
72.2 | 187 | = 4. WSS-26 ~-~- Total Solar Radiation sensor = |
![]() |
21.2 | 188 | |
![]() |
67.2 | 189 | |
![]() |
65.2 | 190 | WSS-26 is Total Radiation Sensor can be used to measure the total solar radiation in the spectral range of 0.3 to 3 μm (300 to 3000 nm). If the sensor face is down, the reflected radiation can be measured, and the shading ring can also be used to measure the scattered radiation. |
![]() |
21.2 | 191 | |
![]() |
67.2 | 192 | The core device of the radiation sensor is a high-precision photosensitive element, which has good stability and high precision; at the same time, a precision-machined PTTE radiation cover is installed outside the sensing element, which effectively prevents environmental factors from affecting its performance. |
![]() |
21.2 | 193 | |
![]() |
67.2 | 194 | |
![]() |
65.2 | 195 | == 4.1 Feature == |
![]() |
21.2 | 196 | |
![]() |
67.2 | 197 | |
![]() |
65.2 | 198 | * RS485 Total Solar Radiation sensor |
199 | * Measure Total Radiation between 0.3 ~~ 3μm(300 ~~ 3000nm) | ||
200 | * Measure Reflected Radiation if sense area towards ground. | ||
201 | |||
202 | == 4.2 Specification == | ||
203 | |||
![]() |
67.2 | 204 | |
205 | (% id="cke_bm_101984S" style="display:none" %) | ||
206 | |||
![]() |
65.2 | 207 | * Input Power: DC 5 ~~ 24v |
208 | * Interface: RS485 | ||
209 | * Detect spectrum: 0.3 ~~ 3μm(300~3000nm) | ||
210 | * Measure strength range: 0 ~~ 2000W/m2 | ||
211 | * Resolution: 0.1W/m2 | ||
212 | * Accuracy: ±3% | ||
213 | * Yearly Stability: ≤±2% | ||
214 | * Cosine response: ≤7% (@ Sun angle 10°) | ||
215 | * Temperature Effect: ±2% (-10℃ ~~ 40℃) | ||
216 | * Working Temperature: -40℃ ~~ 70℃ | ||
217 | * Working Humidity: 10 ~~ 90%RH | ||
218 | * Power Consumption: 4mA @ 12v | ||
219 | |||
![]() |
68.3 | 220 | == 4.3 Wiring == |
![]() |
24.2 | 221 | |
222 | |||
![]() |
63.1 | 223 | [[image:image-20250505193313-7.png||height="391" width="722"]] |
![]() |
24.2 | 224 | |
![]() |
68.3 | 225 | == 4.4 Device Dimension == |
![]() |
24.2 | 226 | |
![]() |
65.2 | 227 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057348695-898.png?rev=1.1||alt="1656057348695-898.png"]] |
![]() |
24.2 | 228 | |
229 | |||
![]() |
68.3 | 230 | == 4.5 Installation Notice == |
![]() |
24.2 | 231 | |
![]() |
67.2 | 232 | |
![]() |
65.2 | 233 | Do not power on while connect the cables. Double check the wiring before power on. |
![]() |
24.2 | 234 | |
![]() |
65.2 | 235 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057369259-804.png?rev=1.1||alt="1656057369259-804.png"]] |
![]() |
24.2 | 236 | |
![]() |
65.2 | 237 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057377943-564.png?rev=1.1||alt="1656057377943-564.png"]] |
![]() |
24.2 | 238 | |
239 | |||
![]() |
81.2 | 240 | == 4.6 Calibration Values (K-value Adjustment) == |
![]() |
80.1 | 241 | |
![]() |
81.4 | 242 | In the event of deviations in the sensor values, calibration can be carried out by modifying the sensor's internal parameter: K-value parameter(**Default: 03E8(H)=1000(D)**). |
![]() |
80.1 | 243 | |
![]() |
81.6 | 244 | (% style="color:#037691" %)**Calibration Principle** |
![]() |
80.1 | 245 | |
![]() |
81.4 | 246 | The K-value scales the sensor's output. If multiple sensors measure the same parameter but show different values, adjust the K-value of the secondary sensor(s) to match the primary sensor's reading. |
247 | |||
![]() |
81.6 | 248 | (% style="color:#037691" %)**Step-by-Step Example:** |
![]() |
81.4 | 249 | |
![]() |
81.6 | 250 | **Scenario:** |
![]() |
81.5 | 251 | |
252 | * Sensor 1 (reference) reads 1500. | ||
253 | * Sensor 2 reads 2000, but should match Sensor 1's value (~~1500). | ||
254 | |||
![]() |
81.6 | 255 | **Steps:** |
256 | |||
![]() |
81.10 | 257 | **~1. Calculate the K-value ratio**: |
![]() |
81.7 | 258 | |
![]() |
81.9 | 259 | Ratio=Desired Value/Current Value=1500/2000=0.75 |
![]() |
81.7 | 260 | |
![]() |
81.10 | 261 | Multiply by the default K-value (1000) to get the new K-value: 0.75×1000=750(Decimal) |
![]() |
81.7 | 262 | |
![]() |
81.17 | 263 | **2. Convert the (% style="color:#037691" %)new K-value(%%) to hexadecimal**: |
![]() |
81.7 | 264 | |
![]() |
81.14 | 265 | * 750(D) = 0x02EE(H) |
![]() |
81.9 | 266 | |
![]() |
81.15 | 267 | **3. Send the calibration command to Sensor 2**: |
![]() |
81.9 | 268 | |
![]() |
81.17 | 269 | * Command Format: **0B 06 00 53 [(% style="color:#037691" %)K-value(%%) (2 bytes)] [CRC]** |
![]() |
82.1 | 270 | * Example for K-value 0x02EE: 0B 06 00 53 02 EE F8 5D |
![]() |
81.9 | 271 | |
![]() |
82.1 | 272 | (% style="color:red" %)**Notes:** |
![]() |
81.10 | 273 | |
![]() |
82.1 | 274 | ~1. Always use the sensor with the most trusted reading as the reference (do not modify its K-value). |
![]() |
81.16 | 275 | |
![]() |
82.1 | 276 | 2. The default K-value 03E8 (1000) implies no scaling. Values below 03E8 reduce the output; values above increase it. |
![]() |
80.1 | 277 | |
![]() |
82.1 | 278 | 3. CRC is auto-generated by the tool (no manual calculation needed). |
![]() |
80.1 | 279 | |
![]() |
82.1 | 280 | |
![]() |
72.2 | 281 | = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure = |
![]() |
65.2 | 282 | |
![]() |
67.2 | 283 | |
![]() |
65.2 | 284 | WSS-25 is a 4 in 1 RS485 sensor which can monitor Temperature, Humidity, Illuminance and Pressure at the same time. |
285 | |||
![]() |
67.2 | 286 | |
![]() |
65.2 | 287 | == 5.1 Feature == |
288 | |||
![]() |
67.2 | 289 | |
![]() |
65.2 | 290 | * RS485 Temperature, Humidity, Illuminance, Pressure sensor |
291 | |||
292 | == 5.2 Specification == | ||
293 | |||
294 | |||
295 | * Input Power: DC 12 ~~ 24v | ||
296 | * Interface: RS485 | ||
297 | * Temperature Sensor Spec: | ||
298 | ** Range: -30 ~~ 70℃ | ||
299 | ** resolution 0.1℃ | ||
300 | ** Accuracy: ±0.5℃ | ||
301 | * Humidity Sensor Spec: | ||
302 | ** Range: 0 ~~ 100% RH | ||
303 | ** resolution 0.1 %RH | ||
![]() |
67.2 | 304 | ** Accuracy: ±3% RH |
![]() |
65.2 | 305 | * Pressure Sensor Spec: |
306 | ** Range: 10 ~~ 1100hPa | ||
307 | ** Resolution: 0.1hPa | ||
308 | ** Accuracy: ±0.1hPa | ||
309 | * Illuminate sensor: | ||
310 | ** Range: 0~~2/20/200kLux | ||
311 | ** Resolution: 10 Lux | ||
312 | ** Accuracy: ±3%FS | ||
313 | * Working Temperature: -30℃ ~~ 70℃ | ||
314 | * Working Humidity: 10 ~~ 90%RH | ||
315 | * Power Consumption: 4mA @ 12v | ||
316 | |||
![]() |
68.3 | 317 | == 5.3 Wiring == |
![]() |
25.2 | 318 | |
![]() |
29.2 | 319 | |
![]() |
63.1 | 320 | [[image:image-20250505193252-6.png||height="409" width="765"]] |
![]() |
29.2 | 321 | |
![]() |
68.3 | 322 | == 5.4 Dimension == |
![]() |
29.2 | 323 | |
324 | |||
![]() |
65.2 | 325 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057170639-522.png?rev=1.1||alt="1656057170639-522.png"]] |
![]() |
29.2 | 326 | |
327 | |||
![]() |
68.3 | 328 | == 5.5 Installation Notice == |
![]() |
66.2 | 329 | |
![]() |
67.2 | 330 | |
![]() |
66.2 | 331 | Do not power on while connect the cables. Double check the wiring before power on. |
332 | |||
333 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057199955-514.png?rev=1.1||alt="1656057199955-514.png"]] | ||
334 | |||
335 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057212438-475.png?rev=1.1||alt="1656057212438-475.png"]] | ||
336 | |||
337 | |||
![]() |
72.2 | 338 | = 6. WSS-24 ~-~- Rain/Snow Detect = |
![]() |
29.2 | 339 | |
![]() |
67.2 | 340 | |
![]() |
65.2 | 341 | WSS-24 is a RS485 rain / snow detect sensor. It can monitor Rain or Snow event. |
![]() |
29.2 | 342 | |
![]() |
65.2 | 343 | WSS-24 has auto heating feature, this ensures measurement more reliable. |
![]() |
29.2 | 344 | |
![]() |
67.2 | 345 | == 6.1 Feature == |
![]() |
29.2 | 346 | |
![]() |
67.2 | 347 | |
![]() |
65.2 | 348 | * RS485 Rain/Snow detect sensor |
349 | * Surface heating to dry | ||
350 | * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion | ||
![]() |
29.2 | 351 | |
![]() |
67.2 | 352 | == 6.2 Specification == |
![]() |
65.2 | 353 | |
![]() |
67.2 | 354 | |
![]() |
65.2 | 355 | * Detect if there is rain or snow |
356 | * Input Power: DC 12 ~~ 24v | ||
357 | * Interface: RS485 | ||
358 | * Working Temperature: -30℃ ~~ 70℃ | ||
359 | * Working Humidity: 10 ~~ 90%RH | ||
360 | * Power Consumption: | ||
361 | ** No heating: 12mA @ 12v, | ||
362 | ** heating: 94ma @ 12v. | ||
363 | |||
![]() |
68.3 | 364 | == 6.3 Wiring == |
![]() |
29.2 | 365 | |
![]() |
68.3 | 366 | [[image:image-20250505193053-5.png||height="479" width="895"]] |
![]() |
29.2 | 367 | |
![]() |
68.3 | 368 | == 6.4 Dimension == |
![]() |
32.2 | 369 | |
370 | [[image:image-20250505144906-15.png]] | ||
371 | |||
372 | |||
![]() |
68.3 | 373 | == 6.5 Installation Notice == |
![]() |
32.2 | 374 | |
![]() |
67.2 | 375 | |
![]() |
65.2 | 376 | Do not power on while connect the cables. Double check the wiring before power on. |
![]() |
63.2 | 377 | |
![]() |
65.2 | 378 | Install with 15°degree. |
![]() |
32.2 | 379 | |
![]() |
65.2 | 380 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656056873783-780.png?rev=1.1||alt="1656056873783-780.png"]] |
![]() |
32.2 | 381 | |
![]() |
65.2 | 382 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656056883736-804.png?rev=1.1||alt="1656056883736-804.png"]] |
![]() |
32.2 | 383 | |
![]() |
68.3 | 384 | == 6.6 Heating == |
![]() |
32.2 | 385 | |
![]() |
67.2 | 386 | |
![]() |
76.1 | 387 | WSS-24 supports auto-heat feature. When the temperature is below the heat start temperature 15℃, WSS-24 starts to heat and stop at stop temperature (default is 25℃). |
![]() |
66.1 | 388 | |
389 | |||
![]() |
72.2 | 390 | = 7. WSS-23 ~-~- CO2/PM2.5/PM10 = |
![]() |
32.2 | 391 | |
![]() |
67.2 | 392 | |
![]() |
65.2 | 393 | WSS-23 is a RS485 Air Quality sensor. It can monitor CO2, PM2.5 and PM10 at the same time. |
![]() |
32.2 | 394 | |
![]() |
65.2 | 395 | WSS-23 uses weather proof shield which can make sure the sensors are well protected against UV & radiation. |
![]() |
34.1 | 396 | |
![]() |
67.2 | 397 | |
![]() |
65.2 | 398 | == 7.1 Feature == |
![]() |
47.1 | 399 | |
![]() |
67.2 | 400 | |
![]() |
65.2 | 401 | * RS485 CO2, PM2.5, PM10 sensor |
402 | * NDIR to measure CO2 with Internal Temperature Compensation | ||
403 | * Laser Beam Scattering to PM2.5 and PM10 | ||
![]() |
47.1 | 404 | |
![]() |
65.2 | 405 | == 7.2 Specification == |
![]() |
47.1 | 406 | |
![]() |
67.2 | 407 | |
![]() |
65.2 | 408 | * CO2 Range: 0 ~~ 5000ppm, accuracy: ±3%F•S(25℃) |
409 | * CO2 resolution: 1ppm | ||
410 | * PM2.5/PM10 Range: 0 ~~ 1000μg/m3 , accuracy ±3%F•S(25℃) | ||
411 | * PM2.5/PM10 resolution: 1μg/m3 | ||
412 | * Input Power: DC 7 ~~ 24v | ||
413 | * Preheat time: 3min | ||
414 | * Interface: RS485 | ||
415 | * Working Temperature: | ||
416 | ** CO2: 0℃ ~~ 50℃; | ||
417 | ** PM2.5/PM10: -30 ~~ 50℃ | ||
418 | * Working Humidity: | ||
419 | ** PM2.5/PM10: 15 ~~ 80%RH (no dewing) | ||
420 | ** CO2: 0 ~~ 95%RH | ||
421 | * Power Consumption: 50mA@ 12v. | ||
![]() |
47.1 | 422 | |
![]() |
68.3 | 423 | == 7.3 Wiring == |
![]() |
34.1 | 424 | |
![]() |
63.1 | 425 | [[image:image-20250505193033-4.png||height="376" width="689"]] |
![]() |
46.1 | 426 | |
![]() |
68.3 | 427 | == 7.4 Device Dimension == |
![]() |
46.1 | 428 | |
429 | |||
![]() |
65.2 | 430 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656056708366-230.png?rev=1.1||alt="1656056708366-230.png"]] |
![]() |
46.1 | 431 | |
432 | |||
![]() |
68.3 | 433 | == 7.5 Installation Notice == |
![]() |
65.2 | 434 | |
![]() |
67.2 | 435 | |
![]() |
65.2 | 436 | Do not power on while connect the cables. Double check the wiring before power on. |
437 | |||
438 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656056751153-304.png?rev=1.1||alt="1656056751153-304.png"]] | ||
439 | |||
440 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656056766224-773.png?rev=1.1||alt="1656056766224-773.png"]] | ||
441 | |||
442 | |||
![]() |
72.2 | 443 | = 8. WSS-22 ~-~- Integrated wind speed and direction sensor = |
![]() |
46.1 | 444 | |
445 | [[image:1746441120854-584.png||height="271" width="394"]] | ||
446 | |||
![]() |
65.2 | 447 | WSS-22 is a RS485 wind speed and wind direction monitor designed for weather station solution. |
![]() |
46.1 | 448 | |
![]() |
65.2 | 449 | WSS-22 shell is made of polycarbonate composite material, which has good anti-corrosion and anti-corrosion characteristics, and ensure the long-term use of the sensor without rust. At the same time, it cooperates with the internal smooth bearing system to ensure the stability of information collection |
450 | |||
451 | |||
452 | == 8.1 Feature == | ||
453 | |||
![]() |
68.3 | 454 | |
![]() |
65.2 | 455 | * RS485 wind speed / direction sensor |
456 | * PC enclosure, resist corrosion | ||
457 | |||
458 | == 8.2 Specification == | ||
459 | |||
![]() |
68.3 | 460 | |
![]() |
65.2 | 461 | * Wind speed range: 0 ~~ 60m/s |
462 | * Wind direction range: 0 ~~ 360° | ||
463 | * Start wind speed: ≤0.3 m/s | ||
464 | * Accuracy: ±(0.3+0.03V) m/s , ±1° | ||
465 | * Input Power: DC 5 ~~ 24v | ||
466 | * Interface: RS485 | ||
467 | * Working Temperature: -30℃ ~~ 70℃ | ||
468 | * Working Humidity: <100% (no dewing) | ||
![]() |
67.2 | 469 | * Power Consumption: 13mA @ 12v. |
![]() |
65.2 | 470 | * Cable Length: 2 meters |
471 | |||
![]() |
68.3 | 472 | == 8.3 Wiring == |
![]() |
46.1 | 473 | |
![]() |
63.1 | 474 | [[image:image-20250505192929-2.png||height="314" width="590"]] |
![]() |
46.1 | 475 | |
476 | |||
![]() |
68.3 | 477 | == 8.4 Device Dimension == |
![]() |
46.1 | 478 | |
![]() |
65.2 | 479 | (% class="wikigeneratedid" %) |
480 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/image-20220624152813-2.png?rev=1.1||alt="image-20220624152813-2.png"]] | ||
![]() |
46.1 | 481 | |
482 | |||
![]() |
68.3 | 483 | == 8.5 Angle Mapping == |
![]() |
46.1 | 484 | |
![]() |
68.3 | 485 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656056303845-585.png?rev=1.1||alt="1656056303845-585.png" height="455" width="476"]] |
![]() |
46.1 | 486 | |
487 | |||
![]() |
68.3 | 488 | == 8.6 Installation Notice == |
489 | |||
490 | |||
![]() |
65.2 | 491 | Do not power on while connect the cables. Double check the wiring before power on. |
492 | |||
493 | The sensor must be installed with below direction, towards North. | ||
494 | |||
![]() |
46.1 | 495 | [[image:1746441560175-162.png||height="304" width="484"]] |
496 | |||
497 | |||
![]() |
77.1 | 498 | = 9. WSS-21 ~-~- Rain Gauge = |
![]() |
46.1 | 499 | |
![]() |
67.2 | 500 | |
![]() |
65.2 | 501 | WSS-21 RS485 Rain Gauge is used in meteorology and hydrology to gather and measure the amount of liquid precipitation (mainly rainfall) over an area. |
![]() |
46.1 | 502 | |
![]() |
65.2 | 503 | WSS-21 uses a tipping bucket to detect rainfall. The tipping bucket use 3D streamline shape to make sure it works smoothly and is easy to clean. |
![]() |
46.1 | 504 | |
![]() |
65.2 | 505 | The tipping bucket of WSS-01 is adjusted to the best angle. When installation, user only needs to screw up and adjust the bottom horizontally. |
![]() |
46.1 | 506 | |
![]() |
65.2 | 507 | WSS-21 package includes screw which can be installed to ground. If user want to install WSS-21 on pole, they can purchase WS-K2 bracket kit. |
508 | |||
![]() |
67.2 | 509 | |
![]() |
65.2 | 510 | == 9.1 Feature == |
511 | |||
![]() |
68.3 | 512 | |
![]() |
65.2 | 513 | * RS485 Rain Gauge |
514 | * Small dimension, easy to install | ||
515 | * Vents under funnel, avoid leaf or other things to avoid rain flow. | ||
516 | * ABS enclosure. | ||
517 | * Horizontal adjustable. | ||
518 | |||
519 | == 9.2 Specification == | ||
520 | |||
![]() |
68.3 | 521 | |
![]() |
46.1 | 522 | * Resolution: 0.2mm |
![]() |
65.2 | 523 | * Accuracy: ±3% |
524 | * Range: 0 ~~ 100mm | ||
525 | * Rainfall strength: 0mm ~~ 4mm/min (max 8mm/min) | ||
526 | * Input Power: DC 5 ~~ 24v | ||
527 | * Interface: RS485 | ||
528 | * Working Temperature: 0℃ ~~ 70℃ (incorrect below 0 degree, because water become ICE) | ||
529 | * Working Humidity: <100% (no dewing) | ||
530 | * Power Consumption: 4mA @ 12v. | ||
![]() |
46.1 | 531 | |
![]() |
65.2 | 532 | == 9.3 Wiring == |
![]() |
46.1 | 533 | |
![]() |
63.1 | 534 | [[image:image-20250505192952-3.png||height="305" width="581"]] |
![]() |
46.1 | 535 | |
536 | |||
![]() |
68.3 | 537 | == 9.4 Dimension == |
![]() |
46.1 | 538 | |
539 | |||
540 | [[image:image-20250505184528-20.png||height="468" width="471"]] | ||
541 | |||
542 | [[image:image-20250505185334-22.png||height="533" width="470"]] | ||
![]() |
65.2 | 543 | |
![]() |
68.3 | 544 | == 9.5 Installation Notice == |
![]() |
65.2 | 545 | |
546 | |||
547 | ((( | ||
548 | Do not power on while connect the cables. Double check the wiring before power on. | ||
549 | ))) | ||
550 | |||
551 | ((( | ||
552 | Installation Photo as reference: | ||
553 | ))) | ||
554 | |||
555 | |||
556 | ((( | ||
557 | (% style="color:#4472c4" %)** Install on Ground:** | ||
558 | ))) | ||
559 | |||
560 | ((( | ||
561 | WSS-21 Rain Gauge include screws so can install in ground directly . | ||
562 | ))) | ||
563 | |||
564 | |||
565 | ((( | ||
566 | (% style="color:#4472c4" %)** Install on pole:** | ||
567 | ))) | ||
568 | |||
569 | ((( | ||
570 | If user want to install on pole, they can purchase the (% style="color:#4472c4" %)** WS-K2 : Bracket Kit for Pole installation**(%%), and install as below: | ||
571 | |||
572 | [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/image-20220624152218-1.png?width=276&height=526&rev=1.1||alt="image-20220624152218-1.png"]] | ||
573 | |||
574 | WS-K2: Bracket Kit for Pole installation | ||
575 | |||
![]() |
83.1 | 576 | WS-K2 dimension document, please see: |
![]() |
65.2 | 577 | ))) |
578 | |||
579 | [[https:~~/~~/www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0>>https://www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0]] | ||
![]() |
75.1 | 580 | |
581 | |||
582 |