8 -= **1. Actility Thingpark Enterprise** =
8 += 1. Actility Thingpark Enterprise =
9 9  
10 -== **1.1 Introduction** ==
10 +== 1.1 Introduction ==
11 11  
12 -=== **1.1.1 What is Actility Thingpark Enterprise** ===
12 +=== 1.1.1 What is Actility Thingpark Enterprise ===
13 13  
14 14  
15 -//ThingPark Enterprise is an IoT connectivity management solution allowing to the deployment of a dedicated and fully controlled LoRaWAN® network for a fast use case enablement. All components of the network, including sensors, gateways, and data routing are managed from a unique and easy-to-use user interface. The ThingPark Enterprise allows full flexibility in the choice of gateways or devices. It is also a flexible, scalable, and secure solution allowing to start with a Proof-of-Concept (POC) and scale to full deployments.//
15 +ThingPark Enterprise is an IoT connectivity management solution allowing to the deployment of a dedicated and fully controlled LoRaWAN® network for a fast use case enablement. All components of the network, including sensors, gateways, and data routing are managed from a unique and easy-to-use user interface. The ThingPark Enterprise allows full flexibility in the choice of gateways or devices. It is also a flexible, scalable, and secure solution allowing to start with a Proof-of-Concept (POC) and scale to full deployments.
16 16  
17 17  
18 -= **2. Gateway Registration for Basics Station** =
18 += 2. Gateway Registration for Basics Station =
19 19  
20 -== **2.1 Introduction** ==
20 +== 2.1 Introduction ==
21 21  
22 22  
23 -//The LoRa Basics™ Station protocol simplifies the management of large-scale LoRaWAN networks. [[The LoRa Basics Station doc>>url:https://www.thethingsindustries.com/docs/gateways/lora-basics-station/]]//
23 +The LoRa Basics™ Station protocol simplifies the management of large-scale LoRaWAN networks. [[The LoRa Basics Station doc>>url:https://www.thethingsindustries.com/docs/gateways/lora-basics-station/]]
24 24  
25 25  
26 26  (% style="color:blue" %)**Below list the support products and Requirements:**
27 27  
28 -1. //LoRaWAN Gateway model: [[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]]//
29 -1. //Firmware version since:[[lgw~~-~~-build-v5.4.1651822913>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Test_Firmware/lgw--build-v5.4.1651822913-20220506-1543/]]//
28 +1. LoRaWAN Gateway model: [[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]]
29 +1. Firmware version since: [[lgw~~-~~-build-v5.4.1651822913>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Test_Firmware/lgw--build-v5.4.1651822913-20220506-1543/]]
30 30  
31 -
32 32  (% style="color:blue" %)**What do you need to prepare**
33 33  
34 -//A gateway that can access the internet normally//
33 +A gateway that can access the internet normally
35 35  
36 36  
37 -== **2.2 Step 1. Add Gateway** ==
36 +== 2.2 Step 1. Add Gateway ==
38 38  
39 39  
40 40  [[image:image-20220531084235-1.png||height="767" width="1332"]]
... ... @@ -55,28 +55,27 @@
55 55  [[image:image-20220610095043-1.png]]
56 56  
57 57  
58 -(% style="color:blue" %)**//Have need to put in latitude and longitude, and then click "CREATE".//**
57 +(% style="color:blue" %)**Have need to put in latitude and longitude, and then click "CREATE".**
59 59  
60 60  [[image:image-20220531085325-12.png]]
61 61  
62 62  
63 63  
64 -== **2.3 Step 2. Access the gateway GUI** ==
63 +== 2.3 Step 2. Access the gateway GUI ==
65 65  
66 66  
67 -//Users need to update the API key and install the Certificate//
66 +Users need to update the API key and install the Certificate
68 68  
69 69  
70 70  [[image:image-20220531084451-4.png||height="683" width="1357"]]
71 71  
72 72  
72 +== 2.4 Step 3. Configure Station ==
73 73  
74 -== **2.4 Step 3. Configure Station** ==
75 75  
75 +Users need to input Server URI, as well as install the CUPS certificate.
76 76  
77 -//Users need to input Server URI, as well as install the CUPS certificate.//
78 78  
79 -
80 80  (% style="color:blue" %)**Just to clarify.**
81 81  
82 82  (% class="box" %)
... ... @@ -93,16 +93,16 @@
93 93  Configure the gateway
94 94  
95 95  
96 -== **2.5 Start Station** ==
94 +== 2.5 Start Station ==
97 97  
98 98  
99 -//When the user has finished the configuration, Please click Sace&Apply to start station to connect Actility Thingpark Enterprise.//
97 +When the user has finished the configuration, Please click Sace&Apply to start station to connect Actility Thingpark Enterprise.
100 100  
101 101  
102 -== **2.6 Successful Connection** ==
100 +== 2.6 Successful Connection ==
103 103  
104 104  
105 -//If users complete the above steps, which will see the live date in the Actility Thingpark Enterprise.//
103 +If users complete the above steps, which will see the live date in the Actility Thingpark Enterprise.
106 106  
107 107  
108 108  [[image:image-20220531084632-6.png||height="700" width="1403"]]
... ... @@ -115,33 +115,33 @@
115 115  
116 116  
117 117  
118 -== **2.7 Trouble Shooting** ==
116 +== 2.7 Trouble Shooting ==
119 119  
118 +=== 2.7.1 How do users view Basic Station logs and Record logs ===
120 120  
121 -=== **2.7.1 How do users view Basic Station logs and Record logs** ===
122 122  
123 -//Users can check the station log on the logread/system log page.//
121 +Users can check the station log on the logread/system log page.
124 124  
125 125  
126 -//Station Log~://
124 +**Station Log:**
127 127  
128 128  [[image:image-20220531085014-10.png]]
129 129  
130 130  
131 131  
132 -//and recode the station log on the system/Recode log page.//
130 +**and recode the station log on the system/Recode log page.**
133 133  
134 134  [[image:image-20220531084931-9.png]]
135 135  
136 -//Recore Log//
134 +**Recore Log**
137 137  
138 138  
139 -=== **2.7.2 How to solve the problem when "(400) TC credentials not found" is displayed in the log** ===
137 +=== 2.7.2 How to solve the problem when "(400) TC credentials not found" is displayed in the log ===
140 140  
141 141  
142 142  In this case, the user needs to check whether the Gateway ID matches the UUID on Actility Thingpark.
143 143  
144 -In addition, the user needs to regenerate new certificates in ThingPark GUI **(Advanced tab of the Base Station panel)**.
142 +In addition, the user needs to regenerate new certificates in ThingPark GUI **(Advanced tab of the Base Station panel)**, Then wait 2-3 minutes to refresh the ThingPark GUI to see if the gateway is online.
145 145  
146 146  [[image:image-20220822085416-2.png]]
147 147  
... ... @@ -151,13 +151,25 @@
151 151  
152 152  
153 153  (((
154 -//The reason of fail to join Actility is that our end node use (% style="color:blue" %)**RX2DR=3**(%%) for join. this is the default setting for TTN and many LoRaWAN servers.//
152 +The reason of fail to join Actility is that our end node use (% style="color:blue" %)**RX2DR=3**(%%) for join. this is the default setting for TTN and many LoRaWAN servers.
155 155  )))
156 156  
157 157  (((
158 -//The Actility use (% style="color:blue" %)**RX2DR=0**(%%) for Join, when Actility sends a Join Accept, due to RX2DR different, the end node can not receive the Join Accept message from Actility so keep joining.//
156 +The Actility use (% style="color:blue" %)**RX2DR=0**(%%) for Join, when Actility sends a Join Accept, due to RX2DR different, the end node can not receive the Join Accept message from Actility so keep joining.
159 159  )))
160 160  
161 161  (((
162 -//Some of End Nodes already support the change on RX2DR for OTAA join, in this case, use need to write AT+RX2DR=0. Please contact Dragino support for more info if the product doesn't support it.//
160 +Some of End Nodes already support the change on RX2DR for OTAA join, in this case, use need to write AT+RX2DR=0. Please contact Dragino support for more info if the product doesn't support it.
161 +
162 +=== 2.7.2 When all the parameters of the device are filled in correctly, it still cannot join the network ===
163 +
164 +You can not choose the preset template and use the general settings to eliminate the interference caused by the preset template
165 +
166 +[[image:image-20230510101636-1.png]]
167 +
168 +**error**
169 +
170 +[[image:image-20230510101714-3.png]]
171 +
172 +**right**
163 163  )))
image-20230510101636-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +45.6 KB
Content
image-20230510101648-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +40.1 KB
Content
image-20230510101714-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +41.5 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0