<
From version < 16.1 >
edited by Xiaoling
on 2022/05/25 09:47
To version < 8.2 >
edited by Xiaoling
on 2022/05/24 16:33
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -2,87 +2,74 @@
2 2  
3 3  {{toc/}}
4 4  
5 -= **1. Actility Thingpark Enterprise** =
5 += 1. Actility Thingpark Enterprise =
6 6  
7 -== **1.1 Introduction** ==
7 +== 1.1 Introduction ==
8 8  
9 -=== **1.1.1 What is Actility Thingpark Enterprise** ===
9 +=== 1.1.1 What is Actility Thingpark Enterprise ===
10 10  
11 +ThingPark Enterprise is an IoT connectivity management solution allowing to deploy a dedicated and fully controlled LoRaWAN® network for a fast use case enablement. All components of the network, including sensors, gateways and data routing are managed from a unique and easy-to-use user interface. The ThingPark Enterprise allows full flexibility in the choice of gateways or devices. It is also a flexible, scalable and secure solution allowing to start with a Proof-of-Concept (PoC) and scale to full deployments.
11 11  
12 -//ThingPark Enterprise is an IoT connectivity management solution allowing to the deployment of a dedicated and fully controlled LoRaWAN® network for a fast use case enablement. All components of the network, including sensors, gateways, and data routing are managed from a unique and easy-to-use user interface. The ThingPark Enterprise allows full flexibility in the choice of gateways or devices. It is also a flexible, scalable, and secure solution allowing to start with a Proof-of-Concept (POC) and scale to full deployments.//
13 += 2. Gateway Registration for Basics Station =
13 13  
15 +== 2.1 Introduction ==
14 14  
15 -= **2. Gateway Registration for Basics Station** =
17 +The LoRa Basics™ Station protocol simplifies management of large scale LoRaWAN networks. [[The LoRa Basics Station doc>>url:https://www.thethingsindustries.com/docs/gateways/lora-basics-station/]]
16 16  
17 -== **2.1 Introduction** ==
18 -
19 -
20 -//The LoRa Basics™ Station protocol simplifies the management of large-scale LoRaWAN networks. [[The LoRa Basics Station doc>>url:https://www.thethingsindustries.com/docs/gateways/lora-basics-station/]]//
21 -
22 -
23 23  **Below list the support products and Requirements:**
24 24  
25 -1. //LoRaWAN Gateway model: [[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]]//
26 -1. //Firmware version since:[[lgw~~-~~-build-v5.4.1651822913>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Test_Firmware/lgw--build-v5.4.1651822913-20220506-1543/]]//
21 +1. LoRaWAN Gateway model: [[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]]
27 27  
23 +1. Firmware version since :[[lgw~~-~~-build-v5.4.1651822913>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Test_Firmware/lgw--build-v5.4.1651822913-20220506-1543/]]
28 28  
29 29  **What do you need to prepare**
30 30  
31 -//A gateway that can access the internet normally//
27 +A gateway that can access the internet normally
32 32  
29 +== 2.2 Step 1. Add Gateway ==
33 33  
34 -== **2.2 Step 1. Add Gateway** ==
35 -
36 36  [[image:image-20220524163104-1.png]]
37 37  
33 +Add Gateway_1
38 38  
39 -
40 40  **The following items need to be configured:**
41 41  
42 42  (% class="box" %)
43 43  (((
44 -// 1.Model               **~-~->** Choose the Model
45 - 2.Name                **~-~->** Custom
46 - 3.LRR-UUID  **~-~->** **0061C0(aways is it)**-Gateway EUI //
47 -
48 -// Such as: **0016C0-A840411E96744150**//
49 -// 4.RF Region  **~-~->** Choose the frequency//
39 + 1.Model                **~-~->** Choose the Model
40 + 2.Name                 **~-~->** Custom
41 + 3.LRR-UUID  **~-~->** Enter 0061C0-Gateway EUI ,Such as:0016C0-A840411E96744150
42 + 4.RF Region  **~-~->** Choose the frequency
50 50  )))
51 51  
52 52  [[image:image-20220524163206-2.png]]
53 53  
47 +Add Gateway_2
54 54  
49 +Have need to put in latitude and longitude, and then click **"CREATE"**.
55 55  
56 -**//Have need to put in latitude and longitude, and then click "CREATE".//**
57 -
58 58  [[image:image-20220524163234-3.png]]
59 59  
53 +Add Gateway_3
60 60  
55 +== 2.3 Step 2. Access the gateway GUI ==
61 61  
62 -== **2.3 Step 2. Access the gateway GUI** ==
57 +User need to update the API key and install the Certificate
63 63  
64 -
65 -//Users need to update the API key and install the Certificate//
66 -
67 -
68 68  [[image:image-20220524163255-4.png]]
69 69  
61 +Access the gateway GUI
70 70  
71 -== **2.4 Step 3. Configure Station** ==
63 +== 2.4 Step 3. Configure Station ==
72 72  
65 +User need to input Server URI, as well as install CUPS certificate.
73 73  
74 -//Users need to input Server URI, as well as install the CUPS certificate.//
67 +**just to clarify.**
75 75  
76 -
77 -**Just to clarify.**
78 -
79 79  (% class="box" %)
80 80  (((
81 -//CUPS Server URI **~-~->**  Server Adress//
82 -
83 -// Such as:[[https:~~/~~/community.thingpark.io:443>>url:https://community.thingpark.io/||style="background-color: rgb(250, 250, 250);"]]//
84 -
85 -//CUPS certificate **~-~->**  server certificate **(user can use the button to install the certificate by default)**//
71 +CUPS Server URI **~-~->**  Server Adress Such as:[[https:~~/~~/community.thingpark.io:443>>url:https://community.thingpark.io/||style="background-color: rgb(250, 250, 250);"]]
72 +CUPS certificate **~-~->**  Server CA(user can use the button to install the certificate by default)
86 86  )))
87 87  
88 88  [[image:image-20220524163334-5.png]]
... ... @@ -89,51 +89,44 @@
89 89  
90 90  Configure the gateway
91 91  
79 +== 2.5 Start Station ==
92 92  
93 -== **2.5 Start Station** ==
81 +When the user has finished the configuration,Please click Sace&Apply to start station to connect Actility Thingpark Enterprise.
94 94  
95 -//When the user has finished the configuration, Please click Sace&Apply to start station to connect Actility Thingpark Enterprise.//
83 +== 2.6 Siccessful Connection ==
96 96  
97 -== **2.6 Successful Connection** ==
85 +If user completes the above steps,which will see live date in the Actility Thingpark Enterprise.
98 98  
87 +[[image:https://wiki.dragino.com/images/thumb/b/b4/View_gateway_thingpark.png/600px-View_gateway_thingpark.png||height="297" width="600"]]
99 99  
100 -//If users complete the above steps, which will see the live date in the Actility Thingpark Enterprise.//
89 +Station live date
101 101  
91 +[[image:https://wiki.dragino.com/images/thumb/4/40/Gateway_status_thingpark.png/600px-Gateway_status_thingpark.png||height="285" width="600"]]
102 102  
103 -[[image:image-20220524163358-6.png]]
93 +Station live date
104 104  
95 +== 2.7 Trouble Shooting ==
105 105  
97 +User can check the station log in the logread/system log page.
106 106  
107 -//Station live date//
99 +[[image:https://wiki.dragino.com/images/thumb/7/7c/Station_log_xiao.png/600px-Station_log_xiao.png||height="457" width="600"]]
108 108  
109 -[[image:image-20220524163420-7.png]]
101 +Station Log
110 110  
103 +and recode the station log in the system/Recode log page.
111 111  
112 -== **2.7 Trouble Shooting** ==
105 +[[image:https://wiki.dragino.com/images/thumb/5/50/Recore_log_xiao.png/600px-Recore_log_xiao.png||height="147" width="600"]]
113 113  
107 +Recore Log
114 114  
115 -//Users can check the station log on the logread/system log page.//
116 -
117 -
118 -//Station Log~://
119 -
120 -[[image:image-20220524163455-8.png]]
121 -
122 -
123 -//and recode the station log on the system/Recode log page.//
124 -
125 -[[image:image-20220524163528-10.png]]
126 -
127 -//Recore Log//
128 -
129 129  (((
130 -//The reason of fail to join Actility is that our end node use RX2DR=3 for join. this is the default setting for TTN and many LoRaWAN servers.//
110 +The reason of fail to join Actility is that our end node use RX2DR=3 for join. this is the default setting for TTN and many LoRaWAN servers.
131 131  )))
132 132  
133 133  (((
134 -//The Actility use RX2DR=0 for Join, when Actility sends a Join Accept, due to RX2DR different, the end node can not receive the Join Accept message from Actility so keep joining.//
114 +The Actility use RX2DR=0 for Join, when Actility sends a Join Accept, due to RX2DR different, the end node can not receive the Join Accept message from Actility so keep joining.
135 135  )))
136 136  
137 137  (((
138 -//Some of End Nodes already support the change on RX2DR for OTAA join, in this case, use need to write AT+RX2DR=0. Please contact Dragino support for more info if the product doesn't support it.//
118 +Some of End Nodes already support the change on RX2DR for OTAA join, in this case, use need to write AT+RX2DR=0. Please contact Dragino support for more info if the product doesn't support it.
139 139  )))
image-20220524163358-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -33.2 KB
Content
image-20220524163420-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -34.7 KB
Content
image-20220524163455-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -130.1 KB
Content
image-20220524163519-9.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -25.0 KB
Content
image-20220524163528-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -25.0 KB
Content
image-20220525094736-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -51.1 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0