Wiki source code of AI Image Sensor Calibration

Version 183.1 by Karry Zhuang on 2024/07/09 14:08

Hide last authors
Karry Zhuang 178.1 1 **Table of Contents:**
2
3 {{toc/}}
4
Edwin Chen 2.1 5
6
7
Karry Zhuang 28.1 8
Edwin Chen 2.1 9
10
11
12
Edwin Chen 1.1 13 = 1. Overview =
14
Xiaoling 179.3 15
Karry Zhuang 27.1 16 AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. 
Karry Zhuang 26.1 17
Xiaoling 179.3 18
Edwin Chen 1.1 19 = 2. Calibrate Digits Readings =
20
Xiaoling 179.3 21
Karry Zhuang 182.1 22 The factory default firmware of AIS Sensor is a digital wheel dial. It is recommended that the distance between the camera and the digital wheel dial be 3cm-7cm when installing AIS Sensor. Because the distance is too far, the camera's flash will not be able to illuminate the digital wheel dial to obtain readings.
Karry Zhuang 180.1 23
Karry Zhuang 181.1 24 If you are using a [[pointer type dial>>http://wiki.dragino.com/xwiki/bin/view/Main/AI%20Image%20Sensor%20Calibration/#H2.5PressurePointerMeterCalibration]], just adjust the camera to fully see the entire dial.
Karry Zhuang 180.1 25
Karry Zhuang 176.1 26 According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>url:https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]].
Karry Zhuang 58.2 27
Karry Zhuang 176.1 28 Firmware upgrade Reference:[[Update Firmware for the AI Sensors>>http://wiki.dragino.com/xwiki/bin/view/Main/Update%20Firmware%20for%20AI%20Sensor/]].
29
Xiaoling 179.3 30
Edwin Chen 1.1 31 == 2.1 Calibrate a Water Meter ==
32
33 === 2.1.1 Introduce ===
34
Xiaoling 179.3 35
Karry Zhuang 26.1 36 This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
37
Xiaoling 179.3 38
Karry Zhuang 90.2 39 === 2.1.2 Fix Sensor to a Water Meter ===
Edwin Chen 1.1 40
Xiaoling 179.3 41
Karry Zhuang 113.1 42 The assembly necessitates the use of two screws, two spacers, and this specific device.
Edwin Chen 1.1 43
Karry Zhuang 113.1 44 Additionally, there are AIS Sensors available along with AUC USB TTL adapters for AIS Sensors.
45
Edwin Chen 81.2 46 The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]].
47
Karry Zhuang 90.2 48 [[image:image-20240428163842-3.png||height="425" width="609"]] [[image:image-20240428155254-1.png||height="424" width="358"]]
49
50 The procedure is as follows:
51
Karry Zhuang 92.4 52 ~1. Secure back of the AIS sensor  onto the small board and adjust its position according to your requirements. You may use two additional screws for fixation or utilize 3M double-sided adhesive for attachment.
Karry Zhuang 90.2 53
54 [[image:image-20240428165320-4.gif]]
55
Xiaoling 179.3 56
Karry Zhuang 90.2 57 2. Proceed by fastening the device using the previously prepared screws and gaskets.
58
59 [[image:image-20240428165354-5.gif]]
60
Xiaoling 179.3 61
Karry Zhuang 90.2 62 3. Finally, nestle the device onto your water meter, ensuring that it can be adjusted to meet your specific needs while guaranteeing that the camera is directed towards the digital wheel face.
63
64 [[image:image-20240428165412-6.gif]].
65
Xiaoling 179.3 66
Karry Zhuang 92.2 67 The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
Karry Zhuang 90.2 68
Karry Zhuang 92.2 69 [[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]]
Karry Zhuang 90.2 70
71
Xiaoling 179.3 72 === 2.1.3 Calibration ===
Karry Zhuang 90.2 73
74
Karry Zhuang 157.1 75 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
Karry Zhuang 26.1 76
Karry Zhuang 175.1 77 For example, Select the corresponding serial port number, here 14.
Karry Zhuang 56.5 78
Karry Zhuang 26.1 79 (% class="box warningmessage" %)
80 (((
Karry Zhuang 79.2 81 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
Karry Zhuang 26.1 82 )))
83
Xiaoling 179.3 84 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]]
Karry Zhuang 26.1 85
Xiaoling 179.3 86 (% title="Click and drag to resize" %)​
Karry Zhuang 26.1 87
Xiaoling 179.3 88 Next, select a Baud rate of **921600** and click on **"start"**. Then, click on **"show full image" **to display the camera screen.
Karry Zhuang 26.1 89
Xiaoling 179.3 90 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]]
Karry Zhuang 26.1 91
Xiaoling 179.3 92 (% title="Click and drag to resize" %)​
93
94 Click **"enable Raw" **and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
95
Karry Zhuang 45.3 96 (% aria-label="image-20240419175324-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-8.png||data-widget="image" height="637" width="911"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 97
Karry Zhuang 45.3 98 (% aria-label="image-20240419175324-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-9.png||data-widget="image" height="348" width="913"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 99
Karry Zhuang 27.1 100 This water meter has only five fields, and the coordinates of the digital roulette wheel are shown in the figure.
Karry Zhuang 26.1 101
Karry Zhuang 27.1 102 If your device's digital scroll wheel dial does not match these five fields, you can try the other field dial coordinate dot plots in 2.4.
Karry Zhuang 26.1 103
Karry Zhuang 45.3 104 (% aria-label="1713573839396-314.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713573839396-314.png||data-widget="image" height="198" width="649"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 105
Karry Zhuang 56.3 106 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
Karry Zhuang 26.1 107
Xiaoling 179.3 108 (% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]]
Karry Zhuang 26.1 109
Xiaoling 179.3 110 (% title="Click and drag to resize" %)​
111
Karry Zhuang 27.1 112 Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
Karry Zhuang 29.1 113
Karry Zhuang 27.1 114 The "Long dial" option is the long hand dial.
Karry Zhuang 29.1 115
Karry Zhuang 27.1 116 The "Short dial" option is the short pointer and digital wheel dial.
Karry Zhuang 29.1 117
Karry Zhuang 27.1 118 The "Digit wheel" option is the digital wheel dial.
Karry Zhuang 29.1 119
Karry Zhuang 27.1 120 Now we are calibrating the digital wheel face of the water meter. Here we select "digit wheel".
Karry Zhuang 26.1 121
Karry Zhuang 45.3 122 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 123
Karry Zhuang 29.1 124 1:Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
Karry Zhuang 26.1 125
Karry Zhuang 45.2 126 2: Fill in the number of number wheel on their dial,fi;
Karry Zhuang 26.1 127
Karry Zhuang 27.1 128 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
Karry Zhuang 26.1 129
Karry Zhuang 27.1 130 4: Preview whether the setting of their coordinates is accurate;
Karry Zhuang 26.1 131
Karry Zhuang 27.1 132 5: Click to write all configuration to AIS;
Karry Zhuang 26.1 133
Karry Zhuang 27.1 134 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
Karry Zhuang 26.1 135
Karry Zhuang 45.3 136 (% aria-label="1713576930301-479.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576930301-479.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 137
Karry Zhuang 27.1 138 The effect can be previewed by clicking the "Preview correction" button as shown below.
Karry Zhuang 26.1 139
Karry Zhuang 27.1 140 (% aria-label="1713577029535-253.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577029535-253.png||data-widget="image" height="748" width="1069"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 141
142
Karry Zhuang 27.1 143 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
Karry Zhuang 26.1 144
Karry Zhuang 45.2 145 (% aria-label="1713577072196-132.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577072196-132.png||data-widget="image" height="751" width="1073"]]
Karry Zhuang 26.1 146
Karry Zhuang 45.2 147 (% title="Click and drag to resize" %)​
148
Karry Zhuang 58.4 149 == 2.2 Calibration Power Meter ==
Karry Zhuang 26.1 150
Karry Zhuang 30.1 151 === 2.2.1 Introduce ===
152
Xiaoling 179.3 153
Karry Zhuang 39.2 154 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
Karry Zhuang 30.1 155
156
Xiaoling 179.3 157 === 2.2.2 Fix Sensor to a Power Meter ===
158
159
Karry Zhuang 93.2 160 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
Karry Zhuang 30.1 161
Karry Zhuang 102.1 162 [[image:image-20240429091325-1.png||height="706" width="535"]]
Karry Zhuang 30.1 163
Xiaoling 179.3 164
Karry Zhuang 30.1 165 === 2.2.3 Calibration ===
166
Xiaoling 179.3 167
Karry Zhuang 158.1 168 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
Karry Zhuang 30.1 169
Karry Zhuang 175.1 170 For example, Select the corresponding serial port number, here 14.
Karry Zhuang 56.5 171
Karry Zhuang 30.1 172 (% class="box warningmessage" %)
173 (((
Karry Zhuang 158.1 174 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
Karry Zhuang 30.1 175 )))
176
Xiaoling 179.3 177 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]]
Karry Zhuang 30.1 178
Xiaoling 179.3 179 (% title="Click and drag to resize" %)​
Karry Zhuang 30.1 180
Xiaoling 179.3 181 Next, select a Baud rate of **921600** and click on **"start"**. Then, click on **"show full image"** to display the camera screen.
182
Karry Zhuang 49.2 183 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:image-20240420135207-3.png||height="485" width="706"]]
Karry Zhuang 39.2 184
185
Xiaoling 179.3 186 Click **"enable Raw"** and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
187
Karry Zhuang 41.2 188 [[image:1713592384928-500.png||height="494" width="266"]][[image:image-20240420141955-4.png||height="492" width="782"]]
Karry Zhuang 39.2 189
Karry Zhuang 41.2 190 This power meter has only six fields, and the coordinates of the digital roulette wheel are shown in the figure.
Karry Zhuang 39.2 191
Karry Zhuang 41.2 192 If your device's digital scroll wheel dial does not match these six fields, you can try the other field dial coordinate dot plots in 2.4.
Karry Zhuang 39.2 193
Karry Zhuang 41.2 194 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="148" width="588"]]
Karry Zhuang 39.2 195
Karry Zhuang 56.3 196 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
Karry Zhuang 41.2 197
Karry Zhuang 51.2 198 [[image:image-20240420153316-11.png||height="569" width="755"]]
Karry Zhuang 39.2 199
Xiaoling 179.3 200
Karry Zhuang 41.3 201 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
202
203 The "Long dial" option is the long hand dial.
204
205 The "Short dial" option is the short pointer and digital wheel dial.
206
207 The "Digit wheel" option is the digital wheel dial.
208
209 Now we are calibrating the digital wheel face of the power meter. Here we select "digit wheel".
210
Karry Zhuang 45.3 211 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 41.3 212
213 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
214
Karry Zhuang 45.2 215 2: Fill in the number of number wheel on their dial,six;
Karry Zhuang 41.3 216
217 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
218
219 4: Preview whether the setting of their coordinates is accurate;
220
221 5: Click to write all configuration to AIS;
222
223 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
224
Karry Zhuang 45.2 225 [[image:image-20240420143939-6.png||height="408" width="886"]](% title="Click and drag to resize" %)​
Karry Zhuang 41.3 226
227 The effect can be previewed by clicking the "Preview correction" button as shown below.
228
Karry Zhuang 45.2 229 [[image:image-20240420144154-7.png||height="534" width="880"]]
Karry Zhuang 41.3 230
Karry Zhuang 45.2 231 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
Karry Zhuang 41.3 232
Karry Zhuang 45.2 233 [[image:1713595371004-125.png]]
Karry Zhuang 41.3 234
235
Karry Zhuang 58.4 236 == 2.3 Calibration Gas Meter ==
Karry Zhuang 26.1 237
Karry Zhuang 47.2 238 === 2.3.1 Introduce ===
Karry Zhuang 45.4 239
Xiaoling 179.3 240
Karry Zhuang 47.2 241 This gas meter uses G2.5 membrane gas meter. It features eight dial numbers for measurement accuracy.
Karry Zhuang 45.4 242
Xiaoling 179.3 243
Karry Zhuang 47.2 244 === 2.3.2 Fix Sensor to a Gas Meter ===
Karry Zhuang 45.4 245
Xiaoling 179.3 246
Karry Zhuang 96.1 247 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
Karry Zhuang 45.4 248
Karry Zhuang 102.1 249 [[image:image-20240429092436-2.png||height="676" width="519"]]
Karry Zhuang 45.4 250
Karry Zhuang 99.1 251
Karry Zhuang 62.1 252 === 2.3.3 Calibration ===
Karry Zhuang 47.2 253
Xiaoling 179.3 254
Karry Zhuang 158.1 255 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
Karry Zhuang 47.2 256
Karry Zhuang 175.1 257 For example, Select the corresponding serial port number, here 14.
Karry Zhuang 56.5 258
Karry Zhuang 47.2 259 (% class="box warningmessage" %)
260 (((
Karry Zhuang 158.1 261 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
Karry Zhuang 47.2 262 )))
263
264 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
265
266 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
267
Karry Zhuang 49.2 268 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:1713598021017-402.png]]
Karry Zhuang 47.2 269
Karry Zhuang 49.2 270 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
Karry Zhuang 47.2 271
Karry Zhuang 49.2 272 [[image:1713592384928-500.png||height="494" width="266"]][[image:1713598094208-496.png||height="494" width="790"]]
Karry Zhuang 47.2 273
Karry Zhuang 56.4 274 This gas meter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure.
Karry Zhuang 47.2 275
Karry Zhuang 49.2 276 If your device's digital scroll wheel dial does not match these eight fields, you can try the other field dial coordinate dot plots in 2.4.
Karry Zhuang 47.2 277
Karry Zhuang 49.2 278 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image" height="113" width="542"]]
Karry Zhuang 47.2 279
Karry Zhuang 56.3 280 (% id="cke_bm_196694S" style="display:none" %) (%%)The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
Karry Zhuang 47.2 281
Karry Zhuang 50.2 282 [[image:image-20240420153139-10.png||height="530" width="710"]]
Karry Zhuang 49.2 283
Karry Zhuang 50.2 284 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
Karry Zhuang 49.2 285
Karry Zhuang 50.2 286 The "Long dial" option is the long hand dial.
Karry Zhuang 49.2 287
Karry Zhuang 50.2 288 The "Short dial" option is the short pointer and digital wheel dial.
289
290 The "Digit wheel" option is the digital wheel dial.
291
Karry Zhuang 56.4 292 Now we are calibrating the digital wheel face of the gas meter. Here we select "digit wheel".
Karry Zhuang 50.2 293
294 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]]
295
Karry Zhuang 54.2 296 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
Karry Zhuang 50.2 297
Karry Zhuang 54.2 298 2: Fill in the number of number wheel on their dial,eight;
Karry Zhuang 50.2 299
Karry Zhuang 54.2 300 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
Karry Zhuang 50.2 301
Karry Zhuang 54.2 302 4: Preview whether the setting of their coordinates is accurate;
303
304 5: Click to write all configuration to AIS;
305
306 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
307
308 [[image:image-20240420154023-12.png||height="436" width="942"]](% title="Click and drag to resize" %)​
309
310 The effect can be previewed by clicking the "Preview correction" button as shown below.
311
312 [[image:1713598855240-454.png]]
313
314 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
315
Karry Zhuang 104.1 316 [[image:1714358288601-933.png]]
Karry Zhuang 54.2 317
Xiaoling 179.3 318
Karry Zhuang 27.1 319 == 2.4 Digital wheel dial take point coordinate diagram ==
Karry Zhuang 26.1 320
Xiaoling 179.3 321
Karry Zhuang 27.1 322 4  numbers:
Karry Zhuang 26.1 323
Karry Zhuang 27.1 324 (% aria-label="image-20240420094632-11.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-11.png||data-widget="image" height="134" width="410"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 325
Karry Zhuang 27.1 326 5 numbers:
Karry Zhuang 26.1 327
Karry Zhuang 27.1 328 (% aria-label="image-20240420094632-12.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-12.png||data-widget="image" height="130" width="427"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 329
Karry Zhuang 27.1 330 6 numbers:
Karry Zhuang 26.1 331
Karry Zhuang 27.1 332 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="112" width="444"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 333
Karry Zhuang 27.1 334 7 numbers:
Karry Zhuang 26.1 335
Karry Zhuang 27.1 336 (% aria-label="image-20240420094632-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-14.png||data-widget="image" height="111" width="454"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 337
Karry Zhuang 27.1 338 8 numbers:
Karry Zhuang 26.1 339
Karry Zhuang 164.2 340 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
Edwin Chen 82.1 341
Karry Zhuang 164.2 342 (% title="Click and drag to resize" %)​
Edwin Chen 82.1 343
Karry Zhuang 164.2 344 == 2.5 Pressure Pointer Meter Calibration ==
345
346 === 2.5.1 Introduce ===
347
Xiaoling 179.3 348
Karry Zhuang 164.2 349 The pressure pointer meter of the example is 1.6MPa range
350
Xiaoling 179.3 351
Karry Zhuang 164.2 352 === 2.5.2 Fix Sensor to a Power Meter​ ===
353
Xiaoling 179.3 354
Karry Zhuang 164.2 355 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the pressure pointer meter.
356
357 [[image:image-20240516163229-1.jpeg||height="595" width="446"]]
358
Xiaoling 179.3 359
Karry Zhuang 164.2 360 === 2.5.3 Calibration ===
361
Xiaoling 179.3 362
Karry Zhuang 164.2 363 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
364
Karry Zhuang 175.1 365 For example, Select the corresponding serial port number, here 14.
Karry Zhuang 164.2 366
367 (% class="box warningmessage" %)
368 (((
369 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
370 )))
371
372 [[image:image-20240516163338-2.png||height="455" width="733"]]
373
374
375 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
376
377 [[image:image-20240516163423-3.png]]
378
379
Xiaoling 179.3 380 Click **"enable Raw"** and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
Karry Zhuang 164.2 381
382 [[image:image-20240516163501-4.png||height="482" width="694"]]
383
384 [[image:image-20240516163528-5.png||height="336" width="696"]]
385
386
387 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the pressure pointer meter, as shown below.
388
389 The coordinates of the pressure pointer table are located as shown below.
390
391 1 is the start point, 2 is the center point, and 3 is the end point.
392
393 The (x,y) coordinate on the image is located at the bottom left corner.
394
395 [[image:image-20240516163622-6.png||height="648" width="666"]]
396
397
Karry Zhuang 166.2 398 Click on the ROI settingbutton in himax_amr_pc_tool. it will have three optionsThe long dial" option is a long dial dial.The "short dial" option is a short pointer and a number of wheel dial.The digit wheeler option is the digital wheel dial.Now the calibration is the pressure pointer table, which is long dialon."
Karry Zhuang 164.2 399
Karry Zhuang 166.2 400 [[image:image-20240516163910-7.png]]
Karry Zhuang 164.2 401
402
Karry Zhuang 166.2 403 Fill in the values of the coordinates you just got, and it's best to get one and write one
Karry Zhuang 164.2 404
Karry Zhuang 166.2 405 1 Coordinates of the starting point of the scale
406
407 2 Coordinates of the center point of the dial
408
409 3 Coordinates of the end of the scale
410
411 4 Starting scale value
412
413 5 End point scale value *100
414
Karry Zhuang 174.1 415 After filling in the data, click "send ROI" to save the Settings and click "Cancel" to exit.
Karry Zhuang 166.2 416
Karry Zhuang 174.1 417 [[image:image-20240516164128-13.png||height="410" width="889"]]
Karry Zhuang 166.2 418
419
Karry Zhuang 174.1 420 After the calibration process is completed, The AIS cannot move thereafter to avoid misreading.
Karry Zhuang 166.2 421
Karry Zhuang 174.1 422 it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
Karry Zhuang 166.2 423
Karry Zhuang 174.1 424 [[image:image-20240516164153-14.png]]
Karry Zhuang 166.2 425
426
Xiaoling 179.6 427 = (% title="Click and drag to resize" %)3. Get Sensor Data(%%) =
Edwin Chen 82.1 428
Karry Zhuang 151.2 429 == (% title="Click and drag to resize" %)3.1 Get Image and show in PC(%%) ==
Edwin Chen 82.1 430
Xiaoling 179.3 431
Karry Zhuang 150.1 432 To get the AIS current image on the PC, you can  connect AIS to your PC with TTL to send commands through the serial port to obtain relevant data packets.
Karry Zhuang 119.2 433
434
Xiaoling 179.2 435 === (% style="color:inherit; font-family:inherit; font-size:23px" %)3.1.1 The image date are obtained by serial port(%%) ===
436
Xiaoling 179.3 437
Karry Zhuang 150.1 438 Select the corresponding baud rate and serial port number through the serial port tool, select HEX display and HEX send, and continuously receive data from the AIS Sensor
Karry Zhuang 119.3 439
Karry Zhuang 155.1 440 [[image:image-20240514161623-2.png||height="541" width="1439"]]
Karry Zhuang 119.4 441
Karry Zhuang 150.1 442 In the serial port to send data C0 5A 00 00 00 00 04, and then send C0 5A 00 00 00 00 09, AIS Sensor will send a real-time image of the data packet, and then stop sending. Start with FFD8 and put it in TXT file
Karry Zhuang 119.4 443
Karry Zhuang 155.1 444 [[image:image-20240514161658-3.png||height="544" width="1441"]]
Karry Zhuang 119.4 445
446
Karry Zhuang 151.2 447 === 3.1.2 Combined image ===
Karry Zhuang 119.4 448
Xiaoling 179.3 449
Karry Zhuang 130.5 450 Once all the data has been uploaded to the TTN platform, the subsequent step involves concatenating each packet in sequential order and saving it into a new TXT file. It is important to note that the first 8 bytes of each packet should be removed before concatenation.
Karry Zhuang 130.2 451
Karry Zhuang 130.5 452 When you combine all the packets, you need to convert the data inside to binary. Here the conversion is demonstrated using the [[WinHex>>http://www.x-ways.net/winhex/index-m.html]] software.
Karry Zhuang 130.2 453
Karry Zhuang 136.2 454 Open WinHex to open the combined image data file.
Karry Zhuang 130.3 455
Karry Zhuang 136.2 456 [[image:1714467040612-103.png||height="134" width="649"]]
Karry Zhuang 130.4 457
458
Xiaoling 179.3 459 Click on the **edit** option to choose and **convert**.
460
Karry Zhuang 136.2 461 [[image:1714467065723-178.png||height="349" width="762"]]
462
463
Xiaoling 179.3 464 Choose the **Hex ASCII->Binary** option and then click OK.
465
Karry Zhuang 136.2 466 [[image:1714467089355-837.png||height="366" width="336"]]
467
468
Xiaoling 179.3 469 After the conversion is finished, click on **"File"** and choose **"Save As"**.
470
Karry Zhuang 136.2 471 [[image:1714467112365-676.png]]
472
473
Karry Zhuang 183.1 474 Save as **image.jpg file** and click OK to generate a JPG file.
Xiaoling 179.3 475
Karry Zhuang 136.2 476 [[image:1714467126476-110.png]]
477
Xiaoling 179.3 478
Karry Zhuang 136.2 479 Open the saved JPG file to display the image transmitted by the AIS Sensor through the serial port.
480
481 [[image:1714467134950-189.png]]