Changes for page AI Image Sensor Calibration
Last modified by Karry Zhuang on 2025/07/03 11:59
From version 146.1
edited by Karry Zhuang
on 2024/05/06 17:34
on 2024/05/06 17:34
Change comment:
There is no comment for this version
To version 147.1
edited by Karry Zhuang
on 2024/05/06 17:37
on 2024/05/06 17:37
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -509,11 +509,32 @@ 509 509 510 510 = 4. Configure AIS Sensor using AT commands = 511 511 512 -== 4.1 SystemManagementCommands ==512 +== 4.1 Configure Methods == 513 513 514 -=== 4.1.1 Change Uplink Interval === 515 515 515 +SN50v3-LB/LS supports below configure method: 516 516 517 +* AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 518 +* AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 519 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 520 + 521 +== 4.2 General Commands == 522 + 523 + 524 +These commands are to configure: 525 + 526 +* General system settings like: uplink interval. 527 +* LoRaWAN protocol & radio related command. 528 + 529 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 530 + 531 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 532 + 533 +== 4.3 System Management Commands == 534 + 535 +=== 4.3.1 Change Uplink Interval === 536 + 537 + 517 517 Feature: Change LoRaWAN End Node Transmit Interval. 518 518 519 519 ... ... @@ -546,7 +546,7 @@ 546 546 547 547 (% style="display:none" %) (%%) 548 548 549 -== 4. 1.2 Request the server to send an ACK ==570 +== 4.3.2 Request the server to send an ACK == 550 550 551 551 552 552 (% style="color:blue" %)**AT Command: AT+PNACKMD** ... ... @@ -568,7 +568,7 @@ 568 568 0x34 00 ~/~/Same As AT+PNACKMD=0 569 569 570 570 571 -=== 4. 1.3 Set Interrupt Mode ===592 +=== 4.3.3 Set Interrupt Mode === 572 572 573 573 574 574 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -605,9 +605,12 @@ 605 605 * Example 2: Downlink Payload: 06000003 **~-~-->** AT+INTMOD1=3 606 606 * Example 3: Downlink Payload: 06000102 **~-~-->** AT+INTMOD2=2 607 607 608 -== 2.13 Clock logging (Since firmware version v1.2.1) == 629 +(% class="wikigeneratedid" %) 630 +=== === 609 609 632 +=== 4.3.4 Clock logging (Since firmware version v1.2.1) === 610 610 634 + 611 611 Sometimes when we deploy lots of end nodes in field. We want all sensors sample data at the same time, and upload these data together for analyze. In such case, we can use clock loging feature. 612 612 613 613 We can use this command to set the start time of data recording and the time interval to meet the requirements of the specific collection time of data.