Last modified by Karry Zhuang on 2025/07/03 11:59

From version 146.1
edited by Karry Zhuang
on 2024/05/06 17:34
Change comment: There is no comment for this version
To version 147.1
edited by Karry Zhuang
on 2024/05/06 17:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -509,11 +509,32 @@
509 509  
510 510  = 4. Configure AIS Sensor using AT commands =
511 511  
512 -== 4.1 System Management Commands ==
512 +== 4.1 Configure Methods ==
513 513  
514 -=== 4.1.1 Change Uplink Interval ===
515 515  
515 +SN50v3-LB/LS supports below configure method:
516 516  
517 +* AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
518 +* AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
519 +* LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
520 +
521 +== 4.2 General Commands ==
522 +
523 +
524 +These commands are to configure:
525 +
526 +* General system settings like: uplink interval.
527 +* LoRaWAN protocol & radio related command.
528 +
529 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
530 +
531 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
532 +
533 +== 4.3 System Management Commands ==
534 +
535 +=== 4.3.1 Change Uplink Interval ===
536 +
537 +
517 517  Feature: Change LoRaWAN End Node Transmit Interval.
518 518  
519 519  
... ... @@ -546,7 +546,7 @@
546 546  
547 547  (% style="display:none" %) (%%)
548 548  
549 -== 4.1.2 Request the server to send an ACK ==
570 +== 4.3.2 Request the server to send an ACK ==
550 550  
551 551  
552 552  (% style="color:blue" %)**AT Command: AT+PNACKMD**
... ... @@ -568,7 +568,7 @@
568 568  0x34 00  ~/~/Same As AT+PNACKMD=0
569 569  
570 570  
571 -=== 4.1.3 Set Interrupt Mode ===
592 +=== 4.3.3 Set Interrupt Mode ===
572 572  
573 573  
574 574  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -605,9 +605,12 @@
605 605  * Example 2: Downlink Payload: 06000003  **~-~-->**  AT+INTMOD1=3
606 606  * Example 3: Downlink Payload: 06000102  **~-~-->**  AT+INTMOD2=2
607 607  
608 -== 2.13 Clock logging (Since firmware version v1.2.1) ==
629 +(% class="wikigeneratedid" %)
630 +=== ===
609 609  
632 +=== 4.3.4 Clock logging (Since firmware version v1.2.1) ===
610 610  
634 +
611 611  Sometimes when we deploy lots of end nodes in field. We want all sensors sample data at the same time, and upload these data together for analyze. In such case, we can use clock loging feature.
612 612  
613 613  We can use this command to set the start time of data recording and the time interval to meet the requirements of the specific collection time of data.