<
From version < 26.1 >
edited by Mengting Qiu
on 2023/11/24 14:26
To version < 30.1 >
edited by Mengting Qiu
on 2023/11/24 14:43
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,21 +4,17 @@
4 4  
5 5  
6 6  
7 += 1. Introduction =
7 7  
9 +This chapter describes how to switch LoRaWAN server by rejoin feature.
8 8  
9 9  
10 -= 1. introduction =
11 -
12 -This chapter describes switch LoRaWAN server by rejoin feature.
13 -
14 -
15 15  = 2. What is the rejoin feature? =
16 16  
17 -rejoin feature is that if the ACK packet sent by the platform to the node is not received within the set time range, the offline detection will be started.
14 +Rejoin feature is that if the ACK packet sent by the platform to the node is not received within the set time range, the offline detection will be started.
18 18  
19 -== 2.1offline rejoining (LWS007) ==
16 +== 2.1 Offline Rejoining (LWS007) ==
20 20  
21 -
22 22  (% style="color:blue" %)**AT Command: AT+DDETECT**
23 23  
24 24  AT+DDETECT=<Flag>,<ACK_Timout_1>,<ACK_Timout_2> (Default Value: AT+DDETECT=1,1440,2880)
... ... @@ -78,7 +78,6 @@
78 78  
79 79  Feature: Change LoRaWAN End Node Transmit Interval.
80 80  
81 -
82 82  (% style="color:blue" %)**AT Command: AT+TDC**
83 83  
84 84  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:727.222px" %)
... ... @@ -170,7 +170,7 @@
170 170  
171 171  * (% style="color:blue" %)**It is recommended to restore the factory reset directly:**
172 172  
173 -(% style="color:red" %)** downlink payload: 0x04FE**
168 +(% style="color:red" %)** Downlink payload: 0x04FE**
174 174  
175 175   [[image:image-20231124114451-10.png||height="377" width="826"]]
176 176  
... ... @@ -177,12 +177,22 @@
177 177  [[image:image-20231124115256-11.png||height="409" width="767"]]
178 178  
179 179  
175 +After the delivery is successful, the node is connected to the network again and factory Settings are restored.
176 +
177 +[[image:image-20231124141041-1.png||height="395" width="801"]]
178 +
179 +[[image:image-20231124141141-2.png||height="460" width="802"]]
180 +
181 +
180 180  * (% style="color:blue" %)**If the device has other configurations to keep, users can also choose to configure the default TDC and default offline detection time separately.**
181 181  
184 +[[image:image-20231124142829-4.png||height="451" width="626"]]
182 182  
183 183  
187 +[[image:image-20231124142645-3.png||height="452" width="622"]]
184 184  
185 185  
190 +(% style="color:red" %)**Note: To set these two commands separately, users must restore the default offline detection time before configuring the default TDC time.**
186 186  
187 187  
188 188  
... ... @@ -190,4 +190,5 @@
190 190  
191 191  
192 192  
198 +
193 193  
image-20231124142829-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +39.6 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0