Show last authors
1 {{box cssClass="floatinginfobox" title="**Contents**"}}
2 {{toc/}}
3 {{/box}}
4
5 = **1. Overview** =
6
7 (((
8 Shipped LT-22222-L is base on LoRaWAN protocol. We also develop a open source Point to Point LoRa protocol for LT-22222-L. The source code and hex file can be found at:
9 )))
10
11 (((
12 [[Point to Point Software for LT-22222-L>>https://github.com/dragino/LT-22222-L]].
13 )))
14
15 == ==
16
17 = **2. Features for this firmware** =
18
19
20 == **2.1  Point To Point** ==
21
22
23 [[image:image-20220602111219-1.png||height="472" width="972"]]
24
25
26 (% class="wikigeneratedid" id="H2.2.Configure" %)
27 (% style="color:blue" %)**Configure:**
28
29
30 (% border="1" style="background-color:#f7faff; color:black; width:500px" %)
31 |=**A's configuration**|=**B's configuration**
32 |AT+GROUPMOD=0|AT+GROUPMOD=0
33 |AT+TXCHS=868700000|AT+TXCHS=869000000
34 |AT+RXCHS=869000000|AT+RXCHS=868700000
35 |AT+TRIG1=2,50|AT+TRIG1=2,50
36 |AT+TRIG2=2,50|AT+TRIG2=2,50
37 |AT+DI1TODO1=2|AT+DI1TODO1=2
38 |AT+DI1TORO1=2|AT+DI1TORO1=2
39 |AT+DI2TODO2=2 |AT+DI2TODO2=2
40 |AT+DI2TORO2=2|AT+DI2TORO2=2
41
42 == **2.2  Point To Mult-Point ** ==
43
44
45 [[image:image-20220602111219-2.png]]
46
47
48 [[image:image-20220602111219-3.png]]
49
50 If the sender does not get the ACK reply from the receiver, it will retransmit up to 4 times, each interval is 6 seconds, and the UplinkCounter of the retransmission will not increase.
51
52
53 == **2.3 AT command** ==
54
55
56 ATZ :  Trig a reset of the MCU
57
58 AT+FDR : Reset Parameters to Factory Default, Keys Reserve
59
60 AT+FCU : Get or Set the Frame Counter Uplink
61
62 AT+FCD : Get or Set the Frame Counter Downlink
63
64 AT+TXP : Get or Set the transmit power, the maximum is 20dBm (default is 14dBm)
65
66 AT+SYNC : Get or Set the Sync word [1:0x34,0:0x12] (default is 1)
67
68 AT+PMB : Get or Set the preamble (default:8)
69
70 AT+TXCHS : Get or Set the transmit frequency of TX (default:868700000)
71
72 AT+TXSF : Get or Set the spreading factor of TX (7 to 12) (default:12)
73
74 AT+RXCHS : Get or Set the transmit frequency of RX (default:869000000)
75
76 AT+RXSF : Get or Set the spreading factor of RX (7 to 12) (default:12)
77
78 AT+BW : Get or Set the bandwidth [0:125khz,1:250khz,2:500khz] (default:0)
79
80 AT+CR : Get or Set the coding rate [1: 4/5, 2: 4/6, 3: 4/7, 4: 4/8] (default:1)
81
82 AT+TDC : Get or set the application data transmission interval in ms(default 10 minutes)
83
84 AT+VER : Get firmware version number
85
86 AT+SEND : Set Custom sent hex data
87
88 AT+GROUPMOD : Set or Get the grouping mode of the device (default: 0)
89
90 AT+GROUPID : Set or Get the password for matching between TX group and RX group, which can be composed of numbers or characters (default: 12345678)
91
92 AT+TRIG1 : Set or Get the DI1 pin interrupt trigger mode (default 0,0)
93
94 AT+TRIG2 : Set or Get the DI2 pin interrupt trigger mode (default 0,0)
95
96 AT+DI1TODO1 : Set or get the mode in which DI1 maps to DO1 (default 0)
97
98 AT+DI1TORO1 : Set or get the mode in which DI1 maps to RO1(default 0)
99
100 AT+DI2TODO2 : Set or get the mode in which DI2 maps to DO2(default 0)
101
102 AT+DI2TORO2 : Set or get the mode in which DI2 maps to RO2(default 0)
103
104
105
106 **Example1:** AT+SEND=01020304 will send a payload of 01020304
107
108
109 i.g. AT+TRIGx=a  Trigger directly without triggering time
110
111 AT+TRIGx=a,b  a=0, falling edge;
112
113 a=1, rising edge;
114
115 a=2, falling edge or rising edge.
116
117 b, triggering time in milliseconds
118
119 AT+TRIGx=2,50  Falling edge or rising edge trigger, and the trigger time exceeds 50ms
120
121
122 i.g. AT+DI1TODO1= maps value
123
124 AT+DI1TORO1= maps value
125
126 AT+DI2TODO2= maps value
127
128 AT+DI2TORO2= maps value
129
130
131
132
133 (% border="1" style="background-color:#f7faff; color:black; width:706px" %)
134 |=(% style="width: 102px;" %)Maps value|=(% style="width: 331px;" %)DIx to DOx|=(% style="width: 268px;" %)DIx to ROx
135 |(% style="width:102px" %)0|(% style="width:331px" %)No Action|(% style="width:268px" %)No Action
136 |(% style="width:102px" %)1|(% style="width:331px" %)If DIx is high, control DOx to output low level, If DIx is low, control DOx to output high level|(% style="width:268px" %)(((
137 If DIx is high, control ROx to close,
138
139 if DIx is low, control ROx to open
140 )))
141 |(% style="width:102px" %)2|(% style="width:331px" %)If DIx is high, control DOx to output high level, If DIx is low, control DOx to output low level|(% style="width:268px" %)(((
142 If DIx is high, control ROx to open,
143
144 if DIx is low, control ROx to close
145 )))
146 |(% style="width:102px" %)3|(% style="width:331px" %)DOx state flip|(% style="width:268px" %)ROx state flip
147
148 i.g. AT+GROUPMOD=0  Set to point to point mode
149
150 AT+GROUPMOD=0,aa  Set the TX group that controls the number of aa (The maximum value of aa is 8)
151
152 AT+GROUPMOD=1,bb   Set to the RX group controlled by the TX group, numbered bb(The maximum value of aa is 8)
153
154
155 AT+GROUPMOD=0,2  Set to control the TX group of the two RX groups
156
157 AT+GROUPMOD=1,1  Set the RX group numbered 1
158
159 AT+GROUPMOD=1,2  Set the RX group numbered 2
160
161
162
163 == **2.4 Data Format** ==
164
165 8 bytes of GROUPID + 9 bytes of payload + 4 bytes of checksum
166
167
168 **Payload:**
169
170 (% border="1" style="background-color:#f7faff; color:black; width:938px" %)
171 |=(% style="width: 123px;" %)**Size (bytes)**|=(% style="width: 107px;" %)1|=(% style="width: 107px;" %)1|=(% style="width: 107px;" %)1|=(% style="width: 107px;" %)1|=(% style="width: 107px;" %)1|=(% style="width: 107px;" %)1|=(% style="width: 107px;" %)1|=(% style="width: 107px;" %)1|=(% style="width: 107px;" %)1
172 |(% style="width:123px" %)**Value**|(% style="width:38px" %)address|(% style="width:70px" %)request|(% style="width:52px" %)ACK|(% style="width:127px" %)(((
173 DI1&
174
175 DI1 level
176 )))|(% style="width:101px" %)DI1TODO1|(% style="width:91px" %)DI1TORO1|(% style="width:111px" %)(((
177 DI2&
178
179 DI2 level
180 )))|(% style="width:105px" %)DI2TODO2|(% style="width:106px" %)DI2TORO2
181
182 (% style="color:#037691" %)**The first byte**(%%)**:**  00 is the broadcast address, 01-08 is the RX group number.
183
184 (% style="color:#037691" %)**The second byte**(%%)**:**  send mapping request when not 0, not request when it is 0.
185
186 (% style="color:#037691" %)**The third byte**(%%)**:**  ACK returned to the sender after the mapping is completed.
187
188 (% style="color:#037691" %)**The fourth byte**(%%)**:**  the high four bits are 1 to represent DI1, and the low four bits are the level of DI1 when the interrupt is triggered.
189
190 (% style="color:#037691" %)**The Fifth byte**(%%)**:  **DI1TODO1 when the interrupt is triggered, 0 when the interrupt is not triggered.
191
192 (% style="color:#037691" %)**The Sixth byte**(%%)**:**  0 does not trigger interrupt when DI1TORO1 interrupt is triggered.
193
194 (% style="color:#037691" %)**The seventh byte**(%%)**:**  the high four bits are 2 to represent DI2, and the low four bits are the level of DI2 when the interrupt is triggered.
195
196 (% style="color:#037691" %)**The 8th byte**(%%)**:  **DI2TODO2 when the interrupt is triggered, 0 when the interrupt is not triggered.
197
198 (% style="color:#037691" %)**The 9th byte**(%%)**:**  DI2TORO2 when an interrupt is triggered, 0 when an interrupt is not triggered.
199
200
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0