Last modified by Mengting Qiu on 2025/07/29 15:24

From version 49.3
edited by Mengting Qiu
on 2025/07/29 13:58
Change comment: There is no comment for this version
To version 45.1
edited by Mengting Qiu
on 2025/03/06 13:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Dragino -NB/-CB device connection to AWS platform instructions
1 +Dragino NB device connection to AWS platform instructions
Content
... ... @@ -322,18 +322,6 @@
322 322  After completing the certificate configuration, Burn the [[bootloader>>https://www.dropbox.com/sh/u0uzvvnn58yrie4/AAAvvF_KRveNgmDejzp23ziLa/NB-IoT/Bootloader?dl=0&subfolder_nav_tracking=1]] firmware first, then re-burn the original working [[firmware>>https://www.dropbox.com/sh/u0uzvvnn58yrie4/AACREHllkTe0rATD4ZOqddyga/NB-IoT?dl=0]].
323 323  
324 324  
325 -==== 4.1.2.5 Overwriting Certificates on -NB/-NS Models ====
326 -
327 -
328 -The -NB/-NS modules (BC660K) do not support clearing certificates via AT commands or firmware updates.
329 -
330 -To effectively "clear" existing certificates, users may overwrite them with arbitrary data by following these steps:
331 -
332 -1. Overwrite Certificates:
333 -
334 -
335 -
336 -
337 337  == 4.2  For -CB /-CS model ==
338 338  
339 339  === 4.2.1 Upgrade the firmware to configure TLS firmware to set the certificate ===
... ... @@ -349,6 +349,8 @@
349 349  
350 350  Methods to Update Firmware:
351 351  
340 +* (Recommended way) OTA firmware update via BLE: [[**Instruction**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE_Firmware_Update_NB_Sensors_BC660K-GL/]].
341 +
352 352  * Update through UART TTL interface : **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART_Access_for_NB_ST_BC660K-GL/#H4.2UpdateFirmware28Assumethedevicealreadyhaveabootloader29]]**.
353 353  
354 354  === 4.2.2 Configure certificate ===
... ... @@ -537,15 +537,9 @@
537 537  Display(% style="color:blue" %)** "Successfully configured client private key."**(%%) If the configuration is successful, otherwise it is considered configuration failure.
538 538  
539 539  
540 -==== 4.2.2.4 Re-upgrade the firmware ====
530 +==== 4.2.2.4 For -CB /-CS model Certificate setting error/change certificate ====
541 541  
542 542  
543 -After completing the certificate configuration, Burn the [[bootloader>>https://www.dropbox.com/scl/fo/ztlw35a9xbkomu71u31im/AE23WqlQ8CKU4cuy-sP1JkM/Utility/NB-IoT%20Bootloader?rlkey=ojjcsw927eaow01dgooldq3nu&e=1&subfolder_nav_tracking=1&dl=0]] firmware first, then re-burn the original working [[firmware>>https://www.dropbox.com/scl/fo/ztlw35a9xbkomu71u31im/ANd2flSqspRRXl-ksF6gUqk/LTE-M?dl=0&rlkey=ojjcsw927eaow01dgooldq3nu&subfolder_nav_tracking=1]].
544 -
545 -
546 -==== 4.2.2.5 For -CB /-CS model Certificate setting error/change certificate ====
547 -
548 -
549 549  (% data-sider-select-id="7c5a8abc-e707-467b-ac02-db0a89098320" %)When you set the wrong certificate or you need to re-set another certificate.
550 550  Please use the following three commands:
551 551