Skip to main content

WSS-09 -- 9 in 1 Weather Station Sensor

1. Overview and Spec

Older versions of interfaces                            New version of the interface

Older versions of interfaces New version of the interface

Power Input: 10 ~ 30VDC

Max Power Consumption: 1.2W

Wind Speed:

  • Range: 0~60m/s
  • Accuracy: ±(0.2m/s±0.02*v)(v : the wind speed)
  • Ultrasonic measurement,no start wind strength needed

Wind Direction:

  • Range: 0~3599
  • Accuracy: ±3°
  • Ultrasonic measurement, no start wind strength needed
  • Built-in electronic compass. No need to consider installation direction

Temperature:

  • Range: -40°C ~ +80°C
  • Accuracy: ±0.5°C

Humidity:

  • Range: 0 ~ 99% RH
  • Accuracy Tolerance : Typ ±3% RH

Air Pressure:

  • Accuracy: ±0.15kPa@25°C 101kPa
  • Range: 0~120kPa

Noise:

  • Range: 30dB~120dB
  • Accuracy: ±0.5dB

PM2.5:

  • Range: 0~1000ug/m3
  • Accuracy: ±3%FS
  • Resolution: 1ug/m3

PM10:

  • Range: 0~1000ug/m3
  • Accuracy: ±3%FS
  • Resolution: 1ug/m3

llumination:

  • Range: 0~200k Lux
  • Accuracy: ±7%(25 °C)

2. Wiring

2.1 Older version wiring

image

2.2 New version wiring

image

3. Mechinical Drawing

Device Dimension

image

Installation

  • Make sure the device is horizontal installed
  • Device include electronic compass. No need to consider installation direction to get correct wind direction.

4. RS485 Commands

The RS485 command is as follows: Weather_Sensors_Modbus_Command_List