Changes for page SE01-LB/LS -- LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Edwin Chen on 2024/02/07 10:40
Change comment:
Uploaded new attachment "image-20230606163540-1.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -53,6 +53,7 @@ 53 53 * 8500mAh Battery for long term use 54 54 55 55 56 + 56 56 == 1.3 Specification == 57 57 58 58 ... ... @@ -103,6 +103,7 @@ 103 103 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 104 104 105 105 107 + 106 106 == 1.4 Applications == 107 107 108 108 ... ... @@ -109,6 +109,7 @@ 109 109 * Smart Agriculture 110 110 111 111 114 + 112 112 == 1.5 Sleep mode and working mode == 113 113 114 114 ... ... @@ -137,6 +137,7 @@ 137 137 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 138 138 139 139 143 + 140 140 == 1.7 BLE connection == 141 141 142 142 ... ... @@ -259,6 +259,7 @@ 259 259 ))) 260 260 261 261 266 + 262 262 === 2.3.2 MOD~=1(Original value) === 263 263 264 264 ... ... @@ -274,6 +274,7 @@ 274 274 ))) 275 275 276 276 282 + 277 277 === 2.3.3 Battery Info === 278 278 279 279 ... ... @@ -481,72 +481,10 @@ 481 481 482 482 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 483 483 484 -=== 2.6.4 Datalog Uplink payload (FPORT~=3) === 485 485 486 - TheDataloguplinks willusebelowpayloadformat.491 +=== 2.6.4 Poll sensor value === 487 487 488 -**Retrieval data payload:** 489 489 490 -**MOD=0:** 491 - 492 -|=((( 493 -**Size(bytes)** 494 -)))|=**2**|=**2**|=**2**|=**1**|=**4** 495 -|Value|Humidity|((( 496 -Temperature 497 - 498 - 499 -)))|Soil Conductivity (EC)|((( 500 -MOD& Level of PA8 501 -)))|Unix Time Stamp 502 - 503 -**MOD=0:** 504 - 505 - 506 -|=((( 507 -**Size(bytes)** 508 -)))|=**2**|=**2**|=**2**|=**1**|=**4** 509 -|Value|soil dielectric constant|((( 510 -raw water soil 511 - 512 - 513 -)))|raw conduct soil|((( 514 -MOD& Level of PA8 515 -)))|Unix Time Stamp 516 - 517 -**Poll Message Flag**: 1: This message is a poll message reply. 518 - 519 -* Poll Message Flag is set to 1. 520 - 521 -* Each data entry is 11 bytes, to save airtime and battery, devices will send max bytes according to the current DR and Frequency bands. 522 - 523 -For example, in US915 band, the max payload for different DR is: 524 - 525 -**a) DR0:** max is 11 bytes so one entry of data 526 - 527 -**b) DR1:** max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 528 - 529 -**c) DR2:** total payload includes 11 entries of data 530 - 531 -**d) DR3: **total payload includes 22 entries of data. 532 - 533 -If devise doesn't have any data in the polling time. Device will uplink 11 bytes of 0 534 - 535 -**Example:** 536 - 537 -If SE01-LB has below data inside Flash: 538 - 539 -[[image:image-20230606163540-1.png]] 540 - 541 -If user sends below downlink command: 31646D84E1646D856C05 542 - 543 -Where : Start time: 646D84E1 = time 23/5/24 03:30:41 544 - 545 - Stop time: 646D856C= time 23/5/24 03:33:00 546 - 547 -=== 2.6.5 Poll sensor value === 548 - 549 - 550 550 Users can poll sensor values based on timestamps. Below is the downlink command. 551 551 552 552 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:425.818px" %) ... ... @@ -619,6 +619,7 @@ 619 619 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 620 620 621 621 566 + 622 622 == 3.2 General Commands == 623 623 624 624 ... ... @@ -736,6 +736,7 @@ 736 736 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 737 737 738 738 684 + 739 739 === 3.3.4 Set Power Output Duration === 740 740 741 741 ... ... @@ -766,6 +766,7 @@ 766 766 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 767 767 768 768 715 + 769 769 = 4. Battery & Power Consumption = 770 770 771 771 ... ... @@ -795,6 +795,7 @@ 795 795 * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 796 796 797 797 745 + 798 798 = 6. FAQ = 799 799 800 800 == 6.1 AT Commands input doesn't work == ... ... @@ -841,6 +841,7 @@ 841 841 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 842 842 843 843 792 + 844 844 = 8. Packing Info = 845 845 846 846 ... ... @@ -859,6 +859,7 @@ 859 859 * Weight / pcs : g 860 860 861 861 811 + 862 862 = 9. Support = 863 863 864 864