... ... @@ -429,21 +429,14 @@
429 429  Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0
430 430  
431 431  
432 -== 2.4 Payload Decoder file ==
433 433  
433 +== 2.6 Datalog Feature ==
434 434  
435 -In TTN, use can add a custom payload so it shows friendly reading
436 436  
437 -In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
438 -
439 -
440 -== 2.5 Datalog Feature ==
441 -
442 -
443 443  Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, CPL03-LB will store the reading for future retrieving purposes.
444 444  
445 445  
446 -=== 2.5.1 Ways to get datalog via LoRaWAN ===
439 +=== 2.6.1 Ways to get datalog via LoRaWAN ===
447 447  
448 448  
449 449  Set PNACKMD=1, CPL03-LB will wait for ACK for every uplink, when there is no LoRaWAN network,CPL03-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
... ... @@ -460,7 +460,7 @@
460 460  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]]
461 461  
462 462  
463 -=== 2.5.2 Unix TimeStamp ===
456 +=== 2.6.2 Unix TimeStamp ===
464 464  
465 465  
466 466  CPL03-LB uses Unix TimeStamp format based on
... ... @@ -477,7 +477,7 @@
477 477  So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
478 478  
479 479  
480 -=== 2.5.3 Set Device Time ===
473 +=== 2.6.3 Set Device Time ===
481 481  
482 482  
483 483  User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command.
... ... @@ -487,7 +487,7 @@
487 487  (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
488 488  
489 489  
490 -=== 2.5.4 Poll sensor value ===
483 +=== 2.6.4 Poll sensor value ===
491 491  
492 492  
493 493  Users can poll sensor values based on timestamps. Below is the downlink command.
... ... @@ -514,7 +514,7 @@
514 514  )))
515 515  
516 516  
517 -== 2.6 Frequency Plans ==
510 +== 2.7 Frequency Plans ==
518 518  
519 519  
520 520  The CPL03-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
... ... @@ -522,8 +522,34 @@
522 522  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
523 523  
524 524  
525 -= 3. Configure CPL03-LB =
518 +== 2.8 Installation in Soil ==
526 526  
520 +
521 +(% style="color:blue" %)**Measurement the soil surface**
522 +
523 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSE01-LoRaWAN%20Soil%20Moisture%20%26%20EC%20Sensor%20User%20Manual/WebHome/1654506634463-199.png?rev=1.1||alt="1654506634463-199.png"]] ​
524 +
525 +(((
526 +(((
527 +Choose the proper measuring position. Avoid the probe to touch rocks or hard things. Split the surface soil according to the measured deep. Keep the measured as original density. Vertical insert the probe into the soil to be measured. Make sure not shake when inserting.
528 +)))
529 +)))
530 +
531 +
532 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSE01-LoRaWAN%20Soil%20Moisture%20%26%20EC%20Sensor%20User%20Manual/WebHome/1654506665940-119.png?rev=1.1||alt="1654506665940-119.png"]]
533 +
534 +(((
535 +Dig a hole with diameter > 20CM.
536 +)))
537 +
538 +(((
539 +Horizontal insert the probe to the soil and fill the hole for long term measurement.
540 +
541 +
542 +)))
543 +
544 += 3. Configure SE01-LB =
545 +
527 527  == 3.1 Configure Methods ==
528 528  
529 529  
... ... @@ -549,10 +549,10 @@
549 549  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
550 550  
551 551  
552 -== 3.3 Commands special design for CPL03-LB ==
571 +== 3.3 Commands special design for SE01-LB ==
553 553  
554 554  
555 -These commands only valid for CPL03-LB, as below:
574 +These commands only valid for SE01-LB, as below:
556 556  
557 557  
558 558  === 3.3.1 Set Transmit Interval Time ===
... ... @@ -617,204 +617,9 @@
617 617  No downlink command for this feature.
618 618  
619 619  
620 -=== 3.3.3 Get Device Status ===
639 +=== 3.3.3 Set Interrupt Mode ===
621 621  
622 622  
623 -Send a LoRaWAN downlink to ask device send Alarm settings.
624 -
625 -(% style="color:blue" %)**Downlink Payload:  **(%%)0x26 01
626 -
627 -Sensor will upload Device Status via FPORT=5. See payload section for detail.
628 -
629 -
630 -=== 3.3.4 Enable / Disable Alarm ===
631 -
632 -
633 -Feature: Enable/Disable Alarm for open/close event. Default value 0.
634 -
635 -(% style="color:blue" %)**AT Command:**
636 -
637 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
638 -|(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:278px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Response**
639 -|(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK
640 -|(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK
641 -
642 -(% style="color:blue" %)**Downlink Command:**
643 -
644 -**0xA7 01**  ~/~/  Same As AT+DISALARM=1
645 -
646 -**0xA7 00    ** ~/~/  Same As AT+DISALARM=0
647 -
648 -
649 -=== 3.3.5 Alarm Base on Timeout ===
650 -
651 -
652 -(((
653 -CPL03-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
654 -)))
655 -
656 -
657 -(((
658 -(% style="color:#4f81bd" %)**1. Keep Status: Status to be monitor**
659 -)))
660 -
661 -(((
662 -**Keep Status = 1**: Monitor Close to Open event
663 -)))
664 -
665 -(((
666 -**Keep Status = 0**: Monitor Open to Close event
667 -)))
668 -
669 -
670 -(((
671 -(% style="color:#4f81bd" %)**2. Keep Time: Timeout to send an Alarm**
672 -)))
673 -
674 -(((
675 -Range 0 ~~ 65535(0xFFFF) seconds.
676 -)))
677 -
678 -(((
679 -If** keep time = 0**, Disable Alarm Base on Timeout feature.
680 -)))
681 -
682 -(((
683 -If **keep time > 0**, device will monitor the keep status event and send an alarm when status doesn’t change after timeout.
684 -)))
685 -
686 -
687 -(((
688 -(% style="color:#4f81bd" %)**AT Command**(%%) to configure:
689 -)))
690 -
691 -(((
692 -(% style="color:blue" %)**AT+TTRIG=1,30**(%%)  ~-~-> When the **Keep Status** change from connect to disconnect, and device remains in disconnect status for more than 30 seconds. CPL03-LB will send an uplink packet, the [[Alarm bit>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.
693 -)))
694 -
695 -(((
696 -(% style="color:blue" %)**AT+TTIG=0,0 **(%%) ~-~-> Default Value, disable timeout Alarm.
697 -)))
698 -
699 -
700 -(((
701 -(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure:
702 -)))
703 -
704 -(((
705 -**Command: 0xA9 aa bb cc**
706 -)))
707 -
708 -(((
709 -**A9: **Command Type Code
710 -)))
711 -
712 -(((
713 -**aa: **status to be monitored
714 -)))
715 -
716 -(((
717 -**bb cc: **timeout.
718 -)))
719 -
720 -
721 -(((
722 -If user send 0xA9 01 00 1E: equal to AT+TTRIG=1,30
723 -)))
724 -
725 -(((
726 -Or
727 -)))
728 -
729 -(((
730 -0xA9 00 00 00: Equal to AT+TTRIG=0,0. Disable timeout Alarm.
731 -)))
732 -
733 -
734 -=== 3.3.6 Clear Flash Record ===
735 -
736 -
737 -Feature: Clear flash storage for data log feature.
738 -
739 -(% style="color:blue" %)**AT Command: AT+CLRDTA**
740 -
741 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
742 -|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response**
743 -|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK
744 -
745 -(((
746 -(% style="color:blue" %)**Downlink Command:**
747 -)))
748 -
749 -(((
750 -* **Example**: 0xA301  ~/~/  Same as AT+CLRDTA
751 -)))
752 -
753 -
754 -
755 -=== 3.3.7 Set trigger mode ===
756 -
757 -
758 -Feature: Set the trigger interrupt mode.
759 -
760 -(% style="color:blue" %)**AT Command: AT+TTRMOD**
761 -
762 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:495px" %)
763 -|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 246px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 92px;background-color:#D9E2F3;color:#0070C0" %)**Response**
764 -|(% style="width:157px" %)(((
765 -AT+TTRMOD=1
766 -)))|(% style="width:156px" %)Count and trigger from open to close (rising edge)|(% style="width:89px" %)(((
767 -(((
768 -OK
769 -)))
770 -)))
771 -|(% style="width:157px" %)(((
772 -AT+TTRMOD=0
773 -)))|(% style="width:156px" %)Count and trigger from close to open (falling edge)|(% style="width:89px" %)(((
774 -OK
775 -)))
776 -
777 -(% style="color:blue" %)**Downlink Command:**
778 -
779 -* **Example**: 0xA401  ~/~/  Same as AT+ TTRMOD =1
780 -
781 -=== 3.3.8 Set the calculate flag ===
782 -
783 -
784 -Feature: Set the calculate flag
785 -
786 -(% style="color:blue" %)**AT Command: AT+CALCFLAG**
787 -
788 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %)
789 -|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response**
790 -|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK
791 -|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK
792 -
793 -(% style="color:blue" %)**Downlink Command:**
794 -
795 -* **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
796 -
797 -=== 3.3.9 Set count number ===
798 -
799 -
800 -Feature: Manually set the count number
801 -
802 -(% style="color:blue" %)**AT Command: AT+SETCNT**
803 -
804 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %)
805 -|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response**
806 -|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK
807 -|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK
808 -
809 -(% style="color:blue" %)**Downlink Command:**
810 -
811 -* **Example**: 0xA6000001  ~/~/  Same as AT+ SETCNT =1
812 -
813 -* **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
814 -
815 -=== 3.3.10 Set Interrupt Mode ===
816 -
817 -
818 818  Feature, Set Interrupt mode for PA8 of pin.
819 819  
820 820  When AT+INTMOD=0 is set, PA8 is used as a digital input port.
... ... @@ -846,7 +846,7 @@
846 846  
847 847  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
848 848  
849 -=== 3.3.11 Set Power Output Duration ===
673 +=== 3.3.4 Set Power Output Duration ===
850 850  
851 851  
852 852  Control the output duration 5V . Before each sampling, device will
... ... @@ -911,10 +911,24 @@
911 911  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
912 912  
913 913  
738 +== 6.2 ​Can I calibrate LSE01 to different soil types? ==
739 +
740 +
741 +(((
742 +LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]].
743 +)))
744 +
745 +
746 +== 6.3 ​Why I can't join TTN in US915 / AU915 bands? ==
747 +
748 +
749 +It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details.
750 +
751 +
914 914  = 7. Order Info =
915 915  
916 916  
917 -Part Number: (% style="color:blue" %)**CPL03-LB-XXX**
755 +Part Number: (% style="color:blue" %)**SE01-LB-XXX**
918 918  
919 919  (% style="color:red" %)**XXX**(%%): The default frequency band
920 920  
... ... @@ -934,12 +934,15 @@
934 934  
935 935  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
936 936  
775 +
776 +
777 +
937 937  = 8. ​Packing Info =
938 938  
939 939  
940 940  (% style="color:#037691" %)**Package Includes**:
941 941  
942 -* CPL03-LB LoRaWAN Pulse/Contact Sensor
783 +* SE01-LB LoRaWAN Soil Moisture & EC Sensor
943 943  
944 944  (% style="color:#037691" %)**Dimension and weight**:
945 945  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved