Changes for page SE01-LB/LS -- LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Edwin Chen on 2024/02/07 10:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -241,7 +241,7 @@ 241 241 ))) 242 242 243 243 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 244 -|**Size(bytes)**|**2**|**2**|**2**|**2**|**2**|**1** 244 +|(% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1** 245 245 |**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 246 246 Temperature 247 247 (Reserve, Ignore now) ... ... @@ -255,7 +255,7 @@ 255 255 This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation). 256 256 257 257 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 258 -|**Size(bytes)**|**2**|**2**|**2**|**2**|**2**|**1** 258 +|(% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1** 259 259 |**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 260 260 Temperature 261 261 (Reserve, Ignore now) ... ... @@ -290,12 +290,9 @@ 290 290 For example, if the data you get from the register is __0x05 0xDC__, the moisture content in the soil is 291 291 ))) 292 292 293 -((( 294 - 295 -))) 296 296 297 297 ((( 298 -(% style="color: #4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.**295 +(% style="color:blue" %)**05DC(H) = 1500(D) /100 = 15%.** 299 299 ))) 300 300 301 301 ... ... @@ -323,7 +323,7 @@ 323 323 324 324 325 325 ((( 326 -Obtain (% style="color: #4f81bd" %)**__soluble salt concentration__**(%%) in soil or (% style="color:#4f81bd" %)**__soluble ion concentration in liquid fertilizer__**(%%) or (% style="color:#4f81bd" %)**__planting medium__**(%%). The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000).323 +Obtain (% style="color:blue" %)**__soluble salt concentration__**(%%) in soil or (% style="color:blue" %)**__soluble ion concentration in liquid fertilizer__**(%%) or (% style="color:blue" %)**__planting medium__**(%%). The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000). 327 327 ))) 328 328 329 329 (((