From version < 67.13 >
edited by Xiaoling
on 2023/05/31 10:30
To version < 67.15 >
edited by Xiaoling
on 2023/05/31 10:57
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -241,7 +241,7 @@
241 241  )))
242 242  
243 243  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
244 -|**Size(bytes)**|**2**|**2**|**2**|**2**|**2**|**1**
244 +|(% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**
245 245  |**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
246 246  Temperature
247 247  (Reserve, Ignore now)
... ... @@ -255,7 +255,7 @@
255 255  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
256 256  
257 257  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
258 -|**Size(bytes)**|**2**|**2**|**2**|**2**|**2**|**1**
258 +|(% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**
259 259  |**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
260 260  Temperature
261 261  (Reserve, Ignore now)
... ... @@ -290,12 +290,9 @@
290 290  For example, if the data you get from the register is __0x05 0xDC__, the moisture content in the soil is
291 291  )))
292 292  
293 -(((
294 -
295 -)))
296 296  
297 297  (((
298 -(% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.**
295 +(% style="color:blue" %)**05DC(H) = 1500(D) /100 = 15%.**
299 299  )))
300 300  
301 301  
... ... @@ -323,7 +323,7 @@
323 323  
324 324  
325 325  (((
326 -Obtain (% style="color:#4f81bd" %)**__soluble salt concentration__**(%%) in soil or (% style="color:#4f81bd" %)**__soluble ion concentration in liquid fertilizer__**(%%) or (% style="color:#4f81bd" %)**__planting medium__**(%%). The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000).
323 +Obtain (% style="color:blue" %)**__soluble salt concentration__**(%%) in soil or (% style="color:blue" %)**__soluble ion concentration in liquid fertilizer__**(%%) or (% style="color:blue" %)**__planting medium__**(%%). The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000).
327 327  )))
328 328  
329 329  (((
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0