Changes for page SE01-LB/LS -- LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Edwin Chen on 2024/02/07 10:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -636,9 +636,204 @@ 636 636 No downlink command for this feature. 637 637 638 638 639 -=== 3.3.3 SetInterrupt Mode ===639 +=== 3.3.3 Get Device Status === 640 640 641 641 642 +Send a LoRaWAN downlink to ask device send Alarm settings. 643 + 644 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 645 + 646 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 647 + 648 + 649 +=== 3.3.4 Enable / Disable Alarm === 650 + 651 + 652 +Feature: Enable/Disable Alarm for open/close event. Default value 0. 653 + 654 +(% style="color:blue" %)**AT Command:** 655 + 656 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 657 +|(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:278px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Response** 658 +|(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK 659 +|(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK 660 + 661 +(% style="color:blue" %)**Downlink Command:** 662 + 663 +**0xA7 01** ~/~/ Same As AT+DISALARM=1 664 + 665 +**0xA7 00 ** ~/~/ Same As AT+DISALARM=0 666 + 667 + 668 +=== 3.3.5 Alarm Base on Timeout === 669 + 670 + 671 +((( 672 +CPL03-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: 673 +))) 674 + 675 + 676 +((( 677 +(% style="color:#4f81bd" %)**1. Keep Status: Status to be monitor** 678 +))) 679 + 680 +((( 681 +**Keep Status = 1**: Monitor Close to Open event 682 +))) 683 + 684 +((( 685 +**Keep Status = 0**: Monitor Open to Close event 686 +))) 687 + 688 + 689 +((( 690 +(% style="color:#4f81bd" %)**2. Keep Time: Timeout to send an Alarm** 691 +))) 692 + 693 +((( 694 +Range 0 ~~ 65535(0xFFFF) seconds. 695 +))) 696 + 697 +((( 698 +If** keep time = 0**, Disable Alarm Base on Timeout feature. 699 +))) 700 + 701 +((( 702 +If **keep time > 0**, device will monitor the keep status event and send an alarm when status doesn’t change after timeout. 703 +))) 704 + 705 + 706 +((( 707 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 708 +))) 709 + 710 +((( 711 +(% style="color:blue" %)**AT+TTRIG=1,30**(%%) ~-~-> When the **Keep Status** change from connect to disconnect, and device remains in disconnect status for more than 30 seconds. CPL03-LB will send an uplink packet, the [[Alarm bit>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1. 712 +))) 713 + 714 +((( 715 +(% style="color:blue" %)**AT+TTIG=0,0 **(%%) ~-~-> Default Value, disable timeout Alarm. 716 +))) 717 + 718 + 719 +((( 720 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 721 +))) 722 + 723 +((( 724 +**Command: 0xA9 aa bb cc** 725 +))) 726 + 727 +((( 728 +**A9: **Command Type Code 729 +))) 730 + 731 +((( 732 +**aa: **status to be monitored 733 +))) 734 + 735 +((( 736 +**bb cc: **timeout. 737 +))) 738 + 739 + 740 +((( 741 +If user send 0xA9 01 00 1E: equal to AT+TTRIG=1,30 742 +))) 743 + 744 +((( 745 +Or 746 +))) 747 + 748 +((( 749 +0xA9 00 00 00: Equal to AT+TTRIG=0,0. Disable timeout Alarm. 750 +))) 751 + 752 + 753 +=== 3.3.6 Clear Flash Record === 754 + 755 + 756 +Feature: Clear flash storage for data log feature. 757 + 758 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 759 + 760 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 761 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 762 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 763 + 764 +((( 765 +(% style="color:blue" %)**Downlink Command:** 766 +))) 767 + 768 +((( 769 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 770 +))) 771 + 772 + 773 + 774 +=== 3.3.7 Set trigger mode === 775 + 776 + 777 +Feature: Set the trigger interrupt mode. 778 + 779 +(% style="color:blue" %)**AT Command: AT+TTRMOD** 780 + 781 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:495px" %) 782 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 246px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 92px;background-color:#D9E2F3;color:#0070C0" %)**Response** 783 +|(% style="width:157px" %)((( 784 +AT+TTRMOD=1 785 +)))|(% style="width:156px" %)Count and trigger from open to close (rising edge)|(% style="width:89px" %)((( 786 +((( 787 +OK 788 +))) 789 +))) 790 +|(% style="width:157px" %)((( 791 +AT+TTRMOD=0 792 +)))|(% style="width:156px" %)Count and trigger from close to open (falling edge)|(% style="width:89px" %)((( 793 +OK 794 +))) 795 + 796 +(% style="color:blue" %)**Downlink Command:** 797 + 798 +* **Example**: 0xA401 ~/~/ Same as AT+ TTRMOD =1 799 + 800 +=== 3.3.8 Set the calculate flag === 801 + 802 + 803 +Feature: Set the calculate flag 804 + 805 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 806 + 807 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 808 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 809 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 810 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 811 + 812 +(% style="color:blue" %)**Downlink Command:** 813 + 814 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 815 + 816 +=== 3.3.9 Set count number === 817 + 818 + 819 +Feature: Manually set the count number 820 + 821 +(% style="color:blue" %)**AT Command: AT+SETCNT** 822 + 823 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 824 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 825 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 826 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 827 + 828 +(% style="color:blue" %)**Downlink Command:** 829 + 830 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 831 + 832 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 833 + 834 +=== 3.3.10 Set Interrupt Mode === 835 + 836 + 642 642 Feature, Set Interrupt mode for PA8 of pin. 643 643 644 644 When AT+INTMOD=0 is set, PA8 is used as a digital input port. ... ... @@ -670,7 +670,7 @@ 670 670 671 671 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 672 672 673 -=== 3.3. 4Set Power Output Duration ===868 +=== 3.3.11 Set Power Output Duration === 674 674 675 675 676 676 Control the output duration 5V . Before each sampling, device will ... ... @@ -735,24 +735,10 @@ 735 735 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 736 736 737 737 738 -== 6.2 Can I calibrate LSE01 to different soil types? == 739 - 740 - 741 -((( 742 -LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]]. 743 -))) 744 - 745 - 746 -== 6.3 Why I can't join TTN in US915 / AU915 bands? == 747 - 748 - 749 -It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details. 750 - 751 - 752 752 = 7. Order Info = 753 753 754 754 755 -Part Number: (% style="color:blue" %)** SE01-LB-XXX**936 +Part Number: (% style="color:blue" %)**CPL03-LB-XXX** 756 756 757 757 (% style="color:red" %)**XXX**(%%): The default frequency band 758 758 ... ... @@ -772,15 +772,12 @@ 772 772 773 773 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 774 774 775 - 776 - 777 - 778 778 = 8. Packing Info = 779 779 780 780 781 781 (% style="color:#037691" %)**Package Includes**: 782 782 783 -* SE01-LB LoRaWANSoilMoisture& EC Sensor961 +* CPL03-LB LoRaWAN Pulse/Contact Sensor 784 784 785 785 (% style="color:#037691" %)**Dimension and weight**: 786 786