Changes for page SE01-LB/LS -- LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Edwin Chen on 2024/02/07 10:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1024,7 +1024,7 @@ 1024 1024 1025 1025 Feature: Set the trigger interrupt mode. 1026 1026 1027 -(% style="color:b lue" %)**AT Command: AT+TTRMOD**1027 +(% style="color:#4f81bd" %)**AT Command: AT+TTRMOD** 1028 1028 1029 1029 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:495px" %) 1030 1030 |=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 246px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 92px;background-color:#D9E2F3;color:#0070C0" %)**Response** ... ... @@ -1041,7 +1041,7 @@ 1041 1041 OK 1042 1042 ))) 1043 1043 1044 -(% style="color:b lue" %)**Downlink Command:**1044 +(% style="color:#4f81bd" %)**Downlink Command:** 1045 1045 1046 1046 * **Example**: 0xA401 ~/~/ Same as AT+ TTRMOD =1 1047 1047 ... ... @@ -1055,7 +1055,7 @@ 1055 1055 1056 1056 Feature: Set the calculate flag 1057 1057 1058 -(% style="color:b lue" %)**AT Command: AT+CALCFLAG**1058 +(% style="color:#4f81bd" %)**AT Command: AT+CALCFLAG** 1059 1059 1060 1060 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 1061 1061 |=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** ... ... @@ -1062,7 +1062,7 @@ 1062 1062 |(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 1063 1063 |(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 1064 1064 1065 -(% style="color:b lue" %)**Downlink Command:**1065 +(% style="color:#4f81bd" %)**Downlink Command:** 1066 1066 1067 1067 * **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 1068 1068 ... ... @@ -1074,7 +1074,7 @@ 1074 1074 1075 1075 Feature: Manually set the count number 1076 1076 1077 -(% style="color:b lue" %)**AT Command: AT+SETCNT**1077 +(% style="color:#4f81bd" %)**AT Command: AT+SETCNT** 1078 1078 1079 1079 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 1080 1080 |=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** ... ... @@ -1081,10 +1081,9 @@ 1081 1081 |(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 1082 1082 |(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 1083 1083 1084 -(% style="color:b lue" %)**Downlink Command:**1084 +(% style="color:#4f81bd" %)**Downlink Command:** 1085 1085 1086 1086 * **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 1087 - 1088 1088 * **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 1089 1089 1090 1090 ... ... @@ -1121,7 +1121,6 @@ 1121 1121 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 1122 1122 1123 1123 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1124 - 1125 1125 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1126 1126 1127 1127