From version < 44.1 >
edited by Saxer Lin
on 2023/05/23 17:52
To version < 42.1 >
edited by Saxer Lin
on 2023/05/23 17:42
>
Change comment: Uploaded new attachment "image-20230523174230-1.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -132,20 +132,12 @@
132 132  If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
133 133  
134 134  
135 -== 1.7 Pin Definitions ==
135 +== 1.7  Hardware Variant ==
136 136  
137 -[[image:image-20230523174230-1.png]]
138 138  
139 -== ==
140 -
141 -== 1.8  Hardware Variant ==
142 -
143 -
144 144  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
145 145  |=(% style="width: 102px;background-color:#D9E2F3;color:#0070C0" %)Model|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)Photo|=(% style="width: 218px;background-color:#D9E2F3;color:#0070C0" %)Probe Info
146 -|(% style="width:102px" %)(((
147 -S31-LB
148 -)))|(% style="width:190px" %)[[image:S31.jpg]]|(% style="width:297px" %)(((
140 +|(% style="width:102px" %)S31-LB|(% style="width:190px" %)[[image:S31.jpg]]|(% style="width:297px" %)(((
149 149  1 x SHT31 Probe
150 150  
151 151  Cable Length : 2 meters
... ... @@ -152,9 +152,7 @@
152 152  
153 153  
154 154  )))
155 -|(% style="width:102px" %)(((
156 -S31B-LB
157 -)))|(% style="width:190px" %)[[image:S31B.jpg]]|(% style="width:297px" %)(((
147 +|(% style="width:102px" %)S31B-LB|(% style="width:190px" %)[[image:S31B.jpg]]|(% style="width:297px" %)(((
158 158  1 x SHT31 Probe
159 159  
160 160  Installed in device.
... ... @@ -164,7 +164,7 @@
164 164  
165 165  
166 166  
167 -== 1.9 Mechanical ==
157 +== 1.8 Mechanical ==
168 168  
169 169  
170 170  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]]
... ... @@ -327,7 +327,7 @@
327 327  [[Humidity>>||anchor="HHumidity"]]
328 328  )))
329 329  
330 -==== (% style="color:#4472c4" %)**2.3.2.1 Battery**(%%) ====
320 +==== (% style="color:#4472c4" %)**Battery**(%%) ====
331 331  
332 332  Sensor Battery Level.
333 333  
... ... @@ -337,7 +337,7 @@
337 337  
338 338  
339 339  
340 -==== (% style="color:#4472c4" %)**2.3.2.2 Temperature**(%%) ====
330 +==== (% style="color:#4472c4" %)**Temperature**(%%) ====
341 341  
342 342  **Example**:
343 343  
... ... @@ -348,13 +348,13 @@
348 348  (FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative)
349 349  
350 350  
351 -==== (% style="color:#4472c4" %)**2.3.2.3 Humidity**(%%) ====
341 +==== (% style="color:#4472c4" %)**Humidity**(%%) ====
352 352  
353 353  
354 354  Read:0x(0197)=412    Value:  412 / 10=41.2, So 41.2%
355 355  
356 356  
357 -==== (% style="color:#4472c4" %)**2.3.2.4 Alarm Flag& MOD**(%%) ====
347 +==== (% style="color:#4472c4" %)**Alarm Flag& MOD**(%%) ====
358 358  
359 359  
360 360  **Example:**
... ... @@ -389,12 +389,8 @@
389 389  
390 390  Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
391 391  
392 -* (((
393 -a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server.
394 -)))
395 -* (((
396 -b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages.
397 -)))
382 +* a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server.
383 +* b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages.
398 398  
399 399  Below is the typical case for the auto-update datalog feature (Set PNACKMD=1)
400 400  
... ... @@ -682,7 +682,7 @@
682 682  === 3.3.7 Set Interrupt Mode ===
683 683  
684 684  
685 -Feature, Set Interrupt mode for PA8 of pin.
671 +Feature, Set Interrupt mode for PA8 of PIN.
686 686  
687 687  (% style="color:blue" %)**AT Command: AT+INTMOD**
688 688  
... ... @@ -740,6 +740,7 @@
740 740  * Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
741 741  * Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
742 742  
729 +(% class="wikigeneratedid" %)
743 743  = =
744 744  
745 745  = 4. Battery & Power Consumption =
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0