From version < 81.2 >
edited by Xiaoling
on 2022/12/07 18:05
To version < 81.4 >
edited by Xiaoling
on 2022/12/07 18:13
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -51,7 +51,6 @@
51 51  * Micro SIM card slot for NB-IoT SIM
52 52  * 8500mAh Battery for long-term use
53 53  
54 -
55 55  == 1.3 Radar probe specification ==
56 56  
57 57  
... ... @@ -65,7 +65,6 @@
65 65  * Vertical Angel: 23°
66 66  
67 67  
68 -
69 69  == 1.4  Storage Temperature ==
70 70  
71 71  
... ... @@ -89,7 +89,6 @@
89 89  * Sewer
90 90  * Bottom water level monitoring
91 91  
92 -
93 93  == 1.6  Specification ==
94 94  
95 95  
... ... @@ -107,7 +107,6 @@
107 107  * B20 @H-FDD: 800MHz
108 108  * B28 @H-FDD: 700MHz
109 109  
110 -
111 111  == 1.7  Installation ==
112 112  
113 113  
... ... @@ -344,7 +344,6 @@
344 344  * (% style="color:#037691" %)**Timestamp: **(%%)0x6390453d =1670399293 (Unix Time)
345 345  
346 346  
347 -
348 348  == 2.4  Payload Explanation and Sensor Interface ==
349 349  
350 350  === 2.4.1  Device ID ===
... ... @@ -402,16 +402,16 @@
402 402  
403 403  [[image:1670407401682-959.png]]
404 404  
405 -**(% style="color:blue" %)Object1 Distance:**
400 +(% style="color:blue" %)**Object1 Distance:**
406 406  
407 407  Distance between sensor probe to the first object. (unit: cm)
408 408  
409 409  For example, if the data you get from the register is 0x02 0x05, the distance between the sensor and the measured object is
410 410  
411 -**(% style="color:blue" %)0205(H) = 517 (D) = 517 cm.**
406 +(% style="color:blue" %)**0205(H) = 517 (D) = 517 cm.**
412 412  
413 413  
414 -**(% style="color:blue" %)Object2 Distance:**
409 +(% style="color:blue" %)**Object2 Distance:**
415 415  
416 416  Distance between sensor probe to the second object. (unit: cm)
417 417  
... ... @@ -425,7 +425,7 @@
425 425  == 2.5  Downlink Payload ==
426 426  
427 427  
428 -By default, NDS03A prints the downlink payload to console port.
423 +By default, NMDS200 prints the downlink payload to console port.
429 429  
430 430  [[image:image-20221021111414-18.png]] ​
431 431  
... ... @@ -442,7 +442,7 @@
442 442  
443 443  * (% style="color:#037691" %)**Reset**
444 444  
445 -If payload = 0x04FF, it will reset the NDS03A
440 +If payload = 0x04FF, it will reset the NMDS200
446 446  
447 447  * (% style="color:#037691" %)**INTMOD**
448 448  
... ... @@ -452,50 +452,31 @@
452 452  == 2.6  ​LED Indicator ==
453 453  
454 454  
455 -The NDS03A has an internal LED which is to show the status of different states.
450 +The NMDS200 has an internal LED which is to show the status of different states.
456 456  
457 457  * When the device starts normally, the LED will light up for 1 second.
458 458  * After NDS03A join NB-IoT network. The LED will be ON for 3 seconds.
459 459  * For each uplink probe, LED will be on for 500ms.
460 460  
461 -== 2.7  Alarm Base on Timeout ==
462 462  
463 463  
464 -NDS03A can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
458 +== 2.7  Distance alarm function ==
465 465  
466 466  
467 -(% style="color:blue" %)**1. Keep Status: Status to be monitor**
461 +(% style="color:blue" %)**AT Command: AT+ALARM1=min,max**
468 468  
469 -Keep Status = 1: Monitor Close to Open event
463 +**Example 1:**
470 470  
471 -Keep Status = 0: Monitor Open to Close event
465 +AT+ ALARM1 =60,200  ~/~/ Alarm when moisture lower than 60.
472 472  
467 +AT+ ALARM2 =min,max
473 473  
474 -(% style="color:blue" %)**2. Keep Time: Timeout to send an Alarm**
475 475  
476 -Range 0 ~~ 65535(0xFFFF) seconds.
470 +**Example 2:**
477 477  
478 -If keep time = 0, Disable Alarm Base on Timeout feature.
472 +AT+ ALARM2 =200,1500  ~/~/ Alarm when temperature lower than 1500
479 479  
480 -If keep time > 0, device will monitor the keep status event and send an alarm when status doesn't change after timeout.
481 481  
482 -
483 -(% style="color:blue" %)**AT Command to configure:**
484 -
485 -(% style="color:blue" %)**PB14 PIN:**
486 -
487 -(% style="color:#037691" %)**AT+TTRIG=1,30** (%%) **~-~->**  When the **Keep Status** change from connected to disconnect, and device remains in disconnect status for more than 30 seconds. NDS03A will send an uplink packet, the [[Alarm bit>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.
488 -
489 -(% style="color:#037691" %)**AT+TTRIG=0,0 ** (%%) **~-~->** Default Value, disable timeout Alarm.
490 -
491 -
492 -(% style="color:blue" %)**PB15 PIN:**
493 -
494 -(% style="color:#037691" %)**AT+TTRIG2=1,30**
495 -
496 -(% style="color:#037691" %)**AT+TTRIG2=0,0 **
497 -
498 -
499 499  == 2.8  Set debug mode ==
500 500  
501 501  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0