Changes for page NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 17:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -673,13 +673,13 @@ 673 673 674 674 675 675 676 -== 2.1 6Battery Analysis ==676 +== 2.17 Battery Analysis == 677 677 678 678 679 -=== 2.1 6.1 Battery Type ===679 +=== 2.17.1 Battery Type === 680 680 681 681 682 -The CPN01battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.682 +The NDS03A battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 683 683 684 684 The battery is designed to last for several years depends on the actual use environment and update interval. 685 685 ... ... @@ -695,7 +695,7 @@ 695 695 696 696 697 697 698 -=== 2.1 6.2 Power consumption Analyze ===698 +=== 2.17.2 Power consumption Analyze === 699 699 700 700 701 701 Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. ... ... @@ -718,7 +718,7 @@ 718 718 719 719 720 720 721 -=== 2.1 6.3 Battery Note ===721 +=== 2.17.3 Battery Note === 722 722 723 723 724 724 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. ... ... @@ -725,7 +725,7 @@ 725 725 726 726 727 727 728 -=== 2.1 6.4 Replace the battery ===728 +=== 2.17.4 Replace the battery === 729 729 730 730 731 731 The default battery pack of CPN01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). ... ... @@ -739,7 +739,7 @@ 739 739 740 740 The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 741 741 742 -[[image:image-20221 021112006-28.png]] 742 +[[image:image-20221118094449-6.png]] 743 743 744 744 745 745 ... ... @@ -792,15 +792,21 @@ 792 792 793 793 AT+ DEBUG : Enable or Disable debug mode 794 794 795 -AT+ TTRIG : Get or Set Alarm Base on Timeout 795 +AT+ TTRIG1 : Get or Set PB14 PIN Alarm Base on Timeout 796 796 797 -AT+ TTR MOD: Get or Setthetriggerinterruptmode(0:falling,1:rising)797 +AT+ TTRIG2 : Get or Set PB15 PIN Alarm Base on Timeout 798 798 799 -AT+ ALCFLAGalculateflag799 +AT+COUNTMOD : Get or Set the count mode 800 800 801 -AT+ CLRCClearcurrentdoor open count801 +AT+TTRCHANNEL : Get or Set the number of interrupt channels 802 802 803 +AT+TTRALARM : Get or Set TTRIG1 of Alarm interval (unit: minute) 803 803 805 +AT+DISALARM : Enable/Disable Alarm for door open/close or water leak event 806 + 807 +AT+ CLRC : Clear current door open count 808 + 809 + 804 804 (% style="color:blue" %)**COAP Management** 805 805 806 806 AT+URI : Resource parameters ... ... @@ -842,7 +842,7 @@ 842 842 843 843 Please see this link for how to upgrade: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]] 844 844 845 -(% style="color:red" %)**Notice: **(% style="color:blue" %)** CPN01** (%%)**and (% style="color:blue" %)CPL01(%%)**(% style="color:blue" %) (%%)**share the same mother board. They use the same connection and method to update.**851 +(% style="color:red" %)**Notice: **(% style="color:blue" %)**NDS03A** (%%)**and (% style="color:blue" %)LDS03A(%%)**(% style="color:blue" %) (%%)**share the same mother board. They use the same connection and method to update.** 846 846 847 847 848 848 ... ... @@ -866,7 +866,7 @@ 866 866 = 7. Order Info = 867 867 868 868 869 -Part Number**:** CPN01875 +Part Number**:** NDS03A 870 870 871 871 872 872 ... ... @@ -875,7 +875,7 @@ 875 875 876 876 (% style="color:blue" %)**Package Includes**: 877 877 878 -* CPN01Open/Close Sensor x 1884 +* NDS03A Open/Close Door Sensor x 1 879 879 * External antenna x 1 880 880 881 881 (% style="color:blue" %)**Dimension and weight**:
- image-20221118094449-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.5 KB - Content