<
From version < 65.2 >
edited by Xiaoling
on 2022/11/18 09:38
To version < 65.1 >
edited by Xiaoling
on 2022/11/18 09:36
>
Change comment: Uploaded new attachment "image-20221118093658-4.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -520,7 +520,7 @@
520 520  
521 521  * (% style="color:#037691" %)**Reset**
522 522  
523 -If payload = 0x04FF, it will reset the NDS03A
523 +If payload = 0x04FF, it will reset the NSE01
524 524  
525 525  * (% style="color:#037691" %)**INTMOD**
526 526  
... ... @@ -531,17 +531,16 @@
531 531  == 2.6  ​LED Indicator ==
532 532  
533 533  
534 -The NDS03A has an internal LED which is to show the status of different states.
534 +The CPN01 has an internal LED which is to show the status of different states.
535 535  
536 536  * When the device starts normally, the LED will light up for 1 second.
537 537  * After CPN01 join NB-IoT network. The LED will be ON for 3 seconds.
538 538  * For each uplink probe, LED will be on for 500ms.
539 539  
540 -
541 541  == 2.7  Alarm Base on Timeout ==
542 542  
543 543  
544 -NDS03A can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
543 +CPN01 can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
545 545  
546 546  
547 547  (% style="color:blue" %)**1. Keep Status: Status to be monitor**
... ... @@ -557,25 +557,17 @@
557 557  
558 558  If keep time = 0, Disable Alarm Base on Timeout feature.
559 559  
560 -If keep time > 0, device will monitor the keep status event and send an alarm when status doesn't change after timeout.
559 +If keep time > 0, device will monitor the keep status event and send an alarm when status doesnt change after timeout.
561 561  
562 562  
563 563  (% style="color:blue" %)**AT Command to configure:**
564 564  
565 -(% style="color:blue" %)**PB14 PIN:**
566 -
567 567  (% style="color:#037691" %)**AT+TTRIG=1,30** (%%) **~-~->**  When the **Keep Status** change from connected to disconnect, and device remains in disconnect status for more than 30 seconds. CPN01 will send an uplink packet, the [[Alarm bit>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.
568 568  
569 569  (% style="color:#037691" %)**AT+TTRIG=0,0 ** (%%) **~-~->** Default Value, disable timeout Alarm.
570 570  
571 571  
572 -(% style="color:blue" %)**PB15 PIN:**
573 573  
574 -(% style="color:#037691" %)**AT+TTRIG2=1,30**
575 -
576 -(% style="color:#037691" %)**AT+TTRIG2=0,0 **
577 -
578 -
579 579  == 2.8  Set debug mode ==
580 580  
581 581  
... ... @@ -598,50 +598,50 @@
598 598  
599 599  
600 600  
601 -== 2.10  Count Mod ==
592 +== 2.10  Set trigger mode ==
602 602  
603 603  
604 -(% style="color:blue" %)**AT Command: AT+COUNTMOD**
595 +(% style="color:blue" %)**AT Command: AT+TTRMOD**
605 605  
606 -[[image:image-20221118092935-1.png]]
597 +Feature: Set the trigger interrupt mode.
607 607  
599 +[[image:image-20221021111552-20.png]]
608 608  
609 609  
610 -== 2.11  Interrupt Pin Channel Mod ==
611 611  
603 +== 2.11  Set the calculate flag ==
612 612  
613 -(% style="color:blue" %)**AT Command: AT+TTRCHANNEL**
614 614  
615 -[[image:image-20221118093144-2.png]]
606 +Feature: Set the calculate flag
616 616  
608 +(% style="color:blue" %)**AT Command: AT+CALCFLAG**
617 617  
610 +[[image:image-20221021111711-22.png]]
618 618  
619 -== 2.12 TTRIG1/2 timeout status alarm ==
620 620  
621 621  
622 -It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval.
614 +== 2.12 Set count number ==
623 623  
624 -(% style="color:blue" %)**AT Command: AT+TTRALARM**
625 625  
626 -[[image:image-20221118093512-3.png]]
617 +Feature: Manually set the count number
627 627  
619 +(% style="color:blue" %)**AT Command: AT+SETCNT**
628 628  
621 +[[image:image-20221021111748-24.png]]
629 629  
630 -== 2.13  Select counting mode ==
631 631  
632 632  
633 -(% style="color:blue" %)**AT Command: AT+TTRMODx=a,b**
625 +== 2.13  Set the number of data to be uploaded and the recording time ==
634 634  
635 635  
636 -When (% style="color:red" %)**a=0**(%%), the door is opened to count, and when (% style="color:red" %)**a=1**(%%),the closed door is counted.
628 +(% style="color:blue" %)**AT Command:**
637 637  
638 -When (% style="color:red" %)**b=0**(%%), it is the last door open duration, and when (% style="color:red" %)**b=1**(%%),the last door close duration.
630 +(% style="color:#037691" %)**AT+TR=900**        (%%)~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
639 639  
640 -[[image:image-20221118093658-4.png]]
632 +(% style="color:#037691" %)**AT+NOUD=8 ** (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
641 641  
642 642  
643 643  
644 -
645 645  == 2.14  Read or Clear cached data ==
646 646  
647 647  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0