<
From version < 63.1 >
edited by Xiaoling
on 2022/11/18 09:31
To version < 67.1 >
edited by Xiaoling
on 2022/11/18 09:44
>
Change comment: Uploaded new attachment "image-20221118094449-6.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -520,7 +520,7 @@
520 520  
521 521  * (% style="color:#037691" %)**Reset**
522 522  
523 -If payload = 0x04FF, it will reset the NSE01
523 +If payload = 0x04FF, it will reset the NDS03A
524 524  
525 525  * (% style="color:#037691" %)**INTMOD**
526 526  
... ... @@ -531,16 +531,17 @@
531 531  == 2.6  ​LED Indicator ==
532 532  
533 533  
534 -The CPN01 has an internal LED which is to show the status of different states.
534 +The NDS03A has an internal LED which is to show the status of different states.
535 535  
536 536  * When the device starts normally, the LED will light up for 1 second.
537 537  * After CPN01 join NB-IoT network. The LED will be ON for 3 seconds.
538 538  * For each uplink probe, LED will be on for 500ms.
539 539  
540 +
540 540  == 2.7  Alarm Base on Timeout ==
541 541  
542 542  
543 -CPN01 can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
544 +NDS03A can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
544 544  
545 545  
546 546  (% style="color:blue" %)**1. Keep Status: Status to be monitor**
... ... @@ -556,17 +556,25 @@
556 556  
557 557  If keep time = 0, Disable Alarm Base on Timeout feature.
558 558  
559 -If keep time > 0, device will monitor the keep status event and send an alarm when status doesnt change after timeout.
560 +If keep time > 0, device will monitor the keep status event and send an alarm when status doesn't change after timeout.
560 560  
561 561  
562 562  (% style="color:blue" %)**AT Command to configure:**
563 563  
565 +(% style="color:blue" %)**PB14 PIN:**
566 +
564 564  (% style="color:#037691" %)**AT+TTRIG=1,30** (%%) **~-~->**  When the **Keep Status** change from connected to disconnect, and device remains in disconnect status for more than 30 seconds. CPN01 will send an uplink packet, the [[Alarm bit>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.
565 565  
566 566  (% style="color:#037691" %)**AT+TTRIG=0,0 ** (%%) **~-~->** Default Value, disable timeout Alarm.
567 567  
568 568  
572 +(% style="color:blue" %)**PB15 PIN:**
569 569  
574 +(% style="color:#037691" %)**AT+TTRIG2=1,30**
575 +
576 +(% style="color:#037691" %)**AT+TTRIG2=0,0 **
577 +
578 +
570 570  == 2.8  Set debug mode ==
571 571  
572 572  
... ... @@ -589,64 +589,73 @@
589 589  
590 590  
591 591  
592 -== 2.10  Set trigger mode ==
601 +== 2.10  Count Mod ==
593 593  
594 594  
595 -(% style="color:blue" %)**AT Command: AT+TTRMOD**
604 +(% style="color:blue" %)**AT Command: AT+COUNTMOD**
596 596  
597 -Feature: Set the trigger interrupt mode.
606 +[[image:image-20221118092935-1.png]]
598 598  
599 -[[image:image-20221021111552-20.png]]
600 600  
601 601  
610 +== 2.11  Interrupt Pin Channel Mod ==
602 602  
603 -== 2.11  Set the calculate flag ==
604 604  
613 +(% style="color:blue" %)**AT Command: AT+TTRCHANNEL**
605 605  
606 -Feature: Set the calculate flag
615 +[[image:image-20221118093144-2.png]]
607 607  
608 -(% style="color:blue" %)**AT Command: AT+CALCFLAG**
609 609  
610 -[[image:image-20221021111711-22.png]]
611 611  
619 +== 2.12 TTRIG1/2 timeout status alarm ==
612 612  
613 613  
614 -== 2.12 Set count number ==
622 +It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval.
615 615  
624 +(% style="color:blue" %)**AT Command: AT+TTRALARM**
616 616  
617 -Feature: Manually set the count number
626 +[[image:image-20221118093512-3.png]]
618 618  
619 -(% style="color:blue" %)**AT Command: AT+SETCNT**
620 620  
621 -[[image:image-20221021111748-24.png]]
622 622  
630 +== 2.13  Select counting mode ==
623 623  
624 624  
625 -== 2.13  Set the number of data to be uploaded and the recording time ==
633 +(% style="color:blue" %)**AT Command: AT+TTRMODx=a,b**
626 626  
635 +When (% style="color:red" %)**a=0**(%%), the door is opened to count, and when (% style="color:red" %)**a=1**(%%),the closed door is counted.
627 627  
628 -(% style="color:blue" %)**AT Command:**
637 +When (% style="color:red" %)**b=0**(%%), it is the last door open duration, and when (% style="color:red" %)**b=1**(%%),the last door close duration.
629 629  
630 -(% style="color:#037691" %)**AT+TR=900**        (%%)~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
639 +[[image:image-20221118093658-4.png]]
631 631  
632 -(% style="color:#037691" %)**AT+NOUD=8 ** (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
633 633  
634 634  
635 635  
636 -== 2.14  Read or Clear cached data ==
644 +== 2.14  Set the number of data to be uploaded and the recording time ==
637 637  
638 638  
639 639  (% style="color:blue" %)**AT Command:**
640 640  
649 +(% style="color:#037691" %)**AT+TR=900**(%%)  ~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
650 +
651 +(% style="color:#037691" %)**AT+NOUD=8**(%%)** ** ~/~/  The device uploads 0 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
652 +
653 +
654 +== 2.15  Read or Clear cached data ==
655 +
656 +
657 +(% style="color:blue" %)**AT Command:**
658 +
641 641  (% style="color:#037691" %)**AT+CDP**  (%%) ~/~/ Read cached data
642 642  
643 643  (% style="color:#037691" %)**AT+CDP=0**  (%%) ~/~/ Clear cached data ​
644 644  
645 -[[image:image-20221021111810-25.png||height="364" width="797"]]
663 +[[image:image-20221118094227-5.png]]
646 646  
647 647  
648 648  
649 -== 2.15  ​Firmware Change Log ==
667 +== 2.16  ​Firmware Change Log ==
650 650  
651 651  
652 652  Download URL & Firmware Change log:  [[https:~~/~~/www.dropbox.com/sh/8p5nuvo6gh7je4n/AAAMP7MMusgbXMz9Ik7Ls03Ga?dl=0>>https://www.dropbox.com/sh/8p5nuvo6gh7je4n/AAAMP7MMusgbXMz9Ik7Ls03Ga?dl=0]]
image-20221118093512-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +9.5 KB
Content
image-20221118093658-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +12.7 KB
Content
image-20221118094227-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +29.2 KB
Content
image-20221118094449-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +76.5 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0