From version < 33.7 >
edited by Xiaoling
on 2022/09/23 15:45
To version < 34.1 >
edited by David Huang
on 2022/10/08 11:44
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.David
Content
... ... @@ -72,7 +72,6 @@
72 72  * - B28 @H-FDD: 700MHz
73 73  
74 74  
75 -
76 76  == 1.4  Probe Specification ==
77 77  
78 78  
... ... @@ -93,7 +93,6 @@
93 93  * Length: 3.5 meters
94 94  
95 95  
96 -
97 97  == 1.5 ​ Applications ==
98 98  
99 99  
... ... @@ -100,7 +100,6 @@
100 100  * Smart Agriculture
101 101  
102 102  
103 -
104 104  == 1.6  Pin mapping and power on ==
105 105  
106 106  
... ... @@ -317,7 +317,6 @@
317 317  * 8 sets of recorded data: Leaf Temperature, Leaf moisture,Time stamp : 010e022663154d77,.......
318 318  
319 319  
320 -
321 321  == 2.4  Payload Explanation and Sensor Interface ==
322 322  
323 323  
... ... @@ -486,7 +486,6 @@
486 486  * For each uplink probe, LED will be on for 500ms.
487 487  
488 488  
489 -
490 490  == 2.7  Installation ==
491 491  
492 492  
... ... @@ -539,7 +539,11 @@
539 539  * (% style="color:#037691" %)**AT+NOUD=8**  (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
540 540  
541 541  
537 +This link explains the relationship between TR, NOUD and TDC more clearly.
542 542  
539 +[[https:~~/~~/www.processon.com/view/link/6340e606e401fd390891af87>>https://www.processon.com/view/link/6340e606e401fd390891af87]]
540 +
541 +
543 543  == 2.10  Read or Clear cached data ==
544 544  
545 545  
... ... @@ -635,86 +635,86 @@
635 635  
636 636  See this link for detail:  [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
637 637  
638 -AT+<CMD>?  : Help on <CMD>
637 +AT+<CMD>?  :  Help on <CMD>
639 639  
640 -AT+<CMD>         : Run <CMD>
639 +AT+<CMD>  Run <CMD>
641 641  
642 -AT+<CMD>=<value> : Set the value
641 +AT+<CMD>=<value>:  Set the value
643 643  
644 -AT+<CMD>=?  : Get the value
643 +AT+<CMD>=?  Get the value
645 645  
646 646  
647 647  (% style="color:#037691" %)**General Commands**      
648 648  
649 -AT  : Attention       
648 +AT  Attention       
650 650  
651 -AT?  : Short Help     
650 +AT?  Short Help     
652 652  
653 -ATZ  : MCU Reset    
652 +ATZ  :  MCU Reset    
654 654  
655 -AT+TDC  : Application Data Transmission Interval
654 +AT+TDC  :  Application Data Transmission Interval
656 656  
657 -AT+CFG  : Print all configurations
656 +AT+CFG  :  Print all configurations
658 658  
659 -AT+CFGMOD           : Working mode selection
658 +AT+CFGMOD  :  Working mode selection
660 660  
661 -AT+INTMOD            : Set the trigger interrupt mode
660 +AT+INTMOD  :  Set the trigger interrupt mode
662 662  
663 -AT+5VT  : Set extend the time of 5V power  
662 +AT+5VT  :  Set extend the time of 5V power  
664 664  
665 -AT+PRO  : Choose agreement
664 +AT+PRO :  Choose agreement
666 666  
667 -AT+RXDL  : Extend the sending and receiving time
666 +AT+RXDL:  Extend the sending and receiving time
668 668  
669 -AT+SERVADDR  : Server Address
668 +AT+SERVADDR :  Server Address
670 670  
671 -AT+APN     : Get or set the APN
670 +AT+APN :  Get or set the APN
672 672  
673 -AT+FBAND   : Get or Set whether to automatically modify the frequency band
672 +AT+FBAND :  Get or Set whether to automatically modify the frequency band
674 674  
675 -AT+DNSCFG  : Get or Set DNS Server
674 +AT+DNSCFG : Get or Set DNS Server
676 676  
677 677  AT+GETSENSORVALUE   : Returns the current sensor measurement
678 678  
679 -AT+TR      : Get or Set record time"
678 +AT+TR :  Get or Set record time"
680 680  
681 -AT+NOUD      : Get or Set the number of data to be uploaded
680 +AT+NOUD :  Get or Set the number of data to be uploaded
682 682  
683 -AT+CDP     : Read or Clear cached data
682 +AT+CDP :  Read or Clear cached data
684 684  
685 -AT+TEMPALARM      : Get or Set alarm of temp
684 +AT+TEMPALARM :  Get or Set alarm of temp
686 686  
687 -AT+HUMALARM     : Get or Set alarm of PH
686 +AT+HUMALARM :  Get or Set alarm of humidity
688 688  
689 689  
690 690  (% style="color:#037691" %)**COAP Management**      
691 691  
692 -AT+URI            : Resource parameters
691 +AT+URI :  Resource parameters
693 693  
694 694  
695 695  (% style="color:#037691" %)**UDP Management**
696 696  
697 -AT+CFM          : Upload confirmation mode (only valid for UDP)
696 +AT+CFM :  Upload confirmation mode (only valid for UDP)
698 698  
699 699  
700 700  (% style="color:#037691" %)**MQTT Management**
701 701  
702 -AT+CLIENT               : Get or Set MQTT client
701 +AT+CLIENT  :  Get or Set MQTT client
703 703  
704 -AT+UNAME  : Get or Set MQTT Username
703 +AT+UNAME  : Get or Set MQTT Username
705 705  
706 -AT+PWD                  : Get or Set MQTT password
705 +AT+PWD  :  Get or Set MQTT password
707 707  
708 -AT+PUBTOPIC  : Get or Set MQTT publish topic
707 +AT+PUBTOPIC  :  Get or Set MQTT publish topic
709 709  
710 -AT+SUBTOPIC  : Get or Set MQTT subscription topic
709 +AT+SUBTOPIC :  Get or Set MQTT subscription topic
711 711  
712 712  
713 713  (% style="color:#037691" %)**Information**          
714 714  
715 -AT+FDR  : Factory Data Reset
714 +AT+FDR :  Factory Data Reset
716 716  
717 -AT+PWORD  : Serial Access Password
716 +AT+PWORD :  Serial Access Password
718 718  
719 719  
720 720  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0