Changes for page NLMS01-NB-IoT Leaf Moisture Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:54
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.David - Content
-
... ... @@ -72,7 +72,6 @@ 72 72 * - B28 @H-FDD: 700MHz 73 73 74 74 75 - 76 76 == 1.4 Probe Specification == 77 77 78 78 ... ... @@ -93,7 +93,6 @@ 93 93 * Length: 3.5 meters 94 94 95 95 96 - 97 97 == 1.5 Applications == 98 98 99 99 ... ... @@ -100,7 +100,6 @@ 100 100 * Smart Agriculture 101 101 102 102 103 - 104 104 == 1.6 Pin mapping and power on == 105 105 106 106 ... ... @@ -317,7 +317,6 @@ 317 317 * 8 sets of recorded data: Leaf Temperature, Leaf moisture,Time stamp : 010e022663154d77,....... 318 318 319 319 320 - 321 321 == 2.4 Payload Explanation and Sensor Interface == 322 322 323 323 ... ... @@ -486,7 +486,6 @@ 486 486 * For each uplink probe, LED will be on for 500ms. 487 487 488 488 489 - 490 490 == 2.7 Installation == 491 491 492 492 ... ... @@ -539,7 +539,11 @@ 539 539 * (% style="color:#037691" %)**AT+NOUD=8** (%%)~/~/ The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 540 540 541 541 537 +This link explains the relationship between TR, NOUD and TDC more clearly. 542 542 539 +[[https:~~/~~/www.processon.com/view/link/6340e606e401fd390891af87>>https://www.processon.com/view/link/6340e606e401fd390891af87]] 540 + 541 + 543 543 == 2.10 Read or Clear cached data == 544 544 545 545 ... ... @@ -635,86 +635,86 @@ 635 635 636 636 See this link for detail: [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 637 637 638 -AT+<CMD>? 637 +AT+<CMD>? : Help on <CMD> 639 639 640 -AT+<CMD> :Run <CMD>639 +AT+<CMD> : Run <CMD> 641 641 642 -AT+<CMD>=<value> 641 +AT+<CMD>=<value>: Set the value 643 643 644 -AT+<CMD>=? :Get the value643 +AT+<CMD>=? : Get the value 645 645 646 646 647 647 (% style="color:#037691" %)**General Commands** 648 648 649 -AT :Attention648 +AT : Attention 650 650 651 -AT? :Short Help650 +AT? : Short Help 652 652 653 -ATZ 652 +ATZ : MCU Reset 654 654 655 -AT+TDC 654 +AT+TDC : Application Data Transmission Interval 656 656 657 -AT+CFG 656 +AT+CFG : Print all configurations 658 658 659 -AT+CFGMOD 658 +AT+CFGMOD : Working mode selection 660 660 661 -AT+INTMOD 660 +AT+INTMOD : Set the trigger interrupt mode 662 662 663 -AT+5VT 662 +AT+5VT : Set extend the time of 5V power 664 664 665 -AT+PRO 664 +AT+PRO : Choose agreement 666 666 667 -AT+RXDL :Extend the sending and receiving time666 +AT+RXDL: Extend the sending and receiving time 668 668 669 -AT+SERVADDR 668 +AT+SERVADDR : Server Address 670 670 671 -AT+APN :Get or set the APN670 +AT+APN : Get or set the APN 672 672 673 -AT+FBAND :Get or Set whether to automatically modify the frequency band672 +AT+FBAND : Get or Set whether to automatically modify the frequency band 674 674 675 -AT+DNSCFG 674 +AT+DNSCFG : Get or Set DNS Server 676 676 677 677 AT+GETSENSORVALUE : Returns the current sensor measurement 678 678 679 -AT+TR 678 +AT+TR : Get or Set record time" 680 680 681 -AT+NOUD 680 +AT+NOUD : Get or Set the number of data to be uploaded 682 682 683 -AT+CDP 682 +AT+CDP : Read or Clear cached data 684 684 685 -AT+TEMPALARM 684 +AT+TEMPALARM : Get or Set alarm of temp 686 686 687 -AT+HUMALARM PH686 +AT+HUMALARM : Get or Set alarm of humidity 688 688 689 689 690 690 (% style="color:#037691" %)**COAP Management** 691 691 692 -AT+URI 691 +AT+URI : Resource parameters 693 693 694 694 695 695 (% style="color:#037691" %)**UDP Management** 696 696 697 -AT+CFM 696 +AT+CFM : Upload confirmation mode (only valid for UDP) 698 698 699 699 700 700 (% style="color:#037691" %)**MQTT Management** 701 701 702 -AT+CLIENT 701 +AT+CLIENT : Get or Set MQTT client 703 703 704 -AT+UNAME 703 +AT+UNAME : Get or Set MQTT Username 705 705 706 -AT+PWD 705 +AT+PWD : Get or Set MQTT password 707 707 708 -AT+PUBTOPIC 707 +AT+PUBTOPIC : Get or Set MQTT publish topic 709 709 710 -AT+SUBTOPIC :Get or Set MQTT subscription topic709 +AT+SUBTOPIC : Get or Set MQTT subscription topic 711 711 712 712 713 713 (% style="color:#037691" %)**Information** 714 714 715 -AT+FDR :Factory Data Reset714 +AT+FDR : Factory Data Reset 716 716 717 -AT+PWORD 716 +AT+PWORD : Serial Access Password 718 718 719 719 720 720