<
From version < 30.1 >
edited by Edwin Chen
on 2022/09/08 00:23
To version < 28.1 >
edited by David Huang
on 2022/09/07 17:56
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.David
Content
... ... @@ -241,10 +241,11 @@
241 241  
242 242  User can use below command to change the **uplink interval**.
243 243  
244 -* **AT+TDC=7200      ** ~/~/ Set Update Interval to 7200s (2 hour)
244 +* **AT+TDC=600      ** ~/~/ Set Update Interval to 600s
245 245  
246 -**NOTE: By default, the device will send an uplink message every 2 hour. Each Uplink Include 8 set of records in this 2 hour (15 minute interval / record).**
246 +**NOTE:**
247 247  
248 +**~1. By default, the device will send an uplink message every 2 hour.**
248 248  
249 249  == 2.3  Uplink Payload ==
250 250  
... ... @@ -261,19 +261,20 @@
261 261  
262 262  The payload is ASCII string, representative same HEX:
263 263  
264 -0x(% style="color:red" %)f868411056754138(% style="color:blue" %)0064(% style="color:green" %)0c78(% style="color:red" %)17(% style="color:blue" %)01(% style="color:green" %)00(% style="color:blue" %)**0225010b6315537b**010b0226631550fb**010e022663154d77**01110225631549f1**011502246315466b**01190223631542e5**011d022163153f62**011e022163153bde**011e022163153859**(%%)** **where:
265 +0xf86841105675413800640c781701000225010b6315537b010b0226631550fb010e022663154d7701110225631549f1011502246315466b01190223631542e5011d022163153f62011e022163153bde011e022163153859 where:
265 265  
266 -* (% style="color:red" %)Device ID: 0xf868411056754138 = f868411056754138
267 -* (% style="color:blue" %)Version: 0x0064=100=1.0.0
268 -* (% style="color:green" %)BAT: 0x0c78 = 3192 mV = 3.192V
269 -* (% style="color:red" %)Singal: 0x17 = 23
270 -* (% style="color:blue" %)Mod: 0x01 = 1
271 -* (% style="color:green" %)Interrupt: 0x00= 0
267 +* Device ID: 0xf868411056754138 = f868411056754138
268 +* Version: 0x0064=100=1.0.0
269 +
270 +* BAT: 0x0c78 = 3192 mV = 3.192V
271 +* Singal: 0x17 = 23
272 +* Mod: 0x01 = 1
273 +* Interrupt: 0x00= 0
272 272  * Leaf moisture: 0x0225= 549 = 54.9%
273 273  * Leaf Temperature:0x010B =267=26.7 °C
274 274  * Time stamp : 0x6315537b =1662342011
275 275  * Leaf Temperature, Leaf moisture,Time stamp : 010b0226631550fb
276 -* (% style="color:blue" %)8 sets of recorded data: Leaf Temperature, Leaf moisture,Time stamp : 010e022663154d77,.......
278 +* 8 sets of recorded data: Leaf Temperature, Leaf moisture,Time stamp : 010e022663154d77,.......
277 277  
278 278  == 2.4  Payload Explanation and Sensor Interface ==
279 279  
... ... @@ -635,3 +635,4 @@
635 635  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
636 636  
637 637  ​
640 +
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0