Changes for page NDS03A - Outdoor NB-IoT Open/Close Door Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:55
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -643,6 +643,30 @@ 643 643 644 644 (% style="color:blue" %)**AT Command: AT+TTRALARM** 645 645 646 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:495px" %) 647 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 246px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 92px;background-color:#D9E2F3;color:#0070C0" %)**Response** 648 +|(% style="width:157px" %)((( 649 +AT+TTRALARM=0 650 +)))|(% style="width:156px" %)((( 651 +disable continuous alarm 652 +)))|(% style="width:89px" %)((( 653 +((( 654 + 655 +))) 656 + 657 +((( 658 +OK 659 +))) 660 +))) 661 +|(% style="width:157px" %)((( 662 +AT+TTRALARM=60 663 +)))|(% style="width:156px" %)((( 664 + The alarm interval is 60 minutes (unit: minutes) 665 +)))|(% style="width:89px" %)((( 666 +OK 667 +))) 668 + 669 + 646 646 [[image:image-20221118093512-3.png]] 647 647 648 648