... ... @@ -370,7 +370,6 @@
370 370  )))
371 371  |(% style="width:98px" %)[[Time stamp>>||anchor="H2.4.10A0Timestamp"]]|(% style="width:115px" %)Door Status(pb14)|(% style="width:92px" %)door open num(pb14)|(% style="width:99px" %)last open time(pb14)|(% style="width:67px" %)Time stamp|(% style="width:74px" %)...
372 372  
373 -
374 374  (% style="color:blue" %)**When AT+TTRCHANNEL=2:**
375 375  
376 376  
... ... @@ -419,7 +419,6 @@
419 419  
420 420  * (% style="color:#037691" %)**Timestamp:**(%%) 0x637590df =1668649183 (Unix Time)
421 421  
422 -
423 423  == 2.4  Payload Explanation and Sensor Interface ==
424 424  
425 425  
... ... @@ -443,7 +443,7 @@
443 443  
444 444  Specify the software version: 0x64=100, which means firmware version 1.00.
445 445  
446 -For example 0x00 64 : This device is CPN01 with firmware version 1.0.0.
444 +For example 0x00 64 : This device is NDS03A 1 with firmware version 1.0.0.
447 447  
448 448  
449 449  
... ... @@ -450,7 +450,7 @@
450 450  === 2.4.3  Battery Info ===
451 451  
452 452  
453 -Check the battery voltage for CPN01.
451 +Check the battery voltage for NDS03A.
454 454  
455 455  Ex1: 0x0B45 = 2885mV
456 456  
... ... @@ -477,19 +477,17 @@
477 477  
478 478  
479 479  
480 -=== 2.4.5  Calculate Flag ===
478 +=== 2.4.5  Disalarm: (default: 0) ===
481 481  
482 482  
483 -The calculate flag is a user defined field, IoT server can use this filed to handle different meters with different pulse factors. For example, if there are 100 water meters, meter 1~~50 are 1 liter/pulse and meter 51 ~~ 100 has 1.5 liter/pulse.
481 +(% style="color:blue" %)**If Disalarm = 1**(%%), NDS03A will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many open/close event, and platform only care about the total number of pulse.
484 484  
485 -User can set calculate flag to 1 for meter 1~~50 and 2 for meter 51 ~~ 100, So IoT Server can use this field for calculation.
483 +(% style="color:blue" %)**If Disalarm = 0**(%%), NDS03A will send uplink at every TDC periodically and send data on each open/close event. This is useful for the application user need to monitor the open/close event in real-time.
486 486  
487 -Default value: 0. 
485 + (% style="color:red" %)**Note:**(%%) When Disalarm=0, a high frequently open/close event will cause lots of uplink and drain battery very fast.
488 488  
489 -Range (6 bits): (b)000000 ~~ (b) 111111
490 490  
491 491  
492 -
493 493  === 2.4.6  Alarm ===
494 494  
495 495  