From version < 59.2 >
edited by Xiaoling
on 2022/11/17 14:23
To version < 59.3 >
edited by Xiaoling
on 2022/11/17 14:34
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -186,7 +186,7 @@
186 186  
187 187  
188 188  
189 -== 2.2 ​ Configure CPN01 ==
189 +== 2.2 ​ Configure NDS03A ==
190 190  
191 191  === 2.2.1 Test Requirement ===
192 192  
... ... @@ -194,7 +194,7 @@
194 194  To use NDS03A in your city, make sure to meet below requirements:
195 195  
196 196  * Your local operator has already distributed an NB-IoT Network.
197 -* The local NB-IoT network used the band that CPN01 supports.
197 +* The local NB-IoT network used the band that NDS03A supports.
198 198  * Your operator is able to distribute the data received in their NB-IoT network to your IoT server.
199 199  
200 200  Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8.  The NDS03A will use** (% style="color:red" %)CoAP(120.24.4.116:5683)(%%)** or raw (% style="color:red" %)**UDP(120.24.4.116:5601) **(%%)or (% style="color:red" %)**MQTT(120.24.4.116:1883) **(%%)or (% style="color:red" %)**TCP(120.24.4.116:5600)protocol**(%%) to send data to the test server.
... ... @@ -215,10 +215,10 @@
215 215  
216 216  
217 217  
218 -=== 2.2.3 Connect USB – TTL to CPN01 and configure it ===
218 +=== 2.2.3 Connect USB – TTL to NDS03A and configure it ===
219 219  
220 220  
221 -User need to configure CPN01 via serial port to set the (% style="color:red" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. CPN01 support AT Commands, user can use a USB to TTL adapter to connect to CPN01 and use AT Commands to configure it, as below.
221 +User need to configure NDS03A via serial port to set the (% style="color:red" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. NDS03A support AT Commands, user can use a USB to TTL adapter to connect to NDS03A and use AT Commands to configure it, as below.
222 222  
223 223  (% style="color:blue" %)**Connection:**
224 224  
... ... @@ -241,11 +241,11 @@
241 241  
242 242  * Flow Control: (% style="color:red" %)**None**
243 243  
244 -Make sure the switch is in FLASH position, then power on CPN01 by connecting the (% style="color:orange" %)**Yellow Jumper**(%%).
244 +Make sure the switch is in FLASH position, then power on NDS03A by connecting the (% style="color:orange" %)**Yellow Jumper**(%%).
245 245  
246 246  ​[[image:image-20221021110817-7.png]]
247 247  
248 -CPN01 will output system info once powered on as below, we can enter the **password: 12345678** to access AT Command input.
248 +NDS03A will output system info once powered on as below, we can enter the **password: 12345678** to access AT Command input.
249 249  
250 250  
251 251  (% style="color:red" %)**Note: the valid AT Commands can be found at:  **(%%)[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
... ... @@ -271,7 +271,7 @@
271 271  [[image:image-20221021110948-8.png]]
272 272  
273 273  
274 -After configuring the server address and (% style="color:green" %)**reset CPN01**(%%) (via AT+ATZ ), CPN01 will start to uplink sensor values to the CoAP server.
274 +After configuring the server address and (% style="color:green" %)**reset CPN01**(%%) (via AT+ATZ ), NDS03A will start to uplink sensor values to the CoAP server.
275 275  
276 276  [[image:image-20221021110956-9.png]] ​
277 277  
... ... @@ -347,11 +347,11 @@
347 347  
348 348  User can use below command to change the (% style="color:blue" %)**uplink interval**.
349 349  
350 -* (% style="color:#037691" %)**AT+TDC=7200      ** (%%) ~/~/ Set Update Interval to 7200s (2 hours)
350 +* (% style="color:#037691" %)**AT+TDC=14400      ** (%%) ~/~/ Set Update Interval to 14400s (4 hours)
351 351  
352 352  (% style="color:red" %)**NOTE:**
353 353  
354 -1.  By default, the device will send an uplink message every 1 hour.
354 +1.  By default, the device will send an uplink message every 4 hour.
355 355  
356 356  
357 357  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0