Changes for page NDS03A - Outdoor NB-IoT Open/Close Door Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:55
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -33,7 +33,7 @@ 33 33 ))) 34 34 35 35 ((( 36 -NDS03A has the(% style="color:blue" %)**open alarm feature**(%%), user can set this feature so the device will send an alarm if the door has been open for a certain time. 36 +NDS03A has the (% style="color:blue" %)**open alarm feature**(%%), user can set this feature so the device will send an alarm if the door has been open for a certain time. 37 37 ))) 38 38 39 39 ((( ... ... @@ -95,7 +95,6 @@ 95 95 [[image:image-20221117115010-6.png]] 96 96 97 97 98 - 99 99 == 1.5 Applications == 100 100 101 101 ... ... @@ -102,7 +102,6 @@ 102 102 [[image:image-20221117114842-3.png]] 103 103 104 104 105 - 106 106 == 1.6 Specification == 107 107 108 108 ... ... @@ -246,7 +246,6 @@ 246 246 (% style="color:red" %)**Note: the valid AT Commands can be found at: **(%%)[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 247 247 248 248 249 - 250 250 === 2.2.4 Use CoAP protocol to uplink data === 251 251 252 252 ... ... @@ -308,7 +308,7 @@ 308 308 309 309 * (% style="color:#037691" %)**AT+SUBTOPIC=NSE01_SUB ** (%%) ~/~/ Set the subscription topic of MQTT 310 310 311 - [[image:image-20221208115608-3.png]]308 + [[image:image-20221208115608-3.png]] 312 312 313 313 314 314 [[image:image-20221118103453-8.png||height="608" width="841"]] ... ... @@ -327,7 +327,7 @@ 327 327 328 328 * (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5600 ** (%%) ~/~/ Set TCP server address and port 329 329 330 - [[image:image-20221208115624-4.png]]327 + [[image:image-20221208115624-4.png]] 331 331 332 332 333 333 [[image:image-20221208115640-5.png]] ... ... @@ -365,8 +365,6 @@ 365 365 ))) 366 366 |(% style="width:98px" %)[[Time stamp>>||anchor="H2.4.7A0Timestamp"]]|(% style="width:115px" %)Door Status(pb14)|(% style="width:92px" %)door open num(pb14)|(% style="width:99px" %)last open time(pb14)|(% style="width:67px" %)Time stamp|(% style="width:74px" %)... 367 367 368 - 369 - 370 370 (% style="color:blue" %)**When AT+TTRCHANNEL=2:** 371 371 372 372 (% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %) ... ... @@ -582,7 +582,6 @@ 582 582 [[image:image-20221021111629-21.png]] 583 583 584 584 585 - 586 586 == 2.9 Clear Flash Record == 587 587 588 588 ... ... @@ -661,71 +661,14 @@ 661 661 Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]] 662 662 663 663 664 -== 2.17 BatteryAnalysis==658 +== 2.17 Battery & Power Consumption == 665 665 666 -=== 2.17.1 Battery Type === 667 667 661 +NDS03A uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 668 668 669 - The NDS03A batteryisacombinationof an 8500mAh Li/SOCI2 Battery andaSuperCapacitor. The batteryisnon-rechargeablebattery typewithaow discharge rate(<2%per year). Thistypeofbatterys commonly used inIoT devicessuch as water meter.663 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 670 670 671 -The battery is designed to last for several years depends on the actual use environment and update interval. 672 672 673 -The battery-related documents as below: 674 - 675 -* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 676 - 677 -* [[Lithium-Thionyl Chloride Battery datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 678 - 679 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 680 - 681 -[[image:image-20221021111911-26.png]] 682 - 683 - 684 -=== 2.17.2 Power consumption Analyze === 685 - 686 - 687 -Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 688 - 689 -Instruction to use as below: 690 - 691 -(% style="color:blue" %)**Step 1: **(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 692 - 693 -(% style="color:blue" %)**Step 2: **(%%) Open it and choose 694 - 695 -* Product Model 696 - 697 -* Uplink Interval 698 - 699 -* Working Mode 700 - 701 -And the Life expectation in difference case will be shown on the right. 702 - 703 -[[image:1666596205057-567.png]] 704 - 705 - 706 -=== 2.17.3 Battery Note === 707 - 708 - 709 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 710 - 711 - 712 -=== 2.17.4 Replace the battery === 713 - 714 - 715 -The default battery pack of NDS03A includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). 716 - 717 - 718 -= 3. Access NB-IoT Module = 719 - 720 - 721 -Users can directly access the AT command set of the NB-IoT module. 722 - 723 -The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 724 - 725 - 726 -[[image:image-20221118094449-6.png]] 727 - 728 - 729 729 = 4. Using the AT Commands = 730 730 731 731 == 4.1 Access AT Commands ==