From version < 22.4 >
edited by Xiaoling
on 2022/06/06 16:44
To version < 22.6 >
edited by Xiaoling
on 2022/06/06 16:48
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -208,10 +208,9 @@
208 208  (% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.**
209 209  
210 210  
211 -1.
212 -11.
213 -111. Soil Temperature
214 214  
212 +=== 2.3.5 Soil Temperature ===
213 +
215 215   Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is
216 216  
217 217  **Example**:
... ... @@ -221,10 +221,9 @@
221 221  If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/100 = -1.29 °C
222 222  
223 223  
224 -1.
225 -11.
226 -111. Soil Conductivity (EC)
227 227  
224 +=== 2.3.6 Soil Conductivity (EC) ===
225 +
228 228  Obtain soluble salt concentration in soil or soluble ion concentration in liquid fertilizer or planting medium,. The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000).
229 229  
230 230  For example, if the data you get from the register is 0x00 0xC8, the soil conductivity is 00C8(H) = 200(D) = 200 uS/cm.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved