... ... @@ -66,11 +66,9 @@
66 66  
67 67  * Smart Agriculture
68 68  
69 -
70 70  (% class="wikigeneratedid" id="H200B1.5FirmwareChangelog" %)
71 71  ​
72 72  
73 -(% class="wikigeneratedid" %)
74 74  == 1.5 Firmware Change log ==
75 75  
76 76  
... ... @@ -204,15 +204,15 @@
204 204  
205 205  Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil.
206 206  
207 -For example, if the data you get from the register is 0x05 0xDC, the moisture content in the soil is
205 +For example, if the data you get from the register is __0x05 0xDC__, the moisture content in the soil is
208 208  
209 -**05DC(H) = 1500(D) /100 = 15%.**
210 210  
208 +(% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.**
211 211  
212 -1.
213 -11.
214 -111. Soil Temperature
215 215  
211 +
212 +=== 2.3.5 Soil Temperature ===
213 +
216 216   Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is
217 217  
218 218  **Example**:
... ... @@ -222,21 +222,31 @@
222 222  If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/100 = -1.29 °C
223 223  
224 224  
225 -1.
226 -11.
227 -111. Soil Conductivity (EC)
228 228  
229 -Obtain soluble salt concentration in soil or soluble ion concentration in liquid fertilizer or planting medium,. The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000).
224 +=== 2.3.6 Soil Conductivity (EC) ===
230 230  
226 +(((
227 +Obtain (% style="color:#4f81bd" %)**__soluble salt concentration__**(%%) in soil or (% style="color:#4f81bd" %)**__soluble ion concentration in liquid fertilizer__**(%%) or (% style="color:#4f81bd" %)**__planting medium__**(%%). The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000).
228 +)))
229 +
230 +(((
231 231  For example, if the data you get from the register is 0x00 0xC8, the soil conductivity is 00C8(H) = 200(D) = 200 uS/cm.
232 +)))
232 232  
233 -
234 +(((
234 234  Generally, the EC value of irrigation water is less than 800uS / cm.
236 +)))
235 235  
236 -1.
237 -11.
238 -111. MOD
238 +(((
239 +
240 +)))
239 239  
242 +(((
243 +
244 +)))
245 +
246 +=== 2.3.7 MOD ===
247 +
240 240  Firmware version at least v2.1 supports changing mode.
241 241  
242 242  For example, bytes[10]=90
... ... @@ -251,14 +251,13 @@
251 251  If** **payload =** **0x0A01, workmode=1
252 252  
253 253  
254 -1.
255 -11.
256 -111. ​Decode payload in The Things Network
257 257  
263 +=== 2.3.8 ​Decode payload in The Things Network ===
264 +
258 258  While using TTN network, you can add the payload format to decode the payload.
259 259  
260 260  
261 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image009.png]]
268 +[[image:1654505570700-128.png]]
262 262  
263 263  The payload decoder function for TTN is here:
264 264  