... ... @@ -54,7 +54,6 @@
54 54  * IP66 Waterproof Enclosure
55 55  * 4000mAh or 8500mAh Battery for long term use
56 56  
57 -
58 58  == 1.3 Specification ==
59 59  
60 60  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -67,7 +67,6 @@
67 67  
68 68  * Smart Agriculture
69 69  
70 -
71 71  == ​1.5 Firmware Change log ==
72 72  
73 73  
... ... @@ -179,7 +179,7 @@
179 179  
180 180  
181 181  1.
182 -11.
180 +11.
183 183  111. MOD=1(Original value)
184 184  
185 185  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
... ... @@ -202,7 +202,7 @@
202 202  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image008.png]]
203 203  
204 204  1.
205 -11.
203 +11.
206 206  111. Battery Info
207 207  
208 208  Check the battery voltage for LSE01.
... ... @@ -213,8 +213,8 @@
213 213  
214 214  
215 215  
216 -1.
217 -11.
214 +1.
215 +11.
218 218  111. Soil Moisture
219 219  
220 220  Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil.
... ... @@ -224,8 +224,8 @@
224 224  **05DC(H) = 1500(D) /100 = 15%.**
225 225  
226 226  
227 -1.
228 -11.
225 +1.
226 +11.
229 229  111. Soil Temperature
230 230  
231 231   Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is
... ... @@ -237,8 +237,8 @@
237 237  If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/100 = -1.29 °C
238 238  
239 239  
240 -1.
241 -11.
238 +1.
239 +11.
242 242  111. Soil Conductivity (EC)
243 243  
244 244  Obtain soluble salt concentration in soil or soluble ion concentration in liquid fertilizer or planting medium,. The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000).
... ... @@ -248,8 +248,8 @@
248 248  
249 249  Generally, the EC value of irrigation water is less than 800uS / cm.
250 250  
251 -1.
252 -11.
249 +1.
250 +11.
253 253  111. MOD
254 254  
255 255  Firmware version at least v2.1 supports changing mode.
... ... @@ -266,8 +266,8 @@
266 266  If** **payload =** **0x0A01, workmode=1
267 267  
268 268  
269 -1.
270 -11.
267 +1.
268 +11.
271 271  111. ​Decode payload in The Things Network
272 272  
273 273  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -280,7 +280,7 @@
280 280  LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
281 281  
282 282  
283 -1.
281 +1.
284 284  11. Uplink Interval
285 285  
286 286  The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
... ... @@ -287,7 +287,7 @@
287 287  
288 288  [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]]
289 289  
290 -1.
288 +1.
291 291  11. ​Downlink Payload
292 292  
293 293  By default, LSE50 prints the downlink payload to console port.
... ... @@ -320,7 +320,7 @@
320 320  
321 321  Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0
322 322  
323 -1.
321 +1.
324 324  11. ​Show Data in DataCake IoT Server
325 325  
326 326  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
... ... @@ -361,8 +361,8 @@
361 361  
362 362  The LSE01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
363 363  
364 -1.
365 -11.
362 +1.
363 +11.
366 366  111. EU863-870 (EU868)
367 367  
368 368  Uplink:
... ... @@ -393,8 +393,8 @@
393 393  869.525 - SF9BW125 (RX2 downlink only)
394 394  
395 395  
396 -1.
397 -11.
394 +1.
395 +11.
398 398  111. US902-928(US915)
399 399  
400 400  Used in USA, Canada and South America. Default use CHE=2
... ... @@ -439,8 +439,8 @@
439 439  923.3 - SF12BW500(RX2 downlink only)
440 440  
441 441  
442 -1.
443 -11.
440 +1.
441 +11.
444 444  111. CN470-510 (CN470)
445 445  
446 446  Used in China, Default use CHE=1
... ... @@ -485,8 +485,8 @@
485 485  505.3 - SF12BW125 (RX2 downlink only)
486 486  
487 487  
488 -1.
489 -11.
486 +1.
487 +11.
490 490  111. AU915-928(AU915)
491 491  
492 492  Default use CHE=2
... ... @@ -530,8 +530,8 @@
530 530  
531 531  923.3 - SF12BW500(RX2 downlink only)
532 532  
533 -1.
534 -11.
531 +1.
532 +11.
535 535  111. AS920-923 & AS923-925 (AS923)
536 536  
537 537  **Default Uplink channel:**
... ... @@ -583,8 +583,8 @@
583 583  923.2 - SF10BW125 (RX2)
584 584  
585 585  
586 -1.
587 -11.
584 +1.
585 +11.
588 588  111. KR920-923 (KR920)
589 589  
590 590  Default channel:
... ... @@ -620,8 +620,8 @@
620 620  921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
621 621  
622 622  
623 -1.
624 -11.
621 +1.
622 +11.
625 625  111. IN865-867 (IN865)
626 626  
627 627  Uplink:
... ... @@ -640,7 +640,7 @@
640 640  866.550 - SF10BW125 (RX2)
641 641  
642 642  
643 -1.
641 +1.
644 644  11. LED Indicator
645 645  
646 646  The LSE01 has an internal LED which is to show the status of different state.
... ... @@ -650,7 +650,7 @@
650 650  * Solid ON for 5 seconds once device successful Join the network.
651 651  * Blink once when device transmit a packet.
652 652  
653 -1.
651 +1.
654 654  11. Installation in Soil
655 655  
656 656  **Measurement the soil surface**
... ... @@ -677,7 +677,7 @@
677 677  
678 678  
679 679  
680 -1.
678 +1.
681 681  11. ​Firmware Change Log
682 682  
683 683  **Firmware download link:**
... ... @@ -696,7 +696,7 @@
696 696  
697 697  
698 698  
699 -1.
697 +1.
700 700  11. ​Battery Analysis
701 701  111. ​Battery Type
702 702  
... ... @@ -720,15 +720,15 @@
720 720  
721 721  
722 722  
723 -1.
724 -11.
721 +1.
722 +11.
725 725  111. ​Battery Note
726 726  
727 727  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
728 728  
729 729  
730 -1.
731 -11.
728 +1.
729 +11.
732 732  111. ​Replace the battery
733 733  
734 734  If Battery is lower than 2.7v, user should replace the battery of LSE01.