... ... @@ -55,8 +55,6 @@
55 55  * Micro SIM card slot for NB-IoT SIM
56 56  * 8500mAh Battery for long term use
57 57  
58 -
59 -
60 60  == 1.3  Specification ==
61 61  
62 62  
... ... @@ -85,11 +85,9 @@
85 85  (% style="color:#037691" %)**Power Consumption**
86 86  
87 87  * STOP Mode: 10uA @ 3.3v
88 -* Max transmit power: [[350mA@3.3v>>mailto:350mA@3.3v]]
86 +* Max transmit power: 350mA@3.3v
89 89  
90 90  
91 -
92 -
93 93  == ​1.4  Applications ==
94 94  
95 95  * Smart Buildings & Home Automation
... ... @@ -347,6 +347,7 @@
347 347  
348 348  
349 349  
346 +
350 350  == 2.4  Payload Explanation and Sensor Interface ==
351 351  
352 352  
... ... @@ -369,7 +369,7 @@
369 369  )))
370 370  
371 371  (((
372 -The Device ID is stored in a none-erase area, Upgrade the firmware or run **AT+FDR** won't erase Device ID.
369 +The Device ID is stored in a none-erase area, Upgrade the firmware or run AT+FDR won't erase Device ID.
373 373  )))
374 374  
375 375  
... ... @@ -381,7 +381,7 @@
381 381  )))
382 382  
383 383  (((
384 -For example: 0x00 64 : this device is NDDS75 with firmware version 1.0.0.
381 +For example: 0x00 64 : this device is NSE01 with firmware version 1.0.0.
385 385  )))
386 386  
387 387  
... ... @@ -436,17 +436,63 @@
436 436  
437 437  === 2.4.5  Soil Moisture ===
438 438  
439 -Get the distance. Flat object range 280mm - 7500mm.
436 +(((
437 +(((
438 +Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil.
439 +)))
440 +)))
440 440  
441 -For example, if the data you get from the register is **__0x0B 0x05__**, the distance between the sensor and the measured object is
442 +(((
443 +(((
444 +For example, if the data you get from the register is **__0x05 0xDC__**, the moisture content in the soil is
445 +)))
446 +)))
442 442  
443 443  (((
449 +
450 +)))
451 +
444 444  (((
445 -(% style="color:#4f81bd" %)** 0B05(H) = 2821(D) = 2821mm.**
453 +(% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.**
446 446  )))
455 +
456 +
457 +
458 +=== 2.4.6  Soil Temperature ===
459 +
460 +(((
461 +Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is __**0x09 0xEC**__, the temperature content in the soil is
447 447  )))
448 448  
449 449  (((
465 +**Example**:
466 +)))
467 +
468 +(((
469 +If payload is 0105H: ((0x0105 & 0x8000)>>15 === 0),temp = 0105(H)/100 = 2.61 °C
470 +)))
471 +
472 +(((
473 +If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/100 = -1.29 °C
474 +)))
475 +
476 +
477 +
478 +=== 2.4.7  Soil Conductivity (EC) ===
479 +
480 +(((
481 +Obtain (% style="color:#4f81bd" %)**__soluble salt concentration__**(%%) in soil or (% style="color:#4f81bd" %)**__soluble ion concentration in liquid fertilizer__**(%%) or (% style="color:#4f81bd" %)**__planting medium__**(%%). The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000).
482 +)))
483 +
484 +(((
485 +For example, if the data you get from the register is __**0x00 0xC8**__, the soil conductivity is 00C8(H) = 200(D) = 200 uS/cm.
486 +)))
487 +
488 +(((
489 +Generally, the EC value of irrigation water is less than 800uS / cm.
490 +)))
491 +
492 +(((
450 450  
451 451  )))
452 452  
... ... @@ -454,10 +454,10 @@
454 454  
455 455  )))
456 456  
457 -=== 2.4.6  Digital Interrupt ===
500 +=== 2.4.8  Digital Interrupt ===
458 458  
459 459  (((
460 -Digital Interrupt refers to pin (% style="color:blue" %)**GPIO_EXTI**(%%), and there are different trigger methods. When there is a trigger, the NDDS75 will send a packet to the server.
503 +Digital Interrupt refers to pin (% style="color:blue" %)**GPIO_EXTI**(%%), and there are different trigger methods. When there is a trigger, the NSE01 will send a packet to the server.
461 461  )))
462 462  
463 463  (((
... ... @@ -488,10 +488,10 @@
488 488  
489 489  
490 490  
491 -=== 2.4.7  ​+5V Output ===
534 +=== 2.4.9  ​+5V Output ===
492 492  
493 493  (((
494 -NDDS75 will enable +5V output before all sampling and disable the +5v after all sampling. 
537 +NSE01 will enable +5V output before all sampling and disable the +5v after all sampling. 
495 495  )))
496 496  
497 497  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved