From version < 91.1 >
edited by Xiaoling
on 2022/07/09 09:57
To version < 90.2 >
edited by Xiaoling
on 2022/07/09 09:45
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -366,7 +366,7 @@
366 366  )))
367 367  
368 368  (((
369 -The Device ID is stored in a none-erase area, Upgrade the firmware or run **AT+FDR** won't erase Device ID.
369 +The Device ID is stored in a none-erase area, Upgrade the firmware or run AT+FDR won't erase Device ID.
370 370  )))
371 371  
372 372  
... ... @@ -378,7 +378,7 @@
378 378  )))
379 379  
380 380  (((
381 -For example: 0x00 64 : this device is NDDS75 with firmware version 1.0.0.
381 +For example: 0x00 64 : this device is NSE01 with firmware version 1.0.0.
382 382  )))
383 383  
384 384  
... ... @@ -433,17 +433,63 @@
433 433  
434 434  === 2.4.5  Soil Moisture ===
435 435  
436 -Get the distance. Flat object range 280mm - 7500mm.
436 +(((
437 +(((
438 +Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil.
439 +)))
440 +)))
437 437  
438 -For example, if the data you get from the register is **__0x0B 0x05__**, the distance between the sensor and the measured object is
442 +(((
443 +(((
444 +For example, if the data you get from the register is **__0x05 0xDC__**, the moisture content in the soil is
445 +)))
446 +)))
439 439  
440 440  (((
449 +
450 +)))
451 +
441 441  (((
442 -(% style="color:#4f81bd" %)** 0B05(H) = 2821(D) = 2821mm.**
453 +(% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.**
443 443  )))
455 +
456 +
457 +
458 +=== 2.4.6  Soil Temperature ===
459 +
460 +(((
461 +Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is __**0x09 0xEC**__, the temperature content in the soil is
444 444  )))
445 445  
446 446  (((
465 +**Example**:
466 +)))
467 +
468 +(((
469 +If payload is 0105H: ((0x0105 & 0x8000)>>15 === 0),temp = 0105(H)/100 = 2.61 °C
470 +)))
471 +
472 +(((
473 +If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/100 = -1.29 °C
474 +)))
475 +
476 +
477 +
478 +=== 2.4.7  Soil Conductivity (EC) ===
479 +
480 +(((
481 +Obtain (% style="color:#4f81bd" %)**__soluble salt concentration__**(%%) in soil or (% style="color:#4f81bd" %)**__soluble ion concentration in liquid fertilizer__**(%%) or (% style="color:#4f81bd" %)**__planting medium__**(%%). The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000).
482 +)))
483 +
484 +(((
485 +For example, if the data you get from the register is __**0x00 0xC8**__, the soil conductivity is 00C8(H) = 200(D) = 200 uS/cm.
486 +)))
487 +
488 +(((
489 +Generally, the EC value of irrigation water is less than 800uS / cm.
490 +)))
491 +
492 +(((
447 447  
448 448  )))
449 449  
... ... @@ -451,10 +451,10 @@
451 451  
452 452  )))
453 453  
454 -=== 2.4.6  Digital Interrupt ===
500 +=== 2.4.8  Digital Interrupt ===
455 455  
456 456  (((
457 -Digital Interrupt refers to pin (% style="color:blue" %)**GPIO_EXTI**(%%), and there are different trigger methods. When there is a trigger, the NDDS75 will send a packet to the server.
503 +Digital Interrupt refers to pin (% style="color:blue" %)**GPIO_EXTI**(%%), and there are different trigger methods. When there is a trigger, the NSE01 will send a packet to the server.
458 458  )))
459 459  
460 460  (((
... ... @@ -485,10 +485,10 @@
485 485  
486 486  
487 487  
488 -=== 2.4.7  ​+5V Output ===
534 +=== 2.4.9  ​+5V Output ===
489 489  
490 490  (((
491 -NDDS75 will enable +5V output before all sampling and disable the +5v after all sampling. 
537 +NSE01 will enable +5V output before all sampling and disable the +5v after all sampling. 
492 492  )))
493 493  
494 494  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0