From version < 86.1 >
edited by Xiaoling
on 2022/07/09 09:35
To version < 86.2 >
edited by Xiaoling
on 2022/07/09 09:35
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -56,7 +56,6 @@
56 56  * 8500mAh Battery for long term use
57 57  
58 58  
59 -
60 60  == 1.3  Specification ==
61 61  
62 62  
... ... @@ -74,7 +74,6 @@
74 74  * - B20 @H-FDD: 800MHz
75 75  * - B28 @H-FDD: 700MHz
76 76  
77 -
78 78  (% style="color:#037691" %)**Battery:**
79 79  
80 80  * Li/SOCI2 un-chargeable battery
... ... @@ -83,7 +83,6 @@
83 83  * Max continuously current: 130mA
84 84  * Max boost current: 2A, 1 second
85 85  
86 -
87 87  (% style="color:#037691" %)**Power Consumption**
88 88  
89 89  * STOP Mode: 10uA @ 3.3v
... ... @@ -91,7 +91,6 @@
91 91  
92 92  
93 93  
94 -
95 95  == ​1.4  Applications ==
96 96  
97 97  * Smart Buildings & Home Automation
... ... @@ -113,7 +113,6 @@
113 113  
114 114  
115 115  
116 -
117 117  = 2.  Use NDDS75 to communicate with IoT Server =
118 118  
119 119  == 2.1  How it works ==
... ... @@ -227,31 +227,30 @@
227 227  
228 228  For parameter description, please refer to AT command set
229 229  
230 -[[image:1657249793983-486.png]]
225 +[[image:1657330452568-615.png]]
231 231  
232 232  
233 -After configure the server address and (% style="color:green" %)**reset the device**(%%) (via AT+ATZ ), NSE01 will start to uplink sensor values to CoAP server.
228 +After configure the server address and (% style="color:green" %)**reset the device**(%%) (via AT+ATZ ), NDDS75 will start to uplink sensor values to CoAP server.
234 234  
235 -[[image:1657249831934-534.png]]
230 +[[image:1657330472797-498.png]]
236 236  
237 237  
238 238  
239 239  === 2.2.5 Use UDP protocol to uplink data(Default protocol) ===
240 240  
241 -This feature is supported since firmware version v1.0.1
242 242  
243 -
244 244  * (% style="color:blue" %)**AT+PRO=2   ** (%%) ~/~/ Set to use UDP protocol to uplink
245 245  * (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5601   ** (%%) ~/~/ to set UDP server address and port
246 246  * (% style="color:blue" %)**AT+CFM=1       ** (%%) ~/~/If the server does not respond, this command is unnecessary
247 247  
248 -[[image:1657249864775-321.png]]
249 249  
242 +[[image:1657330501006-241.png]]
250 250  
251 -[[image:1657249930215-289.png]]
252 252  
245 +[[image:1657330533775-472.png]]
253 253  
254 254  
248 +
255 255  === 2.2.6 Use MQTT protocol to uplink data ===
256 256  
257 257  This feature is supported since firmware version v110
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0