490 490  
491 491  === 2.4.8  Digital Interrupt ===
492 492  
493 +(((
493 493  Digital Interrupt refers to pin (% style="color:blue" %)**GPIO_EXTI**(%%), and there are different trigger methods. When there is a trigger, the NSE01 will send a packet to the server.
495 +)))
494 494  
497 +(((
495 495  The command is:
499 +)))
496 496  
501 +(((
497 497  (% style="color:blue" %)**AT+INTMOD=3 **(%%) ~/~/(more info about INMOD please refer [[**AT Command Manual**>>url:https://www.dragino.com/downloads/downloads/NB-IoT/NBSN95/DRAGINO_NBSN95-NB_AT%20Commands_v1.1.0.pdf]])**.**
503 +)))
498 498  
499 499  
506 +(((
500 500  The lower four bits of this data field shows if this packet is generated by interrupt or not. Click here for the hardware and software set up.
508 +)))
501 501  
502 502  
511 +(((
503 503  Example:
513 +)))
504 504  
515 +(((
505 505  0x(00): Normal uplink packet.
517 +)))
506 506  
519 +(((
507 507  0x(01): Interrupt Uplink Packet.
521 +)))
508 508  
509 509  
510 510  
511 511  === 2.4.9  ​+5V Output ===
512 512  
527 +(((
513 513  NSE01 will enable +5V output before all sampling and disable the +5v after all sampling. 
529 +)))
514 514  
515 515  
532 +(((
516 516  The 5V output time can be controlled by AT Command.
534 +)))
517 517  
536 +(((
518 518  (% style="color:blue" %)**AT+5VT=1000**
538 +)))
519 519  
540 +(((
520 520  Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.
542 +)))