From version < 6.2 >
edited by Xiaoling
on 2022/06/06 15:36
To version < 6.1 >
edited by Xiaoling
on 2022/06/06 15:35
>
Change comment: Uploaded new attachment "1654500929571-736.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -87,6 +87,8 @@
87 87  **Method**
88 88  )))|**FDR , with temperature &EC compensate**|**Conductivity , with temperature compensate**|**RTD, and calibrate**
89 89  
90 +
91 +
90 90  *
91 91  *1. ​Applications
92 92  * Smart Agriculture
... ... @@ -98,6 +98,8 @@
98 98  
99 99  * Release
100 100  
103 +
104 +
101 101  1. Configure LSE01 to connect to LoRaWAN network
102 102  11. How it works
103 103  
... ... @@ -148,6 +148,8 @@
148 148  )))
149 149  
150 150  
155 +
156 +
151 151  **Step 2**: Power on LSE01
152 152  
153 153  
... ... @@ -734,6 +734,7 @@
734 734  * [[Lithium-Thionyl Chloride Battery>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/ER18505_datasheet-EN.pdf]] datasheet, [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/ER18505_datasheet_PM-ER18505-S-02-LF_EN.pdf]]
735 735  * [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
736 736  
743 +
737 737  |(((
738 738  JST-XH-2P connector
739 739  )))
... ... @@ -972,6 +972,8 @@
972 972  
973 973  
974 974  
982 +
983 +
975 975  = 5. Trouble Shooting =
976 976  
977 977  
... ... @@ -982,26 +982,26 @@
982 982  
983 983  == 5.2 AT Command input doesn’t work ==
984 984  
985 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
994 +In the case if user can see the console output but can’t type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn’t send **ENTER** while press the send key, user need to add ENTER in their string.
986 986  
987 987  
988 988  == 5.3 Device rejoin in at the second uplink packet ==
989 989  
990 -(% style="color:#4f81bd" %)**Issue describe as below:**
999 +**Issue describe as below:**
991 991  
992 -[[image:1654500909990-784.png]]
1001 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]]
993 993  
994 994  
995 -(% style="color:#4f81bd" %)**Cause for this issue:**
1004 +**Cause for this issue:**
996 996  
997 997  The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin.
998 998  
999 999  
1000 -(% style="color:#4f81bd" %)**Solution: **
1009 +**Solution: **
1001 1001  
1002 1002  All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
1003 1003  
1004 -[[image:1654500929571-736.png]]
1013 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
1005 1005  
1006 1006  
1007 1007  = 6. ​Order Info =
... ... @@ -1026,6 +1026,7 @@
1026 1026  * (% style="color:red" %)**4**(%%): 4000mAh battery
1027 1027  * (% style="color:red" %)**8**(%%): 8500mAh battery
1028 1028  
1038 +
1029 1029  = 7. Packing Info =
1030 1030  
1031 1031  (((
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved