Changes for page N95S31B -- NB-IoT Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:44
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -143,9 +143,7 @@ 143 143 144 144 145 145 146 -1. 147 -11. 148 -111. Insert SIM card 146 +=== 2.2.2 Insert SIM card === 149 149 150 150 Insert the NB-IoT Card get from your provider. 151 151 ... ... @@ -156,12 +156,10 @@ 156 156 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image004.gif]] 157 157 158 158 159 -1. 160 -11. 161 -111. Connect USB – TTL to NSE01 to configure it 157 +=== 2.2.3 Connect USB – TTL to NSE01 to configure it === 162 162 163 163 164 -User need to configure NSE01 via serial port to set the **Server Address** / **Uplink Topic** to define where and how-to uplink packets. NSE01 support AT Commands, user can use a USB to TTL adapter to connect to NSE01 and use AT Commands to configure it, as below. 160 +User need to configure NSE01 via serial port to set the **(% style="color:blue" %)Server Address** / **Uplink Topic** (%%)to define where and how-to uplink packets. NSE01 support AT Commands, user can use a USB to TTL adapter to connect to NSE01 and use AT Commands to configure it, as below. 165 165 166 166 167 167 ... ... @@ -168,24 +168,24 @@ 168 168 169 169 Connection: 170 170 171 -USB TTL GND <~-~-~-~-> GND 167 + (% style="background-color:yellow" %)USB TTL GND <~-~-~-~-> GND 172 172 173 -USB TTL TXD <~-~-~-~-> UART_RXD 169 + (% style="background-color:yellow" %)USB TTL TXD <~-~-~-~-> UART_RXD 174 174 175 -USB TTL RXD <~-~-~-~-> UART_TXD 171 + (% style="background-color:yellow" %)USB TTL RXD <~-~-~-~-> UART_TXD 176 176 177 177 178 178 179 179 In the PC, use below serial tool settings: 180 180 181 -* Baud: **9600** 182 -* Data bits:** 8** 183 -* Stop bits: **1** 184 -* Parity: **None** 185 -* Flow Control: **None** 177 +* Baud: ** (% style="background-color:green" %)9600**(%%) 178 +* Data bits:** (% style="background-color:green" %)8**(%%) 179 +* Stop bits: **(% style="background-color:green" %)1**(%%) 180 +* Parity: **(% style="background-color:green" %)None**(%%) 181 +* Flow Control: **(% style="background-color:green" %)None** 186 186 187 187 188 -Make sure the switch is in FLASH position, then power on device by connecting the jumper on NSE01. NSE01 will output system info once power on as below, we can enter the **password: 12345678** to access AT Command input. 184 +Make sure the switch is in FLASH position, then power on device by connecting the jumper on NSE01. NSE01 will output system info once power on as below, we can enter the **(% style="background-color:green" %)password: 12345678**(%%) to access AT Command input. 189 189 190 190 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image009.jpg]] 191 191 ... ... @@ -194,21 +194,20 @@ 194 194 [[http:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/NSE01/>>url:http://www.dragino.com/downloads/index.php?dir=NB-IoT/NBSN50/]] 195 195 196 196 197 -1. 198 -11. 199 -111. Use CoAP protocol to uplink data 200 200 194 +=== 2.2.4 Use CoAP protocol to uplink data === 201 201 202 -Note: if you don’t have CoAP server, you can refer this link to set up one: 203 203 197 +(% style="background-color:red" %)Note: if you don’t have CoAP server, you can refer this link to set up one: 198 + 204 204 [[http:~~/~~/wiki.dragino.com/index.php?title=Set_up_CoAP_Server>>url:http://wiki.dragino.com/index.php?title=Set_up_CoAP_Server]] 205 205 206 206 207 207 Use below commands: 208 208 209 -* **AT+PRO=1** ~/~/ Set to use CoAP protocol to uplink 210 -* **AT+SERVADDR=120.24.4.116,5683 **~/~/ to set CoAP server address and port 211 -* **AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" **~/~/Set COAP resource path204 +* **(% style="color:blue" %)AT+PRO=1** (%%) ~/~/ Set to use CoAP protocol to uplink 205 +* **(% style="color:blue" %)AT+SERVADDR=120.24.4.116,5683 ** (%%)~/~/ to set CoAP server address and port 206 +* **(% style="color:blue" %)AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** (%%) ~/~/Set COAP resource path 212 212 213 213 214 214 For parameter description, please refer to AT command set ... ... @@ -216,15 +216,14 @@ 216 216 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image011.jpg]] 217 217 218 218 219 -After configure the server address and **reset the device** (via AT+ATZ ), NSE01 will start to uplink sensor values to CoAP server. 214 +After configure the server address and **(% style="color:green" %)reset the device**(%%) (via AT+ATZ ), NSE01 will start to uplink sensor values to CoAP server. 220 220 221 221 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image013.jpg]] 222 222 223 -1. 224 -11. 225 -111. Use UDP protocol to uplink data(Default protocol) 226 226 219 +=== 2.2.5 Use UDP protocol to uplink data(Default protocol) === 227 227 221 + 228 228 This feature is supported since firmware version v1.0.1 229 229 230 230