From version < 40.6 >
edited by Xiaoling
on 2022/06/30 11:05
To version < 40.3 >
edited by Xiaoling
on 2022/06/30 10:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -69,6 +69,7 @@
69 69  * 4000mAh or 8500mAh Battery for long term use
70 70  
71 71  
72 +
72 72  == 1.3 Specification ==
73 73  
74 74  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -179,6 +179,7 @@
179 179  )))
180 180  
181 181  
183 +
182 182  === 2.3.2 MOD~=1(Original value) ===
183 183  
184 184  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
... ... @@ -200,6 +200,7 @@
200 200  )))
201 201  
202 202  
205 +
203 203  === 2.3.3 Battery Info ===
204 204  
205 205  (((
... ... @@ -325,7 +325,7 @@
325 325  
326 326  
327 327  (((
328 -(% style="color:blue" %)**Examples:**
331 +**Examples:**
329 329  )))
330 330  
331 331  (((
... ... @@ -333,7 +333,7 @@
333 333  )))
334 334  
335 335  * (((
336 -(% style="color:blue" %)**Set TDC**
339 +**Set TDC**
337 337  )))
338 338  
339 339  (((
... ... @@ -353,7 +353,7 @@
353 353  )))
354 354  
355 355  * (((
356 -(% style="color:blue" %)**Reset**
359 +**Reset**
357 357  )))
358 358  
359 359  (((
... ... @@ -361,7 +361,7 @@
361 361  )))
362 362  
363 363  
364 -* (% style="color:blue" %)**CFM**
367 +* **CFM**
365 365  
366 366  Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0
367 367  
... ... @@ -1017,15 +1017,15 @@
1017 1017  
1018 1018  = 5. Trouble Shooting =
1019 1019  
1020 -== 5.1 ​Why I can't join TTN in US915 / AU915 bands? ==
1023 +== 5.1 ​Why I cant join TTN in US915 / AU915 bands? ==
1021 1021  
1022 -It is due to channel mapping. Please see the [[Eight Channel Mode>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.19EightChannelMode||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] section above for details.
1025 +It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] section above for details.
1023 1023  
1024 1024  
1025 -== 5.2 AT Command input doesn't work ==
1028 +== 5.2 AT Command input doesnt work ==
1026 1026  
1027 1027  (((
1028 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1031 +In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1029 1029  )))
1030 1030  
1031 1031  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0