196 196  === 2.3.3 Battery Info ===
197 197  
198 +(((
198 198  Check the battery voltage for LSE01.
200 +)))
199 199  
202 +(((
200 200  Ex1: 0x0B45 = 2885mV
204 +)))
201 201  
206 +(((
202 202  Ex2: 0x0B49 = 2889mV
208 +)))
203 203  
204 204  
205 205  
206 206  === 2.3.4 Soil Moisture ===
207 207  
214 +(((
208 208  Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil.
216 +)))
209 209  
218 +(((
210 210  For example, if the data you get from the register is __0x05 0xDC__, the moisture content in the soil is
220 +)))
211 211  
222 +(((
223 +
224 +)))
212 212  
226 +(((
213 213  (% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.**
228 +)))
214 214  
215 215  
216 216  
217 217  === 2.3.5 Soil Temperature ===
218 218  
234 +(((
219 219   Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is
236 +)))
220 220  
238 +(((
221 221  **Example**:
240 +)))
222 222  
242 +(((
223 223  If payload is 0105H: ((0x0105 & 0x8000)>>15 === 0),temp = 0105(H)/100 = 2.61 °C
244 +)))
224 224  
246 +(((
225 225  If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/100 = -1.29 °C
248 +)))
226 226  