From version < 32.3 >
edited by Xiaoling
on 2022/06/07 11:28
To version < 32.7 >
edited by Xiaoling
on 2022/06/07 11:35
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -58,7 +58,6 @@
58 58  * IP66 Waterproof Enclosure
59 59  * 4000mAh or 8500mAh Battery for long term use
60 60  
61 -
62 62  == 1.3 Specification ==
63 63  
64 64  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -143,6 +143,9 @@
143 143  
144 144  == 2.3 Uplink Payload ==
145 145  
145 +(% class="wikigeneratedid" %)
146 +=== ===
147 +
146 146  === 2.3.1 MOD~=0(Default Mode) ===
147 147  
148 148  LSE01 will uplink payload via LoRaWAN with below payload format: 
... ... @@ -150,6 +150,7 @@
150 150  
151 151  Uplink payload includes in total 11 bytes.
152 152  
155 +
153 153  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
154 154  |(((
155 155  **Size**
... ... @@ -156,11 +156,11 @@
156 156  
157 157  **(bytes)**
158 158  )))|**2**|**2**|**2**|**2**|**2**|**1**
159 -|**Value**|[[BAT>>path:#bat]]|(((
162 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
160 160  Temperature
161 161  
162 162  (Reserve, Ignore now)
163 -)))|[[Soil Moisture>>path:#soil_moisture]]|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]]|(((
166 +)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(((
164 164  MOD & Digital Interrupt
165 165  
166 166  (Optional)
... ... @@ -168,8 +168,6 @@
168 168  
169 169  
170 170  
171 -
172 -
173 173  === 2.3.2 MOD~=1(Original value) ===
174 174  
175 175  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
... ... @@ -180,11 +180,11 @@
180 180  
181 181  **(bytes)**
182 182  )))|**2**|**2**|**2**|**2**|**2**|**1**
183 -|**Value**|[[BAT>>path:#bat]]|(((
184 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
184 184  Temperature
185 185  
186 186  (Reserve, Ignore now)
187 -)))|[[Soil Moisture>>path:#soil_moisture]](raw)|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]](raw)|(((
188 +)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
188 188  MOD & Digital Interrupt
189 189  
190 190  (Optional)
... ... @@ -192,7 +192,6 @@
192 192  
193 193  
194 194  
195 -
196 196  === 2.3.3 Battery Info ===
197 197  
198 198  Check the battery voltage for LSE01.
... ... @@ -629,6 +629,8 @@
629 629  * Solid ON for 5 seconds once device successful Join the network.
630 630  * Blink once when device transmit a packet.
631 631  
632 +
633 +
632 632  == 2.9 Installation in Soil ==
633 633  
634 634  **Measurement the soil surface**
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0