From version < 32.11 >
edited by Xiaoling
on 2022/06/07 11:39
To version < 32.9 >
edited by Xiaoling
on 2022/06/07 11:38
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -195,57 +195,34 @@
195 195  
196 196  === 2.3.3 Battery Info ===
197 197  
198 -(((
199 199  Check the battery voltage for LSE01.
200 -)))
201 201  
202 -(((
203 203  Ex1: 0x0B45 = 2885mV
204 -)))
205 205  
206 -(((
207 207  Ex2: 0x0B49 = 2889mV
208 -)))
209 209  
210 210  
211 211  
212 212  === 2.3.4 Soil Moisture ===
213 213  
214 -(((
215 215  Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil.
216 -)))
217 217  
218 -(((
219 219  For example, if the data you get from the register is __0x05 0xDC__, the moisture content in the soil is
220 -)))
221 221  
222 -(((
223 -
224 -)))
225 225  
226 -(((
227 227  (% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.**
228 -)))
229 229  
230 230  
231 231  
232 232  === 2.3.5 Soil Temperature ===
233 233  
234 -(((
235 235   Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is
236 -)))
237 237  
238 -(((
239 239  **Example**:
240 -)))
241 241  
242 -(((
243 243  If payload is 0105H: ((0x0105 & 0x8000)>>15 === 0),temp = 0105(H)/100 = 2.61 °C
244 -)))
245 245  
246 -(((
247 247  If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/100 = -1.29 °C
248 -)))
249 249  
250 250  