... ... @@ -211,15 +211,15 @@
211 211  
212 212  
213 213  
214 -=== 2.2.3 Connect USB – TTL to NDDS75 to configure it ===
214 +=== 2.2. Connect USB – TTL to N95S31B to configure it ===
215 215  
216 216  (((
217 217  (((
218 -User need to configure NDDS75 via serial port to set the (% style="color:blue" %)**Server Address** / **Uplink Topic** (%%)to define where and how-to uplink packets. NDDS75 support AT Commands, user can use a USB to TTL adapter to connect to NDDS75 and use AT Commands to configure it, as below.
218 +User need to configure N95S31B via serial port to set the (% style="color:blue" %)**Server Address** / **Uplink Topic** (%%)to define where and how-to uplink packets. N95S31B support AT Commands, user can use a USB to TTL adapter to connect to N95S31B and use AT Commands to configure it, as below.
219 219  )))
220 220  )))
221 221  
222 -[[image:image-20220709092052-2.png]]
222 +[[image:1657351312545-300.png]]
223 223  
224 224  **Connection:**
225 225  
... ... @@ -239,18 +239,18 @@
239 239  * Flow Control: (% style="color:green" %)**None**
240 240  
241 241  (((
242 -Make sure the switch is in FLASH position, then power on device by connecting the jumper on NDDS75. NDDS75 will output system info once power on as below, we can enter the (% style="color:green" %)**password: 12345678**(%%) to access AT Command input.
242 +Make sure the switch is in FLASH position, then power on device by connecting the jumper on N95S31B. N95S31B will output system info once power on as below, we can enter the (% style="color:green" %)**password: 12345678**(%%) to access AT Command input.
243 243  )))
244 244  
245 245  [[image:1657329814315-101.png]]
246 246  
247 247  (((
248 -(% style="color:red" %)Note: the valid AT Commands can be found at: (%%)[[https:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/NDDS75/>>url:https://www.dragino.com/downloads/index.php?dir=NB-IoT/NDDS75/]]
248 +(% style="color:red" %)Note: the valid AT Commands can be found at:  (%%)[[https:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/N95S31B/>>url:https://www.dragino.com/downloads/index.php?dir=NB-IoT/N95S31B/]]
249 249  )))
250 250  
251 251  
252 252  
253 -=== 2.2.4 Use CoAP protocol to uplink data ===
253 +=== 2.2. Use CoAP protocol to uplink data ===
254 254  
255 255  (% style="color:red" %)Note: if you don't have CoAP server, you can refer this link to set up one: (%%)[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/>>http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]
256 256  
... ... @@ -270,10 +270,12 @@
270 270  )))
271 271  
272 272  (((
273 +
274 +
273 273  For parameter description, please refer to AT command set
274 274  )))
275 275  
276 -[[image:1657330452568-615.png]]
278 +[[image:1657352146020-183.png]]
277 277  
278 278  
279 279  (((
... ... @@ -280,11 +280,11 @@
280 280  After configure the server address and (% style="color:green" %)**reset the device**(%%) (via AT+ATZ ), NDDS75 will start to uplink sensor values to CoAP server.
281 281  )))
282 282  
283 -[[image:1657330472797-498.png]]
285 +[[image:1657352185396-303.png]]
284 284  
285 285  
286 286  
287 -=== 2.2.5 Use UDP protocol to uplink data(Default protocol) ===
289 +=== 2.2. Use UDP protocol to uplink data(Default protocol) ===
288 288  
289 289  
290 290  * (% style="color:blue" %)**AT+PRO=2   ** (%%) ~/~/ Set to use UDP protocol to uplink
1657352146020-183.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +264.0 KB
Content
1657352185396-303.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +98.3 KB
Content