Show last authors
1 (% style="text-align:center" %)
2 [[image:1654592399090-860.png||height="521" width="483"]]
3
4
5
6
7 **Table of Contents:**
8
9 * [[1. Introduction>>path:#H1.Introduction]]
10 ** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 ** [[​1.2 Features>>path:#H200B1.2Features]]
12 ** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 ** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 ** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 * [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 ** [[2.1 How it works>>path:#H2.1Howitworks]]
17 ** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 ** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 *** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 *** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 *** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 *** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 *** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 *** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 *** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 ** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 ** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 ** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 *** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 *** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 *** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 ** [[2.7 Calibration>>path:#H2.7Calibration]]
33 ** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 *** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 *** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 *** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 *** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 *** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 *** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 *** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 ** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 ** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 * [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 ** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 ** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 ** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 ** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 * [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 ** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 ** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 ** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 *** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 *** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 * [[5. Use AT Command>>path:#H5.UseATCommand]]
55 ** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 * [[6. FAQ>>path:#H6.FAQ]]
57 ** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 * [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 ** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 * [[8. Order Info>>path:#H8.OrderInfo]]
61 * [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 * [[10. ​Support>>path:#H10.A0200BSupport]]
63
64
65
66
67
68 = 1. Introduction =
69
70 == 1.1 ​What is LoRaWAN Soil pH Sensor ==
71
72 (((
73
74
75 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
76 )))
77
78 (((
79 LSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:#4f81bd" %)pH (%%)**with high accuracy and stable value. The LSPH01 probe can be buried into soil for long time use.
80 )))
81
82 (((
83 The LoRa wireless technology used in LSPH01 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
84 )))
85
86 (((
87 LSPH01 is powered by (% style="color:#4f81bd" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
88 )))
89
90 (((
91 Each LSPH01 is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
92 )))
93
94
95 [[image:1654592435432-887.png]]
96
97
98
99
100 == ​1.2 Features ==
101
102 * LoRaWAN 1.0.3 Class A
103 * Ultra-low power consumption
104 * Monitor soil pH with temperature compensation.
105 * Monitor soil temperature
106 * Monitor Battery Level
107 * Support pH calibration by end user
108 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
109 * AT Commands to change parameters
110 * Uplink on periodically
111 * Downlink to change configure
112 * IP66 Waterproof Enclosure
113 * IP68 rate for the Sensor Probe
114 * 8500mAh Battery for long term use
115
116
117 == 1.3 Probe Specification ==
118
119
120 (% style="color:#4f81bd" %)**Soil pH:**
121
122 * Range: 3 ~~ 10 pH
123 * Resolution: 0.01 pH
124 * Accuracy: ±2% under (0~~50 ℃, Accuracy will poor under 0 due to frozen)
125 * Temperature Compensation Range: 0 ~~ 50℃
126 * IP68 Protection
127 * Length: 3.5 meters
128
129 (% style="color:#4f81bd" %)**Soil Temperature:**
130
131 * Range -40℃~85℃
132 * Resolution: 0.1℃
133 * Accuracy: <±0.5℃(-10℃~40℃),<±0.8℃ (others)
134 * IP68 Protection
135 * Length: 3.5 meters
136
137
138 == 1.4 ​Applications ==
139
140 * Smart Agriculture
141
142
143 == 1.5 Pin mapping and power on ==
144
145 [[image:1654592472094-134.png]]
146
147
148
149 = 2. Configure LSPH01 to connect to LoRaWAN network =
150
151 == 2.1 How it works ==
152
153 (((
154 The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
155 )))
156
157 (((
158 In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
159 )))
160
161
162 == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
163
164 (((
165 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
166 )))
167
168 (((
169 [[image:1654592492399-921.png]]
170
171
172 )))
173
174 (((
175 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
176
177
178 )))
179
180 (((
181 (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LSPH01.
182 )))
183
184 (((
185 Each LSPH01 is shipped with a sticker with the default device EUI as below:
186 )))
187
188 [[image:image-20220607170145-1.jpeg]]
189
190
191
192 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
193
194
195 **Register the device**
196
197
198 [[image:1654592600093-601.png]]
199
200
201
202 **Add APP EUI and DEV EUI**
203
204 [[image:1654592619856-881.png]]
205
206
207
208 **Add APP EUI in the application**
209
210 [[image:1654592632656-512.png]]
211
212
213
214 **Add APP KEY**
215
216 [[image:1654592653453-934.png]]
217
218
219 (% style="color:blue" %)**Step 2**(%%): Power on LSPH01
220
221
222 Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position).
223
224 [[image:image-20220607170442-2.png]]
225
226
227 (((
228 (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
229 )))
230
231 [[image:1654592697690-910.png]]
232
233
234
235 == 2.3 ​Uplink Payload ==
236
237 (((
238 LSPH01 will uplink payload via LoRaWAN with below payload format: 
239 )))
240
241 (((
242 Uplink payload includes in total 11 bytes.
243 )))
244
245 (((
246 Normal uplink payload:
247 )))
248
249 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
250 |=(% style="width: 62.5px;" %)(((
251 **Size (bytes)**
252 )))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
253 |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
254 [[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
255
256 [[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
257 )))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
258 [[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
259 )))|Reserve|(((
260 [[Message Type>>||anchor="H2.3.6MessageType"]]
261 )))
262
263 [[image:1654592721645-318.png]]
264
265
266
267 === 2.3.1 Battery Info ===
268
269
270 Check the battery voltage for LSPH01.
271
272 Ex1: 0x0B45 = 2885mV
273
274 Ex2: 0x0B49 = 2889mV
275
276
277
278 === 2.3.2 DS18B20 Temperature sensor ===
279
280 This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
281
282
283 **Example**:
284
285 If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
286
287 If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
288
289
290
291 === 2.3.3 Soil pH ===
292
293 Range: 0 ~~ 14 pH
294
295 **Example:**
296
297 (% style="color:#037691" %)** 0x02B7(H) = 695(D) = 6.95pH**
298
299
300
301 === 2.3.4 Soil Temperature ===
302
303 Get Soil Temperature 
304
305
306 **Example**:
307
308 If payload is: **0105H**:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
309
310 If payload is: **FF3FH** :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
311
312
313
314 === 2.3.5 Interrupt Pin ===
315
316 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
317
318
319 **Example:**
320
321 0x00: Normal uplink packet.
322
323 0x01: Interrupt Uplink Packet.
324
325
326
327 === 2.3.6 Message Type ===
328
329 (((
330 For a normal uplink payload, the message type is always 0x01.
331 )))
332
333 (((
334 Valid Message Type:
335 )))
336
337
338 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
339 |=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
340 |(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
341 |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
342 |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
343
344
345 === 2.3.7 Decode payload in The Things Network ===
346
347 While using TTN network, you can add the payload format to decode the payload.
348
349
350 [[image:1654592762713-715.png]]
351
352 (((
353 The payload decoder function for TTN is here:
354 )))
355
356 (((
357 LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
358 )))
359
360
361
362 == 2.4 Uplink Interval ==
363
364 The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
365
366
367
368 == 2.5 ​Show Data in DataCake IoT Server ==
369
370 (((
371 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
372 )))
373
374 (((
375
376 )))
377
378 (((
379 (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
380 )))
381
382 (((
383 (% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
384 )))
385
386
387 [[image:1654592790040-760.png]]
388
389
390 [[image:1654592800389-571.png]]
391
392
393 (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
394
395 (% style="color:blue" %)**Step 4**(%%)**: Create LSPH01 product.**
396
397 [[image:1654592819047-535.png]]
398
399
400
401 [[image:1654592833877-762.png]]
402
403
404 [[image:1654592856403-259.png]]
405
406
407 (((
408 (% style="color:blue" %)**Step 5**(%%)**: add payload decode**
409 )))
410
411 (((
412 Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
413 )))
414
415
416 [[image:1654592878525-845.png]]
417
418 [[image:1654592892967-474.png]]
419
420
421 [[image:1654592905354-123.png]]
422
423
424 After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
425
426
427 [[image:1654592917530-261.png]]
428
429
430
431 == 2.6 Installation and Maintain ==
432
433 === 2.6.1 Before measurement ===
434
435 (((
436 (((
437 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
438 )))
439 )))
440
441
442
443 === 2.6.2 Measurement ===
444
445
446 (((
447 (% style="color:#4f81bd" %)**Measurement the soil surface:**
448 )))
449
450 (((
451 [[image:1654592946732-634.png]]
452 )))
453
454 (((
455 Choose the proper measuring position. Split the surface soil according to the measured deep.
456 )))
457
458 (((
459 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things.
460 )))
461
462 (((
463 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting.
464 )))
465
466 (((
467 Put soil over the probe after insert. And start to measure.
468 )))
469
470 (((
471
472 )))
473
474 (((
475 (% style="color:#4f81bd" %)**Measurement inside soil:**
476 )))
477
478 (((
479 Dig a hole with diameter > 20CM.
480 )))
481
482 (((
483 Insert the probe inside, method like measure the surface.
484 )))
485
486
487
488 === 2.6.3 Maintain Probe ===
489
490 1. (((
491 pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
492 )))
493 1. (((
494 After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
495 )))
496 1. (((
497 Probe reference electrode is also no strong, need to avoid strong force or hitting.
498 )))
499 1. (((
500 User should keep reference electrode wet while not use.
501 )))
502 1. (((
503 Avoid the probes to touch oily matter. Which will cause issue in accuracy.
504 )))
505 1. (((
506 The probe is IP68 can be put in water.
507
508
509
510 )))
511
512 == 2.7 Calibration ==
513
514 (((
515 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
516 )))
517
518 (((
519 After stable, user can use below command to calibrate.
520 )))
521
522 [[image:image-20220607171149-4.png]]
523
524
525 (% style="color:#037691" %)**Calibration Payload**
526
527 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
528 |=(% style="width: 62.5px;" %)(((
529 **Size (bytes)**
530 )))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
531 |**Value**|(((
532 PH4
533
534 Calibrate value
535 )))|PH6.86 Calibrate value|(((
536 PH9.18
537
538 Calibrate value
539 )))|Reserve|(((
540 [[Message Type>>||anchor="H2.3.6MessageType"]]
541
542 Always 0x03
543 )))
544
545 User can also send 0x14 downlink command to poll the current calibration payload.
546
547 [[image:image-20220607171416-7.jpeg]]
548
549
550 * Reply to the confirmation package: 14 01
551 * Reply to non-confirmed packet: 14 00
552
553
554
555
556
557
558 == 2.8 Frequency Plans ==
559
560 (((
561 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
562 )))
563
564
565 === 2.8.1 EU863-870 (EU868) ===
566
567 (((
568 (% style="color:blue" %)**Uplink:**
569 )))
570
571 (((
572 868.1 - SF7BW125 to SF12BW125
573 )))
574
575 (((
576 868.3 - SF7BW125 to SF12BW125 and SF7BW250
577 )))
578
579 (((
580 868.5 - SF7BW125 to SF12BW125
581 )))
582
583 (((
584 867.1 - SF7BW125 to SF12BW125
585 )))
586
587 (((
588 867.3 - SF7BW125 to SF12BW125
589 )))
590
591 (((
592 867.5 - SF7BW125 to SF12BW125
593 )))
594
595 (((
596 867.7 - SF7BW125 to SF12BW125
597 )))
598
599 (((
600 867.9 - SF7BW125 to SF12BW125
601 )))
602
603 (((
604 868.8 - FSK
605 )))
606
607 (((
608
609 )))
610
611 (((
612 (% style="color:blue" %)**Downlink:**
613 )))
614
615 (((
616 Uplink channels 1-9 (RX1)
617 )))
618
619 (((
620 869.525 - SF9BW125 (RX2 downlink only)
621 )))
622
623
624
625 === 2.8.2 US902-928(US915) ===
626
627 (((
628 Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
629 )))
630
631 (((
632 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
633 )))
634
635 (((
636 After Join success, the end node will switch to the correct sub band by:
637 )))
638
639 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
640 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
641
642
643
644
645
646
647 === 2.8.3 CN470-510 (CN470) ===
648
649 (((
650 Used in China, Default use CHE=1
651 )))
652
653 (((
654 (% style="color:blue" %)**Uplink:**
655 )))
656
657 (((
658 486.3 - SF7BW125 to SF12BW125
659 )))
660
661 (((
662 486.5 - SF7BW125 to SF12BW125
663 )))
664
665 (((
666 486.7 - SF7BW125 to SF12BW125
667 )))
668
669 (((
670 486.9 - SF7BW125 to SF12BW125
671 )))
672
673 (((
674 487.1 - SF7BW125 to SF12BW125
675 )))
676
677 (((
678 487.3 - SF7BW125 to SF12BW125
679 )))
680
681 (((
682 487.5 - SF7BW125 to SF12BW125
683 )))
684
685 (((
686 487.7 - SF7BW125 to SF12BW125
687 )))
688
689 (((
690
691 )))
692
693 (((
694 (% style="color:blue" %)**Downlink:**
695 )))
696
697 (((
698 506.7 - SF7BW125 to SF12BW125
699 )))
700
701 (((
702 506.9 - SF7BW125 to SF12BW125
703 )))
704
705 (((
706 507.1 - SF7BW125 to SF12BW125
707 )))
708
709 (((
710 507.3 - SF7BW125 to SF12BW125
711 )))
712
713 (((
714 507.5 - SF7BW125 to SF12BW125
715 )))
716
717 (((
718 507.7 - SF7BW125 to SF12BW125
719 )))
720
721 (((
722 507.9 - SF7BW125 to SF12BW125
723 )))
724
725 (((
726 508.1 - SF7BW125 to SF12BW125
727 )))
728
729 (((
730 505.3 - SF12BW125 (RX2 downlink only)
731 )))
732
733
734
735 === 2.8.4 AU915-928(AU915) ===
736
737 (((
738 Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
739 )))
740
741 (((
742 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
743 )))
744
745 (((
746
747 )))
748
749 (((
750 After Join success, the end node will switch to the correct sub band by:
751 )))
752
753 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
754 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
755
756
757 === 2.8.5 AS920-923 & AS923-925 (AS923) ===
758
759 (((
760 (% style="color:blue" %)**Default Uplink channel:**
761 )))
762
763 (((
764 923.2 - SF7BW125 to SF10BW125
765 )))
766
767 (((
768 923.4 - SF7BW125 to SF10BW125
769 )))
770
771 (((
772
773 )))
774
775 (((
776 (% style="color:blue" %)**Additional Uplink Channel**:
777 )))
778
779 (((
780 (OTAA mode, channel added by JoinAccept message)
781 )))
782
783 (((
784
785 )))
786
787 (((
788 (% style="color:blue" %)**AS920~~AS923 for Japan, Malaysia, Singapore**:
789 )))
790
791 (((
792 922.2 - SF7BW125 to SF10BW125
793 )))
794
795 (((
796 922.4 - SF7BW125 to SF10BW125
797 )))
798
799 (((
800 922.6 - SF7BW125 to SF10BW125
801 )))
802
803 (((
804 922.8 - SF7BW125 to SF10BW125
805 )))
806
807 (((
808 923.0 - SF7BW125 to SF10BW125
809 )))
810
811 (((
812 922.0 - SF7BW125 to SF10BW125
813 )))
814
815 (((
816
817 )))
818
819 (((
820 (% style="color:blue" %)**AS923 ~~ AS925 for Brunei, Cambodia, Hong Kong, Indonesia, Laos, Taiwan, Thailand, Vietnam**:
821 )))
822
823 (((
824 923.6 - SF7BW125 to SF10BW125
825 )))
826
827 (((
828 923.8 - SF7BW125 to SF10BW125
829 )))
830
831 (((
832 924.0 - SF7BW125 to SF10BW125
833 )))
834
835 (((
836 924.2 - SF7BW125 to SF10BW125
837 )))
838
839 (((
840 924.4 - SF7BW125 to SF10BW125
841 )))
842
843 (((
844 924.6 - SF7BW125 to SF10BW125
845 )))
846
847 (((
848
849 )))
850
851 (((
852 (% style="color:blue" %)**Downlink:**
853 )))
854
855 (((
856 Uplink channels 1-8 (RX1)
857 )))
858
859 (((
860 923.2 - SF10BW125 (RX2)
861 )))
862
863
864
865 === 2.8.6 KR920-923 (KR920) ===
866
867 (((
868 (% style="color:blue" %)**Default channel:**
869 )))
870
871 (((
872 922.1 - SF7BW125 to SF12BW125
873 )))
874
875 (((
876 922.3 - SF7BW125 to SF12BW125
877 )))
878
879 (((
880 922.5 - SF7BW125 to SF12BW125
881 )))
882
883 (((
884
885 )))
886
887 (((
888 (% style="color:blue" %)**Uplink: (OTAA mode, channel added by JoinAccept message)**
889 )))
890
891 (((
892 922.1 - SF7BW125 to SF12BW125
893 )))
894
895 (((
896 922.3 - SF7BW125 to SF12BW125
897 )))
898
899 (((
900 922.5 - SF7BW125 to SF12BW125
901 )))
902
903 (((
904 922.7 - SF7BW125 to SF12BW125
905 )))
906
907 (((
908 922.9 - SF7BW125 to SF12BW125
909 )))
910
911 (((
912 923.1 - SF7BW125 to SF12BW125
913 )))
914
915 (((
916 923.3 - SF7BW125 to SF12BW125
917 )))
918
919 (((
920
921 )))
922
923 (((
924 (% style="color:blue" %)**Downlink:**
925 )))
926
927 (((
928 Uplink channels 1-7(RX1)
929 )))
930
931 (((
932 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
933 )))
934
935
936
937 === 2.8.7 IN865-867 (IN865) ===
938
939 (((
940 (% style="color:blue" %)**Uplink:**
941 )))
942
943 (((
944 865.0625 - SF7BW125 to SF12BW125
945 )))
946
947 (((
948 865.4025 - SF7BW125 to SF12BW125
949 )))
950
951 (((
952 865.9850 - SF7BW125 to SF12BW125
953 )))
954
955 (((
956
957 )))
958
959 (((
960 (% style="color:blue" %)**Downlink:**
961 )))
962
963 (((
964 Uplink channels 1-3 (RX1)
965 )))
966
967 (((
968 866.550 - SF10BW125 (RX2)
969 )))
970
971
972
973 == 2.9 LED Indicator ==
974
975 The LSPH01 has an internal LED which is to show the status of different state.
976
977 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
978 * Blink once when device transmit a packet.
979
980
981 == 2.10 ​Firmware Change Log ==
982
983
984 **Firmware download link:**
985
986 [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
987
988
989 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
990
991
992
993 = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
994
995 (((
996 Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
997 )))
998
999 * (((
1000 AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
1001 )))
1002 * (((
1003 LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
1004 )))
1005
1006 (((
1007 There are two kinds of commands to configure LSPH01, they are:
1008 )))
1009
1010 * (((
1011 (% style="color:#4f81bd" %)** General Commands**.
1012 )))
1013
1014 (((
1015 These commands are to configure:
1016 )))
1017
1018 * (((
1019 General system settings like: uplink interval.
1020 )))
1021 * (((
1022 LoRaWAN protocol & radio related command.
1023 )))
1024
1025 (((
1026 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1027 )))
1028
1029 (((
1030
1031 )))
1032
1033 * (((
1034 (% style="color:#4f81bd" %)** Commands special design for LSPH01**
1035 )))
1036
1037 (((
1038 These commands only valid for LSPH01, as below:
1039 )))
1040
1041
1042
1043 == 3.1 Set Transmit Interval Time ==
1044
1045 Feature: Change LoRaWAN End Node Transmit Interval.
1046
1047 (% style="color:#037691" %)**AT Command: AT+TDC**
1048
1049 [[image:image-20220607171554-8.png]]
1050
1051
1052 (((
1053 (% style="color:#037691" %)**Downlink Command: 0x01**
1054 )))
1055
1056 (((
1057 Format: Command Code (0x01) followed by 3 bytes time value.
1058 )))
1059
1060 (((
1061 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1062 )))
1063
1064 * (((
1065 Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1066 )))
1067 * (((
1068 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1069
1070
1071
1072 )))
1073
1074 == 3.2 Set Interrupt Mode ==
1075
1076 Feature, Set Interrupt mode for GPIO_EXIT.
1077
1078 (% style="color:#037691" %)**AT Command: AT+INTMOD**
1079
1080 [[image:image-20220610105907-1.png]]
1081
1082
1083 (((
1084 (% style="color:#037691" %)**Downlink Command: 0x06**
1085 )))
1086
1087 (((
1088 Format: Command Code (0x06) followed by 3 bytes.
1089 )))
1090
1091 (((
1092 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1093 )))
1094
1095 * (((
1096 Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1097 )))
1098 * (((
1099 Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1100 )))
1101
1102 (((
1103
1104 )))
1105
1106
1107
1108 == 3.3 Calibrate Sensor ==
1109
1110 Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1111
1112
1113
1114 == 3.4 Get Firmware Version Info ==
1115
1116 Feature: use downlink to get firmware version.
1117
1118 (% style="color:#037691" %)**Downlink Command: 0x26**
1119
1120 [[image:image-20220607171917-10.png]]
1121
1122 * Reply to the confirmation package: 26 01
1123 * Reply to non-confirmed packet: 26 00
1124
1125 Device will send an uplink after got this downlink command. With below payload:
1126
1127 Configures info payload:
1128
1129 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
1130 |=(((
1131 **Size(bytes)**
1132 )))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
1133 |**Value**|Software Type|(((
1134 Frequency
1135
1136 Band
1137 )))|Sub-band|(((
1138 Firmware
1139
1140 Version
1141 )))|Sensor Type|Reserve|(((
1142 [[Message Type>>||anchor="H2.3.6MessageType"]]
1143 Always 0x02
1144 )))
1145
1146 **Software Type**: Always 0x03 for LSPH01
1147
1148
1149 **Frequency Band**:
1150
1151 *0x01: EU868
1152
1153 *0x02: US915
1154
1155 *0x03: IN865
1156
1157 *0x04: AU915
1158
1159 *0x05: KZ865
1160
1161 *0x06: RU864
1162
1163 *0x07: AS923
1164
1165 *0x08: AS923-1
1166
1167 *0x09: AS923-2
1168
1169 *0xa0: AS923-3
1170
1171
1172 **Sub-Band**: value 0x00 ~~ 0x08
1173
1174
1175 **Firmware Version**: 0x0100, Means: v1.0.0 version
1176
1177
1178 **Sensor Type**:
1179
1180 0x01: LSE01
1181
1182 0x02: LDDS75
1183
1184 0x03: LDDS20
1185
1186 0x04: LLMS01
1187
1188 0x05: LSPH01
1189
1190 0x06: LSNPK01
1191
1192 0x07: LDDS12
1193
1194
1195
1196 = 4. Battery & How to replace =
1197
1198 == 4.1 Battery Type ==
1199
1200 (((
1201 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1202 )))
1203
1204 (((
1205 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1206 )))
1207
1208 [[image:1654593587246-335.png]]
1209
1210
1211 Minimum Working Voltage for the LSPH01:
1212
1213 LSPH01:  2.45v ~~ 3.6v
1214
1215
1216
1217 == 4.2 Replace Battery ==
1218
1219 (((
1220 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1221 )))
1222
1223 (((
1224 And make sure the positive and negative pins match.
1225 )))
1226
1227
1228
1229 == 4.3 Power Consumption Analyze ==
1230
1231 (((
1232 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1233 )))
1234
1235 (((
1236 Instruction to use as below:
1237 )))
1238
1239
1240 **Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1241
1242 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1243
1244
1245 **Step 2**: Open it and choose
1246
1247 * Product Model
1248 * Uplink Interval
1249 * Working Mode
1250
1251 And the Life expectation in difference case will be shown on the right.
1252
1253 [[image:1654593605679-189.png]]
1254
1255
1256 The battery related documents as below:
1257
1258 * (((
1259 [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1260 )))
1261 * (((
1262 [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1263 )))
1264 * (((
1265 [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1266 )))
1267
1268 [[image:image-20220607172042-11.png]]
1269
1270
1271
1272 === 4.3.1 ​Battery Note ===
1273
1274 (((
1275 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1276 )))
1277
1278
1279
1280 === ​4.3.2 Replace the battery ===
1281
1282 (((
1283 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1284 )))
1285
1286 (((
1287 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1288 )))
1289
1290
1291
1292 = 5. Use AT Command =
1293
1294 == 5.1 Access AT Commands ==
1295
1296 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1297
1298 [[image:1654593668970-604.png]]
1299
1300 **Connection:**
1301
1302 (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
1303
1304 (% style="background-color:yellow" %)** USB TTL TXD  <~-~-~-~-> UART_RXD**
1305
1306 (% style="background-color:yellow" %)** USB TTL RXD  <~-~-~-~-> UART_TXD**
1307
1308
1309 (((
1310 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
1311 )))
1312
1313
1314 [[image:1654593712276-618.png]]
1315
1316 Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].
1317
1318
1319 = 6. FAQ =
1320
1321 == 6.1 How to change the LoRa Frequency Bands/Region ==
1322
1323 You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1324 When downloading the images, choose the required image file for download. ​
1325
1326
1327 = 7. Trouble Shooting =
1328
1329 == 7.1 AT Commands input doesn’t work ==
1330
1331 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1332
1333
1334
1335 = 8. Order Info =
1336
1337 Part Number: (% style="color:blue" %)**LSPH01-XX**
1338
1339
1340 (% style="color:blue" %)**XX**(%%): The default frequency band
1341
1342 * (% style="color:red" %)**AS923**(%%):  LoRaWAN AS923 band
1343 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
1344 * (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
1345 * (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
1346 * (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
1347 * (% style="color:red" %)**US915**(%%): LoRaWAN US915 band
1348 * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1349 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1350
1351 = 9. ​Packing Info =
1352
1353
1354 **Package Includes**:
1355
1356 * LSPH01 LoRaWAN Soil Ph Sensor x 1
1357
1358 **Dimension and weight**:
1359
1360 * Device Size: cm
1361 * Device Weight: g
1362 * Package Size / pcs : cm
1363 * Weight / pcs : g
1364
1365 = 10. ​Support =
1366
1367 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1368 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
1369
1370
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0