<
From version < 26.8 >
edited by Xiaoling
on 2022/06/07 15:08
To version < 26.9 >
edited by Xiaoling
on 2022/06/07 15:11
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -427,6 +427,8 @@
427 427  Always 0x03
428 428  )))
429 429  
430 +
431 +
430 430  User can also send 0x14 downlink command to poll the current calibration payload.
431 431  
432 432  [[image:image-20220607145603-4.png]]
... ... @@ -489,7 +489,6 @@
489 489  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
490 490  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
491 491  
492 -
493 493  === 2.8.3 CN470-510 (CN470) ===
494 494  
495 495  Used in China, Default use CHE=1
... ... @@ -556,7 +556,6 @@
556 556  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
557 557  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
558 558  
559 -
560 560  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
561 561  
562 562  (% style="color:blue" %)**Default Uplink channel:**
... ... @@ -670,15 +670,14 @@
670 670  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
671 671  * Blink once when device transmit a packet.
672 672  
673 +== 2.10 ​Firmware Change Log ==
673 673  
674 -1. ​Firmware Change Log
675 -
676 676  **Firmware download link:**
677 677  
678 678  [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
679 679  
680 680  
681 -**Firmware Upgrade Method:**
680 +**Firmware Upgrade Method:[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]**
682 682  
683 683  [[http:~~/~~/wiki.dragino.com/index.pHp?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Introduction>>url:http://wiki.dragino.com/index.php?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Introduction]]
684 684  
... ... @@ -716,7 +716,7 @@
716 716  These commands only valid for LSPH01, as below:
717 717  
718 718  
719 -1.
718 +1.
720 720  11. Set Transmit Interval Time
721 721  
722 722  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -746,7 +746,7 @@
746 746  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
747 747  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
748 748  
749 -1.
748 +1.
750 750  11. Set Interrupt Mode
751 751  
752 752  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -779,7 +779,7 @@
779 779  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
780 780  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
781 781  
782 -1.
781 +1.
783 783  11. Calibrate Sensor
784 784  
785 785  Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -786,7 +786,7 @@
786 786  
787 787  
788 788  
789 -1.
788 +1.
790 790  11. Get Firmware Version Info
791 791  
792 792  Feature: use downlink to get firmware version.
... ... @@ -895,7 +895,7 @@
895 895  LSPH01:  2.45v ~~ 3.6v
896 896  
897 897  
898 -1.
897 +1.
899 899  11. Replace Battery
900 900  
901 901  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
... ... @@ -904,7 +904,7 @@
904 904  
905 905  
906 906  
907 -1.
906 +1.
908 908  11. Power Consumption Analyze
909 909  
910 910  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
... ... @@ -944,14 +944,14 @@
944 944  
945 945  
946 946  1.
947 -11.
946 +11.
948 948  111. ​Battery Note
949 949  
950 950  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
951 951  
952 952  
953 -1.
954 -11.
952 +1.
953 +11.
955 955  111. ​Replace the battery
956 956  
957 957  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0