From version < 26.3 >
edited by Xiaoling
on 2022/06/07 14:58
To version < 26.1 >
edited by Xiaoling
on 2022/06/07 14:56
>
Change comment: Uploaded new attachment "image-20220607145603-4.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -265,8 +265,6 @@
265 265  |0x02|Reply configures info|[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
266 266  |0x03|Reply Calibration Info|[[Calibration Payload>>||anchor="H2.7Calibration"]]
267 267  
268 -
269 -
270 270  === 2.3.7 Decode payload in The Things Network ===
271 271  
272 272  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -402,11 +402,13 @@
402 402  
403 403  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
404 404  
405 -After stable, user can use below command to calibrate.
406 406  
404 +(% style="color:#037691" %)**After stable, user can use below command to calibrate.**
405 +
407 407  [[image:image-20220607144936-3.png]]
408 408  
409 409  
409 +
410 410  (% style="color:#037691" %)**Calibration Payload**
411 411  
412 412  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
... ... @@ -431,19 +431,20 @@
431 431  
432 432  User can also send 0x14 downlink command to poll the current calibration payload.
433 433  
434 -[[image:image-20220607145603-4.png]]
435 435  
435 +|**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)**
436 +|Get Calibration Version Info|Any|14|2
437 +
436 436  * Reply to the confirmation package: 14 01
437 437  * Reply to non-confirmed packet: 14 00
438 438  
441 +1.
442 +11. Frequency Plans
439 439  
440 -
441 -Frequency Plans
442 -
443 443  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
444 444  
445 -1.
446 -11.
446 +1.
447 +11.
447 447  111. EU863-870 (EU868)
448 448  
449 449  Uplink:
... ... @@ -474,8 +474,8 @@
474 474  869.525 - SF9BW125 (RX2 downlink only)
475 475  
476 476  
477 -1.
478 -11.
478 +1.
479 +11.
479 479  111. US902-928(US915)
480 480  
481 481  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
... ... @@ -489,8 +489,8 @@
489 489  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
490 490  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
491 491  
492 -1.
493 -11.
493 +1.
494 +11.
494 494  111. CN470-510 (CN470)
495 495  
496 496  Used in China, Default use CHE=1
... ... @@ -535,8 +535,8 @@
535 535  505.3 - SF12BW125 (RX2 downlink only)
536 536  
537 537  
538 -1.
539 -11.
539 +1.
540 +11.
540 540  111. AU915-928(AU915)
541 541  
542 542  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
... ... @@ -550,8 +550,8 @@
550 550  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
551 551  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
552 552  
553 -1.
554 -11.
554 +1.
555 +11.
555 555  111. AS920-923 & AS923-925 (AS923)
556 556  
557 557  **Default Uplink channel:**
... ... @@ -603,8 +603,8 @@
603 603  923.2 - SF10BW125 (RX2)
604 604  
605 605  
606 -1.
607 -11.
607 +1.
608 +11.
608 608  111. KR920-923 (KR920)
609 609  
610 610  Default channel:
... ... @@ -640,8 +640,8 @@
640 640  921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
641 641  
642 642  
643 -1.
644 -11.
644 +1.
645 +11.
645 645  111. IN865-867 (IN865)
646 646  
647 647  Uplink:
... ... @@ -660,7 +660,7 @@
660 660  866.550 - SF10BW125 (RX2)
661 661  
662 662  
663 -1.
664 +1.
664 664  11. LED Indicator
665 665  
666 666  The LSPH01 has an internal LED which is to show the status of different state.
... ... @@ -669,7 +669,7 @@
669 669  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
670 670  * Blink once when device transmit a packet.
671 671  
672 -1.
673 +1.
673 673  11. ​Firmware Change Log
674 674  
675 675  **Firmware download link:**
... ... @@ -715,7 +715,7 @@
715 715  These commands only valid for LSPH01, as below:
716 716  
717 717  
718 -1.
719 +1.
719 719  11. Set Transmit Interval Time
720 720  
721 721  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -745,7 +745,7 @@
745 745  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
746 746  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
747 747  
748 -1.
749 +1.
749 749  11. Set Interrupt Mode
750 750  
751 751  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -778,7 +778,7 @@
778 778  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
779 779  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
780 780  
781 -1.
782 +1.
782 782  11. Calibrate Sensor
783 783  
784 784  Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -785,7 +785,7 @@
785 785  
786 786  
787 787  
788 -1.
789 +1.
789 789  11. Get Firmware Version Info
790 790  
791 791  Feature: use downlink to get firmware version.
... ... @@ -894,7 +894,7 @@
894 894  LSPH01:  2.45v ~~ 3.6v
895 895  
896 896  
897 -1.
898 +1.
898 898  11. Replace Battery
899 899  
900 900  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
... ... @@ -903,7 +903,7 @@
903 903  
904 904  
905 905  
906 -1.
907 +1.
907 907  11. Power Consumption Analyze
908 908  
909 909  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
... ... @@ -943,14 +943,14 @@
943 943  
944 944  
945 945  1.
946 -11.
947 +11.
947 947  111. ​Battery Note
948 948  
949 949  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
950 950  
951 951  
952 -1.
953 -11.
953 +1.
954 +11.
954 954  111. ​Replace the battery
955 955  
956 956  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0