432 432  User can also send 0x14 downlink command to poll the current calibration payload.
433 433  
434 434  [[image:image-20220607145603-4.png]]
... ... @@ -437,7 +437,6 @@
437 437  * Reply to non-confirmed packet: 14 00
438 438  
439 439  
440 -
441 441  == 2.8 Frequency Plans ==
442 442  
443 443  (((
... ... @@ -494,7 +494,6 @@
494 494  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
495 495  
496 496  
497 -
498 498  === 2.8.3 CN470-510 (CN470) ===
499 499  
500 500  Used in China, Default use CHE=1
... ... @@ -562,7 +562,6 @@
562 562  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
563 563  
564 564  
565 -
566 566  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
567 567  
568 568  (% style="color:blue" %)**Default Uplink channel:**
... ... @@ -677,7 +677,6 @@
677 677  * Blink once when device transmit a packet.
678 678  
679 679  
680 -
681 681  == 2.10 ​Firmware Change Log ==
682 682  
683 683  
... ... @@ -694,15 +694,13 @@
694 694  
695 695  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
696 696  
697 -* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
698 -* LoRaWAN Downlink instruction for different platforms:
692 +* AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
693 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
699 699  
700 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]]
701 701  
702 -
703 703  There are two kinds of commands to configure LSPH01, they are:
704 704  
705 -* **General Commands**.
698 +* **(% style="color:#4F81BD" %) General Commands**.
706 706  
707 707  These commands are to configure:
708 708  
... ... @@ -709,17 +709,15 @@
709 709  * General system settings like: uplink interval.
710 710  * LoRaWAN protocol & radio related command.
711 711  
712 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
705 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
713 713  
714 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
715 715  
708 +* **(% style="color:#4F81BD" %) Commands special design for LSPH01**
716 716  
717 -* **Commands special design for LSPH01**
718 -
719 719  These commands only valid for LSPH01, as below:
720 720  
721 721  
722 -1.
713 +1.
723 723  11. Set Transmit Interval Time
724 724  
725 725  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -749,7 +749,7 @@
749 749  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
750 750  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
751 751  
752 -1.
743 +1.
753 753  11. Set Interrupt Mode
754 754  
755 755  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -782,7 +782,7 @@
782 782  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
783 783  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
784 784  
785 -1.
776 +1.
786 786  11. Calibrate Sensor
787 787  
788 788  Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -789,7 +789,7 @@
789 789  
790 790  
791 791  
792 -1.
783 +1.
793 793  11. Get Firmware Version Info
794 794  
795 795  Feature: use downlink to get firmware version.
... ... @@ -898,7 +898,7 @@
898 898  LSPH01:  2.45v ~~ 3.6v
899 899  
900 900  
901 -1.
892 +1.
902 902  11. Replace Battery
903 903  
904 904  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
... ... @@ -907,7 +907,7 @@
907 907  
908 908  
909 909  
910 -1.
901 +1.
911 911  11. Power Consumption Analyze
912 912  
913 913  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
... ... @@ -947,14 +947,14 @@
947 947  
948 948  
949 949  1.
950 -11.
941 +11.
951 951  111. ​Battery Note
952 952  
953 953  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
954 954  
955 955  
956 -1.
957 -11.
947 +1.
948 +11.
958 958  111. ​Replace the battery
959 959  
960 960  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.