From version < 25.2 >
edited by Xiaoling
on 2022/06/07 14:54
To version < 25.1 >
edited by Xiaoling
on 2022/06/07 14:49
>
Change comment: Uploaded new attachment "image-20220607144936-3.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -338,6 +338,8 @@
338 338  
339 339  
340 340  
341 +
342 +
341 341  == 2.6 Installation and Maintain ==
342 342  
343 343  === 2.6.1 Before measurement ===
... ... @@ -391,10 +391,9 @@
391 391  )))
392 392  1. (((
393 393  The probe is IP68 can be put in water.
396 +)))
394 394  
395 395  
396 -
397 -)))
398 398  
399 399  == 2.7 Calibration ==
400 400  
... ... @@ -401,15 +401,41 @@
401 401  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
402 402  
403 403  
404 -(% style="color:#037691" %)**After stable, user can use below command to calibrate.**
405 +**After stable, user can use below command to calibrate.**
405 405  
406 -[[image:image-20220607144936-3.png]]
407 407  
408 +|**pH buffer solution**|**AT Command to calibrate**|**Downlink Command**|**Read Cal Value**
409 +|**4.00**|**AT+PHCAL=4**|(((
410 +**0x13 04**
408 408  
412 +**Reply with Calibrate payload**
413 +)))|(((
414 +**AT+PHCAL=?**
409 409  
410 -(% style="color:#037691" %)**Calibration Payload**
416 +**Example 41,61,91**
417 +)))
418 +|**6.86**|**AT+PHCAL=6**|(((
419 +**0x13 06**
411 411  
412 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
421 +**Reply with Calibrate payload**
422 +)))|**AT+PHCAL=?**
423 +|**9.18**|**AT+PHCAL=9**|(((
424 +**0x13 09**
425 +
426 +**Reply with Calibrate payload**
427 +)))|**AT+PHCAL=?**
428 +|**Factory Default**|**AT+PHCAL=15**|(((
429 +**0x13 15**
430 +
431 +**Reply with Calibrate payload**
432 +)))|(((
433 +**AT+PHCAL=?**
434 +
435 +**Example 151**
436 +)))
437 +
438 +Calibration Payload
439 +
413 413  |(((
414 414  **Size**
415 415  
... ... @@ -424,7 +424,11 @@
424 424  
425 425  Calibrate value
426 426  )))|Reserve|(((
427 -[[Message Type Always 0x03>>||anchor="H2.3.6MessageType"]]
454 +[[Message>>path:#Message_Type]]
455 +
456 +[[Type>>path:#Message_Type]]
457 +
458 +Always 0x03
428 428  )))
429 429  
430 430  User can also send 0x14 downlink command to poll the current calibration payload.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0