From version < 14.6 >
edited by Xiaoling
on 2022/06/07 14:28
To version < 14.3 >
edited by Xiaoling
on 2022/06/07 14:16
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -173,14 +173,18 @@
173 173  
174 174  **(bytes)**
175 175  )))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
176 -|**Value**|[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(((
177 -[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
176 +|**Value**|[[BAT>>path:#bat]]|(((
177 +[[Temperature>>path:#DS18B20]]
178 178  
179 -[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
180 -)))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
181 -[[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
179 +[[( Optional )>>path:#DS18B20]]
180 +)))|[[Soil pH>>path:#Soil_Nitrogen]]|[[Soil Temperature>>path:#Soil_Phosphorus]]|(((
181 +[[Digital Interrupt>>path:#Int_pin]]
182 +
183 +[[(Optional)>>path:#Int_pin]]
182 182  )))|Reserve|(((
183 -[[Message Type>>||anchor="H2.3.6MessageType"]]
185 +[[Message>>path:#Message_Type]]
186 +
187 +[[Type>>path:#Message_Type]]
184 184  )))
185 185  
186 186  [[image:1654581735133-458.png]]
... ... @@ -260,6 +260,8 @@
260 260  |0x02|Reply configures info|[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
261 261  |0x03|Reply Calibration Info|[[Calibration Payload>>||anchor="H2.7Calibration"]]
262 262  
267 +
268 +
263 263  === 2.3.7 Decode payload in The Things Network ===
264 264  
265 265  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -279,12 +279,13 @@
279 279  
280 280  == 2.4 Uplink Interval ==
281 281  
282 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
288 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
283 283  
290 +[[http:~~/~~/wiki.dragino.com/index.pHp?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]]
284 284  
285 285  
286 286  
287 -1.
294 +1.
288 288  11. ​Show Data in DataCake IoT Server
289 289  
290 290  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
... ... @@ -344,8 +344,8 @@
344 344  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
345 345  
346 346  
347 -1.
348 -11.
354 +1.
355 +11.
349 349  111. Measurement
350 350  
351 351  **Measurement the soil surface**
... ... @@ -373,8 +373,8 @@
373 373  Insert the probe inside, method like measure the surface.
374 374  
375 375  
376 -1.
377 -11.
383 +1.
384 +11.
378 378  111. Maintain Probe
379 379  1111. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
380 380  1111. After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
... ... @@ -383,7 +383,7 @@
383 383  1111. Avoid the probes to touch oily matter. Which will cause issue in accuracy.
384 384  1111. The probe is IP68 can be put in water.
385 385  
386 -1.
393 +1.
387 387  11. Calibration
388 388  
389 389  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
... ... @@ -454,13 +454,13 @@
454 454  * Reply to the confirmation package: 14 01
455 455  * Reply to non-confirmed packet: 14 00
456 456  
457 -1.
464 +1.
458 458  11. Frequency Plans
459 459  
460 460  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
461 461  
462 -1.
463 -11.
469 +1.
470 +11.
464 464  111. EU863-870 (EU868)
465 465  
466 466  Uplink:
... ... @@ -491,8 +491,8 @@
491 491  869.525 - SF9BW125 (RX2 downlink only)
492 492  
493 493  
494 -1.
495 -11.
501 +1.
502 +11.
496 496  111. US902-928(US915)
497 497  
498 498  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
... ... @@ -506,8 +506,8 @@
506 506  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
507 507  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
508 508  
509 -1.
510 -11.
516 +1.
517 +11.
511 511  111. CN470-510 (CN470)
512 512  
513 513  Used in China, Default use CHE=1
... ... @@ -552,8 +552,8 @@
552 552  505.3 - SF12BW125 (RX2 downlink only)
553 553  
554 554  
555 -1.
556 -11.
562 +1.
563 +11.
557 557  111. AU915-928(AU915)
558 558  
559 559  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
... ... @@ -567,8 +567,8 @@
567 567  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
568 568  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
569 569  
570 -1.
571 -11.
577 +1.
578 +11.
572 572  111. AS920-923 & AS923-925 (AS923)
573 573  
574 574  **Default Uplink channel:**
... ... @@ -620,8 +620,8 @@
620 620  923.2 - SF10BW125 (RX2)
621 621  
622 622  
623 -1.
624 -11.
630 +1.
631 +11.
625 625  111. KR920-923 (KR920)
626 626  
627 627  Default channel:
... ... @@ -657,8 +657,8 @@
657 657  921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
658 658  
659 659  
660 -1.
661 -11.
667 +1.
668 +11.
662 662  111. IN865-867 (IN865)
663 663  
664 664  Uplink:
... ... @@ -677,7 +677,7 @@
677 677  866.550 - SF10BW125 (RX2)
678 678  
679 679  
680 -1.
687 +1.
681 681  11. LED Indicator
682 682  
683 683  The LSPH01 has an internal LED which is to show the status of different state.
... ... @@ -686,7 +686,7 @@
686 686  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
687 687  * Blink once when device transmit a packet.
688 688  
689 -1.
696 +1.
690 690  11. ​Firmware Change Log
691 691  
692 692  **Firmware download link:**
... ... @@ -732,7 +732,7 @@
732 732  These commands only valid for LSPH01, as below:
733 733  
734 734  
735 -1.
742 +1.
736 736  11. Set Transmit Interval Time
737 737  
738 738  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -762,7 +762,7 @@
762 762  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
763 763  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
764 764  
765 -1.
772 +1.
766 766  11. Set Interrupt Mode
767 767  
768 768  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -795,7 +795,7 @@
795 795  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
796 796  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
797 797  
798 -1.
805 +1.
799 799  11. Calibrate Sensor
800 800  
801 801  Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -802,7 +802,7 @@
802 802  
803 803  
804 804  
805 -1.
812 +1.
806 806  11. Get Firmware Version Info
807 807  
808 808  Feature: use downlink to get firmware version.
... ... @@ -911,7 +911,7 @@
911 911  LSPH01:  2.45v ~~ 3.6v
912 912  
913 913  
914 -1.
921 +1.
915 915  11. Replace Battery
916 916  
917 917  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
... ... @@ -920,7 +920,7 @@
920 920  
921 921  
922 922  
923 -1.
930 +1.
924 924  11. Power Consumption Analyze
925 925  
926 926  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
... ... @@ -960,14 +960,14 @@
960 960  
961 961  
962 962  1.
963 -11.
970 +11.
964 964  111. ​Battery Note
965 965  
966 966  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
967 967  
968 968  
969 -1.
970 -11.
976 +1.
977 +11.
971 971  111. ​Replace the battery
972 972  
973 973  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0