From version < 54.1 >
edited by Edwin Chen
on 2022/12/26 11:20
To version < 54.2 >
edited by Xiaoling
on 2022/12/26 16:36
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -66,6 +66,8 @@
66 66  * Remote configure parameters via LoRa Downlink
67 67  * Firmware upgradable via program port
68 68  
69 +
70 +
69 69  == 1.3 Applications ==
70 70  
71 71  
... ... @@ -76,6 +76,8 @@
76 76  * Smart Cities
77 77  * Smart Factory
78 78  
81 +
82 +
79 79  == 1.4 Dimension ==
80 80  
81 81  
... ... @@ -87,8 +87,6 @@
87 87  [[image:1654680510816-654.png]]
88 88  
89 89  
90 -
91 -
92 92  == 1.5 Firmware Change log ==
93 93  
94 94  
... ... @@ -319,7 +319,6 @@
319 319  See [[Alarm Base Timeout>>||anchor="H4.6AlarmBaseonTimeout"]] for detail.
320 320  
321 321  
322 -
323 323  == 4.5 Integrate with Datacake ==
324 324  
325 325  
... ... @@ -468,6 +468,8 @@
468 468  |(% style="width:184px" %)Send an uplink message|(% style="width:275px" %)(% style="color:green" %)**GREEN LED**(%%) blinks once
469 469  |(% style="width:184px" %)Got a downlink message|(% style="width:275px" %)(% style="color:blue" %)**BLUE LED**(%%) blinks once
470 470  
472 +
473 +
471 471  = 5. Battery & How to replace =
472 472  
473 473  == 5.1 Battery Type and replace ==
... ... @@ -581,13 +581,15 @@
581 581  
582 582  == 7.4 How to change Sub-Band for LDS02? ==
583 583  
584 -* **Before v1.6 firmware**: LDS02 works in Subband 2 by default in AU915 / US915 band. So if the LoRaWAN server works in other subband, there will be issue for LWL02 to Join the server. In this case, User can use AT COmmand to change the subband. See AT Command chapther for the hardware connection. Below are the steps to change sub-band:
585 -** Press rest button.
586 -** Send **123456** password
587 -** Send command **AT+CFREQBANDMASK=0001 **( 0001 for subband 1, 0002 for subband 2, etc..)
588 -** Press rest button to restart to new subband
589 -** Example output:
590 590  
588 +(% style="color:blue" %)**Before v1.6 firmware**(%%): LDS02 works in Subband 2 by default in AU915 / US915 band. So if the LoRaWAN server works in other subband, there will be issue for LWL02 to Join the server. In this case, User can use AT COmmand to change the subband. See AT Command chapther for the hardware connection. Below are the steps to change sub-band:
589 +
590 +* Press rest button.
591 +* Send (% style="color:blue" %)**123456**(%%) password
592 +* Send command (% style="color:blue" %)**AT+CFREQBANDMASK=0001 **(%%)( 0001 for subband 1, 0002 for subband 2, etc..)
593 +* Press rest button to restart to new subband
594 +* Example output:
595 +
591 591  (% class="mark small" %)[3369]DRAGINO LWL01 Device
592 592  [3370]Frequency Band: US915 v1.5
593 593  [3373]OTAA
... ... @@ -612,11 +612,13 @@
612 612  [3382]freq mode intra
613 613  [3384]**scan chn mask 0x0001  ~-~-> reboot and works on Subband1 now**
614 614  
615 -* **Since firmware v1.6: **LWL02 works in chn mask 0x0000. where cover all subbands. so no need to use AT Commands to change subband and it can works for every subband
616 616  
621 +(% style="color:blue" %)**Since firmware v1.6: **(%%)LWL02 works in chn mask 0x0000. where cover all subbands. so no need to use AT Commands to change subband and it can works for every subband
617 617  
623 +
618 618  == 7.5 My sensor works for Helium AU915 before but not it doesn't work, Why? ==
619 619  
626 +
620 620  It is sub-band issue, See chapter 7.4.Helium Change the Subband for AU915 from subband2 to Subband1 which cause the sensor doesn't work.
621 621  
622 622  
... ... @@ -637,6 +637,8 @@
637 637  * (% style="color:red" %)**IN865**(%%):  frequency bands  IN865
638 638  * (% style="color:red" %)**CN779**(%%): frequency bands CN779
639 639  
647 +
648 +
640 640  = 9. Packing Info =
641 641  
642 642  
... ... @@ -656,7 +656,6 @@
656 656  Device Size: 69.2 x 29.2 x 14.8 mm
657 657  
658 658  
659 -
660 660  
661 661  )))
662 662  
... ... @@ -665,3 +665,7 @@
665 665  
666 666  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
667 667  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
676 +
677 +
678 +
679 +
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0