<
From version < 50.5 >
edited by Xiaoling
on 2022/08/19 09:11
To version < 50.2 >
edited by Xiaoling
on 2022/08/19 09:01
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -69,8 +69,6 @@
69 69  * Firmware upgradable via program port
70 70  
71 71  
72 -
73 -
74 74  == 1.3 Applications ==
75 75  
76 76  
... ... @@ -82,8 +82,6 @@
82 82  * Smart Factory
83 83  
84 84  
85 -
86 -
87 87  == 1.4 Dimension ==
88 88  
89 89  
... ... @@ -485,18 +485,13 @@
485 485  |(% style="width:184px" %)Send an uplink message|(% style="width:275px" %)(% style="color:green" %)**GREEN LED**(%%) blinks once
486 486  |(% style="width:184px" %)Got a downlink message|(% style="width:275px" %)(% style="color:blue" %)**BLUE LED**(%%) blinks once
487 487  
488 -
489 -
490 490  = 5. Battery & How to replace =
491 491  
492 -
493 493  == 5.1 Battery Type and replace ==
494 494  
495 -
496 496  (((
497 497  LDS02 is equipped with 2 x AAA LR03 batteries. If the batteries running low (shows 2.1v in the platform). User can buy generic AAA battery and replace it.
498 498  
499 -
500 500  (% style="color:red" %)**Note:**
501 501  
502 502  1. The LDS02 doesn't have any screw, use can use nail to open it by the middle.
... ... @@ -518,10 +518,8 @@
518 518  [[image:1654675278044-307.png]]
519 519  
520 520  
521 -
522 522  == 5.2 Power Consumption Analyze ==
523 523  
524 -
525 525  (((
526 526  Dragino battery powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimate battery life:
527 527  )))
... ... @@ -531,16 +531,12 @@
531 531  )))
532 532  
533 533  
534 -
535 535  = 6. Use AT Command =
536 536  
537 -
538 538  == 6.1 Access AT Command ==
539 539  
540 -
541 541  LDS02 supports AT Command set. User can use a USB to TTL adapter to configure LDS02 via use AT command, as below.
542 542  
543 -
544 544  [[image:image-20220609085453-1.png]]
545 545  
546 546  
... ... @@ -569,7 +569,7 @@
569 569  )))
570 570  
571 571  (((
572 -When entering the first command, the (% style="color:red" %)**RED LED**(%%) will on and user can now input AT Commands. After input all needed AT Commands, please input **AT+CLPM=1** to set the device to work in Low Power mode and (% style="color:red" %)**RED LED**(%%) will be off.
557 +When entering the first command, the (% style="color:red" %)**RED LED**(%%) will on and user can now input AT Commands. After input all needed AT Commands, please input AT+CLPM=1 to set the device to work in Low Power mode and (% style="color:red" %)**RED LED**(%%) will be off.
573 573  )))
574 574  
575 575  (((
... ... @@ -577,48 +577,39 @@
577 577  )))
578 578  
579 579  
580 -
581 581  = 7. FAQ =
582 582  
583 -
584 584  == 7.1 How to upgrade the image? ==
585 585  
586 -
587 587  User can upgrade the of LDS02 for bug fix, new features, or change working region. The upgrade instruction is here: [[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
588 588  
589 589  
590 -
591 591  == 7.2 How to change the LoRa Frequency Bands/Region? ==
592 592  
593 -
594 594  If user has for example US915 frequency and want to change it to AS923 frequency. User can follow the introduction for [[how to upgrade image>>||anchor="H7.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
595 595  
596 596  
597 -
598 598  == 7.3 Can I disable uplink for each event to save battery life? ==
599 599  
600 -
601 601  Yes, User can use below method to disable this:
602 602  
603 603  
604 -(% style="color:blue" %)**via AT Command**:
582 +(% style="color:#4f81bd" %)**via AT Command**:
605 605  
606 -(% style="color:red" %)**AT+DISALARM=1**(%%), End node will only send packet in TDC time.
584 +AT+DISALARM=1, End node will only send packet in TDC time.
607 607  
608 -(% style="color:red" %)**AT+DISALARM=0**(%%), End node will send packet in TDC time or status change for door sensor. 
586 +AT+DISALARM=0, End node will send packet in TDC time or status change for door sensor. 
609 609  
610 610  
611 -(% style="color:blue" %)**via LoRaWAN downlink Command**:
589 +(% style="color:#4f81bd" %)**via LoRaWAN downlink Command**:
612 612  
613 -(% style="color:red" %)**0xA701**(%%) : Equal to AT+DISALARM=1
591 +0xA701 : Equal to AT+DISALARM=1
614 614  
615 -(% style="color:red" %)**0xA700**(%%) : Equal to AT+DISALARM=0
593 +0xA700 : Equal to AT+DISALARM=0
616 616  
617 617  
618 -
619 619  = 8. Order Info =
620 620  
621 -
622 622  **Part Number: (% style="color:blue" %)LDS02-XXX(%%)**
623 623  
624 624  (% style="color:blue" %)**XXX:**
... ... @@ -633,13 +633,8 @@
633 633  * (% style="color:red" %)**IN865**(%%):  frequency bands  IN865
634 634  * (% style="color:red" %)**CN779**(%%): frequency bands CN779
635 635  
636 -
637 -
638 -
639 -
640 640  = 9. Packing Info =
641 641  
642 -
643 643  (((
644 644  **Package Includes**:
645 645  )))
... ... @@ -656,16 +656,12 @@
656 656  Device Size: 69.2 x 29.2 x 14.8 mm
657 657  
658 658  
659 -
660 660  
661 661  )))
662 662  
663 663  = 10. Support =
664 664  
665 -
666 666  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
667 667  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
668 668  
669 -
670 -
671 671  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0