22
23 = 1. Introduction =
24
25 == 1.1 ​What is LoRaWAN Soil pH Sensor ==
26
27 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
28
29 LSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:#4f81bd" %)pH (%%)**with high accuracy and stable value. The LSPH01 probe can be buried into soil for long time use.
30
31 The LoRa wireless technology used in LSPH01 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
32
33 LSPH01 is powered by (% style="color:#4f81bd" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
34
35 Each LSPH01 is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
36
37
38 [[image:1654580186518-415.png]]
39
40
41
42 == ​1.2 Features ==
43
44 * LoRaWAN 1.0.3 Class A
45 * Ultra-low power consumption
46 * Monitor soil pH with temperature compensation.
47 * Monitor soil temperature
48 * Monitor Battery Level
49 * Support pH calibration by end user
50 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
51 * AT Commands to change parameters
52 * Uplink on periodically
53 * Downlink to change configure
54 * IP66 Waterproof Enclosure
55 * IP68 rate for the Sensor Probe
56 * 8500mAh Battery for long term use
57
58 == 1.3 Probe Specification ==
59
60
61 (% style="color:#4f81bd" %)**Soil pH:**
62
63 * Range: 3 ~~ 10 pH
64 * Resolution: 0.01 pH
65 * Accuracy: ±2% under (0~~50 ℃, Accuracy will poor under 0 due to frozen)
66 * Temperature Compensation Range: 0 ~~ 50℃
67 * IP68 Protection
68 * Length: 3.5 meters
69
70 (% style="color:#4f81bd" %)**Soil Temperature:**
71
72 * Range -40℃~85℃
73 * Resolution: 0.1℃
74 * Accuracy: <±0.5℃(-10℃~40℃),<±0.8℃ (others)
75 * IP68 Protection
76 * Length: 3.5 meters
77
78 == 1.4 ​Applications ==
79
80 * Smart Agriculture
81
82 == 1.5 Pin mapping and power on ==
83
84 [[image:1654580482666-473.png]]
85
86
87
88 = 2. Configure LSPH01 to connect to LoRaWAN network =
89
90 == 2.1 How it works ==
91
92 (((
93 The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
94 )))
95
96 (((
97 In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.200BUseATCommand"]]to set the keys in the LSPH01.
98 )))
99
100
101 == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
102
103 (((
104 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
105 )))
106
107 (((
108
109 )))
110
111 (((
112 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
113 )))
114
115 (((
116 (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LSPH01.
117 )))
118
119 (((
120 Each LSPH01 is shipped with a sticker with the default device EUI as below:
121 )))
122
123
124 [[image:image-20220607135531-1.jpeg]]
125
126
127 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
128
129
130 **Register the device**
131
132 [[image:1654581442672-605.png]]
133
134
135
136 **Add APP EUI and DEV EUI**
137
138 [[image:1654581465717-368.png]]
139
140
141
142 **Add APP EUI in the application**
143
144 [[image:1654581493871-516.png]]
145
146
147
148 **Add APP KEY**
149
150 [[image:1654581517630-991.png]]
151
152
153 (% style="color:blue" %)**Step 2**(%%): Power on LSPH01
154
155
156 Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position).
157
158 [[image:image-20220607135918-2.png]]
159
160
161 (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
162
163 [[image:1654581590132-631.png]]
164
165
166
167 == 2.3 ​Uplink Payload ==
168
169 LSPH01 will uplink payload via LoRaWAN with below payload format: 
170
171 Uplink payload includes in total 11 bytes.
172
173 Normal uplink payload:
174
175 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
176 |(((
177 **Size**
178
179 **(bytes)**
180 )))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
181 |**Value**|[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(((
182 [[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
183
184 [[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
185 )))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
186 [[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
187 )))|Reserve|(((
188 [[Message Type>>||anchor="H2.3.6MessageType"]]
189 )))
190
191 [[image:1654581735133-458.png]]
192
193
194
195 === 2.3.1 Battery Info ===
196
197
198 Check the battery voltage for LSPH01.
199
200 Ex1: 0x0B45 = 2885mV
201
202 Ex2: 0x0B49 = 2889mV
203
204
205
206 === 2.3.2 DS18B20 Temperature sensor ===
207
208 This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
209
210
211 **Example**:
212
213 If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
214
215 If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
216
217
218
219 === 2.3.3 Soil pH ===
220
221 Range: 0 ~~ 14 pH
222
223 **Example:**
224
225 (% style="color:#037691" %)** 0x02B7(H) = 695(D) = 6.95pH**
226
227
228
229 === 2.3.4 Soil Temperature ===
230
231 Get Soil Temperature 
232
233
234 **Example**:
235
236 If payload is: **0105H**:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
237
238 If payload is: **FF3FH** :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
239
240
241
242 === 2.3.5 Interrupt Pin ===
243
244 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
245
246
247 **Example:**
248
249 0x00: Normal uplink packet.
250
251 0x01: Interrupt Uplink Packet.
252
253
254
255 === 2.3.6 Message Type ===
256
257 For a normal uplink payload, the message type is always 0x01.
258
259 Valid Message Type:
260
261
262 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
263 |**Message Type Code**|**Description**|**Payload**
264 |0x01|Normal Uplink|[[Normal Uplink Payload>>||anchor="H2.3Uplink Payload"]]
265 |0x02|Reply configures info|[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
266 |0x03|Reply Calibration Info|[[Calibration Payload>>||anchor="H2.7Calibration"]]
267
268 === 2.3.7 Decode payload in The Things Network ===
269
270 While using TTN network, you can add the payload format to decode the payload.
271
272
273 [[image:1654582541848-906.png]]
274
275 (((
276 The payload decoder function for TTN is here:
277 )))
278
279 (((
280 LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
281 )))
282
283
284
285 == 2.4 Uplink Interval ==
286
287 The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
288
289
290
291 == 2.5 ​Show Data in DataCake IoT Server ==
292
293 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
294
295
296 (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
297
298 (% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
299
300
301 [[image:1654583683416-869.png]]
302
303
304 [[image:1654583694084-878.png]]
305
306
307 (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
308
309 (% style="color:blue" %)**Step 4**(%%)**: Create LSPH01 product.**
310
311 [[image:1654583711590-413.png]]
312
313
314
315 [[image:1654583732798-193.png]]
316
317
318 [[image:1654583749683-259.png]]
319
320
321 (% style="color:blue" %)**Step 5**(%%)**: add payload decode**
322
323 Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
324
325
326 [[image:1654583770974-935.png]]
327
328 [[image:1654583781517-146.png]]
329
330
331 [[image:1654583791351-557.png]]
332
333
334 After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
335
336
337 [[image:1654583805491-713.png]]
338
339
340
341 == 2.6 Installation and Maintain ==
342
343 === 2.6.1 Before measurement ===
344
345 (((
346 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
347 )))
348
349
350
351 === 2.6.2 Measurement ===
352
353
354 (% style="color:#4f81bd" %)**Measurement the soil surface:**
355
356 [[image:1654584128046-287.png]]
357
358 Choose the proper measuring position. Split the surface soil according to the measured deep.
359
360 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things.
361
362 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting.
363
364 Put soil over the probe after insert. And start to measure.
365
366
367 (% style="color:#4f81bd" %)**Measurement inside soil:**
368
369 Dig a hole with diameter > 20CM.
370
371 Insert the probe inside, method like measure the surface.
372
373
374
375 === 2.6.3 Maintain Probe ===
376
377 1. (((
378 pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
379 )))
380 1. (((
381 After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
382 )))
383 1. (((
384 Probe reference electrode is also no strong, need to avoid strong force or hitting.
385 )))
386 1. (((
387 User should keep reference electrode wet while not use.
388 )))
389 1. (((
390 Avoid the probes to touch oily matter. Which will cause issue in accuracy.
391 )))
392 1. (((
393 The probe is IP68 can be put in water.
394
395
396
397 )))
398
399 == 2.7 Calibration ==
400
401 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
402
403 After stable, user can use below command to calibrate.
404
405 [[image:image-20220607144936-3.png]]
406
407
408 (% style="color:#037691" %)**Calibration Payload**
409
410 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
411 |(((
412 **Size**
413
414 **(bytes)**
415 )))|**1**|**1**|**1**|**7**|**1**
416 |**Value**|(((
417 PH4
418
419 Calibrate value
420 )))|PH6.86 Calibrate value|(((
421 PH9.18
422
423 Calibrate value
424 )))|Reserve|(((
425 [[Message Type>>||anchor="H2.3.6MessageType"]]
426
427 Always 0x03
428 )))
429
430
431 User can also send 0x14 downlink command to poll the current calibration payload.
432
433 [[image:image-20220607145603-4.png]]
434
435 * Reply to the confirmation package: 14 01
436 * Reply to non-confirmed packet: 14 00
437
438
439 == 2.8 Frequency Plans ==
440
441 (((
442 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
443 )))
444
445
446 === 2.8.1 EU863-870 (EU868) ===
447
448 (% style="color:blue" %)**Uplink:**
449
450 868.1 - SF7BW125 to SF12BW125
451
452 868.3 - SF7BW125 to SF12BW125 and SF7BW250
453
454 868.5 - SF7BW125 to SF12BW125
455
456 867.1 - SF7BW125 to SF12BW125
457
458 867.3 - SF7BW125 to SF12BW125
459
460 867.5 - SF7BW125 to SF12BW125
461
462 867.7 - SF7BW125 to SF12BW125
463
464 867.9 - SF7BW125 to SF12BW125
465
466 868.8 - FSK
467
468
469 (% style="color:blue" %)**Downlink:**
470
471 Uplink channels 1-9 (RX1)
472
473 869.525 - SF9BW125 (RX2 downlink only)
474
475
476
477 === 2.8.2 US902-928(US915) ===
478
479 (((
480 Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
481 )))
482
483 (((
484 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
485 )))
486
487 (((
488 After Join success, the end node will switch to the correct sub band by:
489 )))
490
491 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
492 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
493
494
495 === 2.8.3 CN470-510 (CN470) ===
496
497 Used in China, Default use CHE=1
498
499 (% style="color:blue" %)**Uplink:**
500
501 486.3 - SF7BW125 to SF12BW125
502
503 486.5 - SF7BW125 to SF12BW125
504
505 486.7 - SF7BW125 to SF12BW125
506
507 486.9 - SF7BW125 to SF12BW125
508
509 487.1 - SF7BW125 to SF12BW125
510
511 487.3 - SF7BW125 to SF12BW125
512
513 487.5 - SF7BW125 to SF12BW125
514
515 487.7 - SF7BW125 to SF12BW125
516
517
518 (% style="color:blue" %)**Downlink:**
519
520 506.7 - SF7BW125 to SF12BW125
521
522 506.9 - SF7BW125 to SF12BW125
523
524 507.1 - SF7BW125 to SF12BW125
525
526 507.3 - SF7BW125 to SF12BW125
527
528 507.5 - SF7BW125 to SF12BW125
529
530 507.7 - SF7BW125 to SF12BW125
531
532 507.9 - SF7BW125 to SF12BW125
533
534 508.1 - SF7BW125 to SF12BW125
535
536 505.3 - SF12BW125 (RX2 downlink only)
537
538
539
540 === 2.8.4 AU915-928(AU915) ===
541
542 (((
543 Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
544 )))
545
546 (((
547 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
548 )))
549
550 (((
551
552 )))
553
554 (((
555 After Join success, the end node will switch to the correct sub band by:
556 )))
557
558 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
559 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
560
561
562 === 2.8.5 AS920-923 & AS923-925 (AS923) ===
563
564 (% style="color:blue" %)**Default Uplink channel:**
565
566 923.2 - SF7BW125 to SF10BW125
567
568 923.4 - SF7BW125 to SF10BW125
569
570
571 (% style="color:blue" %)**Additional Uplink Channel**:
572
573 (OTAA mode, channel added by JoinAccept message)
574
575
576 (% style="color:blue" %)**AS920~~AS923 for Japan, Malaysia, Singapore**:
577
578 922.2 - SF7BW125 to SF10BW125
579
580 922.4 - SF7BW125 to SF10BW125
581
582 922.6 - SF7BW125 to SF10BW125
583
584 922.8 - SF7BW125 to SF10BW125
585
586 923.0 - SF7BW125 to SF10BW125
587
588 922.0 - SF7BW125 to SF10BW125
589
590
591 (% style="color:blue" %)**AS923 ~~ AS925 for Brunei, Cambodia, Hong Kong, Indonesia, Laos, Taiwan, Thailand, Vietnam**:
592
593 923.6 - SF7BW125 to SF10BW125
594
595 923.8 - SF7BW125 to SF10BW125
596
597 924.0 - SF7BW125 to SF10BW125
598
599 924.2 - SF7BW125 to SF10BW125
600
601 924.4 - SF7BW125 to SF10BW125
602
603 924.6 - SF7BW125 to SF10BW125
604
605
606 (% style="color:blue" %)**Downlink:**
607
608 Uplink channels 1-8 (RX1)
609
610 923.2 - SF10BW125 (RX2)
611
612
613
614 === 2.8.6 KR920-923 (KR920) ===
615
616 (% style="color:blue" %)**Default channel:**
617
618 922.1 - SF7BW125 to SF12BW125
619
620 922.3 - SF7BW125 to SF12BW125
621
622 922.5 - SF7BW125 to SF12BW125
623
624
625 (% style="color:blue" %)**Uplink: (OTAA mode, channel added by JoinAccept message)**
626
627 922.1 - SF7BW125 to SF12BW125
628
629 922.3 - SF7BW125 to SF12BW125
630
631 922.5 - SF7BW125 to SF12BW125
632
633 922.7 - SF7BW125 to SF12BW125
634
635 922.9 - SF7BW125 to SF12BW125
636
637 923.1 - SF7BW125 to SF12BW125
638
639 923.3 - SF7BW125 to SF12BW125
640
641
642 (% style="color:blue" %)**Downlink:**
643
644 Uplink channels 1-7(RX1)
645
646 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
647
648
649 === 2.8.7 IN865-867 (IN865) ===
650
651 (% style="color:blue" %)**Uplink:**
652
653 865.0625 - SF7BW125 to SF12BW125
654
655 865.4025 - SF7BW125 to SF12BW125
656
657 865.9850 - SF7BW125 to SF12BW125
658
659
660 (% style="color:blue" %)**Downlink:**
661
662 Uplink channels 1-3 (RX1)
663
664 866.550 - SF10BW125 (RX2)
665
666
667
668 == 2.9 LED Indicator ==
669
670 The LSPH01 has an internal LED which is to show the status of different state.
671
672 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
673 * Blink once when device transmit a packet.
674
675
676 == 2.10 ​Firmware Change Log ==
677
678
679 **Firmware download link:**
680
681 [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
682
683
684 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
685
686
687
688 = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
689
690 Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
691
692 * AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
693 * LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
694
695
696 There are two kinds of commands to configure LSPH01, they are:
697
698 * **(% style="color:#4F81BD" %) General Commands**.
699
700 These commands are to configure:
701
702 * General system settings like: uplink interval.
703 * LoRaWAN protocol & radio related command.
704
705 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
706
707
708 * **(% style="color:#4F81BD" %) Commands special design for LSPH01**
709
710 These commands only valid for LSPH01, as below:
711
712
713 1.
714 11. Set Transmit Interval Time
715
716 Feature: Change LoRaWAN End Node Transmit Interval.
717
718 **AT Command: AT+TDC**
719
720 |**Command Example**|**Function**|**Response**
721 |AT+TDC=?|Show current transmit Interval|(((
722 30000
723
724 OK
725
726 the interval is 30000ms = 30s
727 )))
728 |AT+TDC=60000|Set Transmit Interval|(((
729 OK
730
731 Set transmit interval to 60000ms = 60 seconds
732 )))
733
734 **Downlink Command: 0x01**
735
736 Format: Command Code (0x01) followed by 3 bytes time value.
737
738 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
739
740 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
741 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
742
743 1.
744 11. Set Interrupt Mode
745
746 Feature, Set Interrupt mode for GPIO_EXIT.
747
748 **AT Command: AT+INTMOD**
749
750 |**Command Example**|**Function**|**Response**
751 |AT+INTMOD=?|Show current interrupt mode|(((
752 0
753
754 OK
755
756 the mode is 0 = No interruption
757 )))
758 |AT+INTMOD=2|(((
759 Set Transmit Interval
760
761 1. (Disable Interrupt),
762 1. (Trigger by rising and falling edge),
763 1. (Trigger by falling edge)
764 1. (Trigger by rising edge)
765 )))|OK
766
767 **Downlink Command: 0x06**
768
769 Format: Command Code (0x06) followed by 3 bytes.
770
771 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
772
773 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
774 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
775
776 1.
777 11. Calibrate Sensor
778
779 Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
780
781
782
783 1.
784 11. Get Firmware Version Info
785
786 Feature: use downlink to get firmware version.
787
788
789 **Downlink Command: 0x26**
790
791
792 |**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)**
793 |Get Firmware Version Info|Any|26|2
794
795 * Reply to the confirmation package: 26 01
796 * Reply to non-confirmed packet: 26 00
797
798 Device will send an uplink after got this downlink command. With below payload:
799
800 Configures info payload:
801
802 |(((
803 **Size**
804
805 **(bytes)**
806 )))|**1**|**1**|**1**|**1**|**1**|**5**|**1**
807 |**Value**|Software Type|(((
808 Frequency
809
810 Band
811 )))|Sub-band|(((
812 Firmware
813
814 Version
815 )))|Sensor Type|Reserve|(((
816 [[Message>>path:#Message_Type]]
817
818 [[Type>>path:#Message_Type]]
819
820 Always 0x02
821 )))
822
823 **Software Type**: Always 0x03 for LSPH01
824
825
826 **Frequency Band**:
827
828 *0x01: EU868
829
830 *0x02: US915
831
832 *0x03: IN865
833
834 *0x04: AU915
835
836 *0x05: KZ865
837
838 *0x06: RU864
839
840 *0x07: AS923
841
842 *0x08: AS923-1
843
844 *0x09: AS923-2
845
846 *0xa0: AS923-3
847
848
849 **Sub-Band**: value 0x00 ~~ 0x08
850
851
852 **Firmware Version**: 0x0100, Means: v1.0.0 version
853
854
855 **Sensor Type**:
856
857 0x01: LSE01
858
859 0x02: LDDS75
860
861 0x03: LDDS20
862
863 0x04: LLMS01
864
865 0x05: LSPH01
866
867 0x06: LSNPK01
868
869 0x07: LDDS12
870
871
872
873
874
875
876 1. Battery & How to replace
877 11. Battery Type
878
879 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
880
881
882 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
883
884 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
885
886
887 Minimum Working Voltage for the LSPH01:
888
889 LSPH01:  2.45v ~~ 3.6v
890
891
892 1.
893 11. Replace Battery
894
895 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
896
897 And make sure the positive and negative pins match.
898
899
900
901 1.
902 11. Power Consumption Analyze
903
904 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
905
906
907 Instruction to use as below:
908
909
910 Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
911
912 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
913
914
915 Step 2: Open it and choose
916
917 * Product Model
918 * Uplink Interval
919 * Working Mode
920
921 And the Life expectation in difference case will be shown on the right.
922
923 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
924
925
926 The battery related documents as below:
927
928 * [[Battery Dimension>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]],
929 * [[Lithium-Thionyl Chloride Battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] datasheet
930 * [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
931
932 |(((
933 JST-XH-2P connector
934 )))
935
936 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
937
938
939
940 1.
941 11.
942 111. ​Battery Note
943
944 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
945
946
947 1.
948 11.
949 111. ​Replace the battery
950
951 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
952
953
954 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
955
956
957
958
959
960
961 1. Use AT Command
962 11. Access AT Commands
963
964 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
965
966 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
967
968 Connection:
969
970 USB TTL GND <~-~-~-~-> GND
971
972 USB TTL TXD <~-~-~-~-> UART_RXD
973
974 USB TTL RXD <~-~-~-~-> UART_TXD
975
976
977 In the PC, you need to set the serial baud rate to **9600** to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
978
979
980 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
981
982 Valid AT Command please check [[Configure Device>>path:#Configure_Device]].
983
984
985
986
987 1. FAQ
988 11. How to change the LoRa Frequency Bands/Region
989
990 You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]].
991 When downloading the images, choose the required image file for download. ​
992
993
994
995 1. Trouble Shooting
996 11. AT Commands input doesn’t work
997
998 In the case if user can see the console output but can’t type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn’t send **ENTER** while press the send key, user need to add ENTER in their string.
999
1000
1001 1. Order Info
1002
1003 Part Number: **LSPH01-XX**
1004
1005
1006 **XX**: The default frequency band
1007
1008 * **AS923**: LoRaWAN AS923 band
1009 * **AU915**: LoRaWAN AU915 band
1010 * **EU433**: LoRaWAN EU433 band
1011 * **EU868**: LoRaWAN EU868 band
1012 * **KR920**: LoRaWAN KR920 band
1013 * **US915**: LoRaWAN US915 band
1014 * **IN865**: LoRaWAN IN865 band
1015 * **CN470**: LoRaWAN CN470 band
1016
1017 1. ​Packing Info
1018
1019 **Package Includes**:
1020
1021 * LSPH01 LoRaWAN Soil Ph Sensor x 1
1022
1023 **Dimension and weight**:
1024
1025 * Device Size: cm
1026 * Device Weight: g
1027 * Package Size / pcs : cm
1028 * Weight / pcs : g
1029
1030 = 10. ​Support =
1031
1032 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1033 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to
1034
1035 [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
1036
1037
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0