Changes for page CPN01- NB-IoT Outdoor Open/Close Dry Contact Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -59,6 +59,7 @@ 59 59 * 8500mAh Battery for long-term use 60 60 61 61 62 + 62 62 == 1.3 Specification == 63 63 64 64 ... ... @@ -77,6 +77,7 @@ 77 77 * B28 @H-FDD: 700MHz 78 78 79 79 81 + 80 80 == 1.4 Installation == 81 81 82 82 ... ... @@ -88,7 +88,6 @@ 88 88 [[image:image-20221117175717-1.png||height="323" width="861"]] 89 89 90 90 91 - 92 92 == 1.5 Applications == 93 93 94 94 ... ... @@ -97,6 +97,7 @@ 97 97 * Dry Contact Detection 98 98 99 99 101 + 100 100 == 1.6 Mechanical == 101 101 102 102 ... ... @@ -371,6 +371,7 @@ 371 371 * (% style="color:#037691" %)**8 sets of recorded data: Contact Status, Total pulse, The last open duration ,Time stamp :**(%%) 0100000e00002663510f39,....... 372 372 373 373 376 + 374 374 == 2.4 Payload Explanation and Sensor Interface == 375 375 376 376 === 2.4.1 Device ID === ... ... @@ -481,11 +481,11 @@ 481 481 482 482 By default, CPN01 prints the downlink payload to console port. 483 483 484 -(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:5 20px" %)485 -|(% style="width:2 26px" %)**Downlink Control Type**|(% style="width:25px" %)**FPort**|(% style="width:98px" %)**Type Code**|(% style="width:147px" %)**Downlink payload size(bytes)**486 -|(% style="width:2 26px" %)TDC(Transmit Time Interval)|(% style="width:25px" %)Any|(% style="width:98px" %)01|(% style="width:147px" %)4487 -|(% style="width:2 26px" %)RESET|(% style="width:25px" %)Any|(% style="width:98px" %)04|(% style="width:147px" %)2488 -|(% style="width:2 26px" %)INTMOD|(% style="width:25px" %)Any|(% style="width:98px" %)06|(% style="width:147px" %)4487 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:505px" %) 488 +|(% style="width:207px" %)**Downlink Control Type**|(% style="width:56px" %)**FPort**|(% style="width:93px" %)**Type Code**|(% style="width:144px" %)**Downlink payload size(bytes)** 489 +|(% style="width:207px" %)TDC(Transmit Time Interval)|(% style="width:56px" %)Any|(% style="width:93px" %)01|(% style="width:144px" %)4 490 +|(% style="width:207px" %)RESET|(% style="width:56px" %)Any|(% style="width:93px" %)04|(% style="width:144px" %)2 491 +|(% style="width:207px" %)INTMOD|(% style="width:56px" %)Any|(% style="width:93px" %)06|(% style="width:144px" %)4 489 489 490 490 491 491 **Examples:** ... ... @@ -517,6 +517,7 @@ 517 517 * For each uplink probe, LED will be on for 500ms. 518 518 519 519 523 + 520 520 == 2.7 Alarm Base on Timeout == 521 521 522 522 ... ... @@ -569,9 +569,9 @@ 569 569 (% style="color:blue" %)**AT Command: AT+CLRDTA** 570 570 571 571 572 -(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width: 527px" %)573 -|(% style="width:158px" %)**Command Example**|(% style="width:1 85px" %)**Function**|(% style="width:173px" %)**Response**574 -|(% style="width:158px" %)AT+CLRDTA|(% style="width:1 85px" %)Clear flash storage for data log feature.|(% style="width:173px" %)(((576 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:498px" %) 577 +|(% style="width:158px" %)**Command Example**|(% style="width:169px" %)**Function**|(% style="width:167px" %)**Response** 578 +|(% style="width:158px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|(% style="width:167px" %)((( 575 575 Clear all stored sensor data…OK 576 576 ))) 577 577 ... ... @@ -590,7 +590,6 @@ 590 590 |(% style="width:158px" %)AT+TTRMOD=0|(% style="width:225px" %)Count and trigger from close to open (falling edge)|(% style="width:88px" %)OK 591 591 592 592 593 - 594 594 == 2.11 Set the calculate flag == 595 595 596 596 ... ... @@ -848,6 +848,7 @@ 848 848 * Weight: 420g 849 849 850 850 854 + 851 851 = 9. Support = 852 852 853 853