Changes for page CPN01- NB-IoT Outdoor Open/Close Dry Contact Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -58,7 +58,6 @@ 58 58 * Micro SIM card slot for NB-IoT SIM 59 59 * 8500mAh Battery for long-term use 60 60 61 - 62 62 == 1.3 Specification == 63 63 64 64 ... ... @@ -76,7 +76,6 @@ 76 76 * B20 @H-FDD: 800MHz 77 77 * B28 @H-FDD: 700MHz 78 78 79 - 80 80 == 1.4 Installation == 81 81 82 82 ... ... @@ -88,7 +88,6 @@ 88 88 [[image:image-20221117175717-1.png||height="323" width="861"]] 89 89 90 90 91 - 92 92 == 1.5 Applications == 93 93 94 94 ... ... @@ -96,7 +96,6 @@ 96 96 * Pulse meter application 97 97 * Dry Contact Detection 98 98 99 - 100 100 == 1.6 Mechanical == 101 101 102 102 ... ... @@ -370,7 +370,6 @@ 370 370 371 371 * (% style="color:#037691" %)**8 sets of recorded data: Contact Status, Total pulse, The last open duration ,Time stamp :**(%%) 0100000e00002663510f39,....... 372 372 373 - 374 374 == 2.4 Payload Explanation and Sensor Interface == 375 375 376 376 === 2.4.1 Device ID === ... ... @@ -481,13 +481,12 @@ 481 481 482 482 By default, CPN01 prints the downlink payload to console port. 483 483 484 -(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:5 20px" %)485 -|(% style="width:2 26px" %)**Downlink Control Type**|(% style="width:25px" %)**FPort**|(% style="width:98px" %)**Type Code**|(% style="width:147px" %)**Downlink payload size(bytes)**486 -|(% style="width:2 26px" %)TDC(Transmit Time Interval)|(% style="width:25px" %)Any|(% style="width:98px" %)01|(% style="width:147px" %)4487 -|(% style="width:2 26px" %)RESET|(% style="width:25px" %)Any|(% style="width:98px" %)04|(% style="width:147px" %)2488 -|(% style="width:2 26px" %)INTMOD|(% style="width:25px" %)Any|(% style="width:98px" %)06|(% style="width:147px" %)4479 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:505px" %) 480 +|(% style="width:207px" %)**Downlink Control Type**|(% style="width:56px" %)**FPort**|(% style="width:93px" %)**Type Code**|(% style="width:144px" %)**Downlink payload size(bytes)** 481 +|(% style="width:207px" %)TDC(Transmit Time Interval)|(% style="width:56px" %)Any|(% style="width:93px" %)01|(% style="width:144px" %)4 482 +|(% style="width:207px" %)RESET|(% style="width:56px" %)Any|(% style="width:93px" %)04|(% style="width:144px" %)2 483 +|(% style="width:207px" %)INTMOD|(% style="width:56px" %)Any|(% style="width:93px" %)06|(% style="width:144px" %)4 489 489 490 - 491 491 **Examples:** 492 492 493 493 * (% style="color:#037691" %)**Set TDC** ... ... @@ -516,7 +516,6 @@ 516 516 * After CPN01 join NB-IoT network. The LED will be ON for 3 seconds. 517 517 * For each uplink probe, LED will be on for 500ms. 518 518 519 - 520 520 == 2.7 Alarm Base on Timeout == 521 521 522 522 ... ... @@ -559,8 +559,6 @@ 559 559 |(% style="width:158px" %)AT+DEBUG=0|(% style="width:196px" %)Disable debug mode to 0|(% style="width:74px" %)OK 560 560 |(% style="width:158px" %)AT+DEBUG=1|(% style="width:196px" %)Enable debug mode to 1|(% style="width:74px" %)OK 561 561 562 - 563 - 564 564 == 2.9 Clear Flash Record == 565 565 566 566 ... ... @@ -568,8 +568,12 @@ 568 568 569 569 (% style="color:blue" %)**AT Command: AT+CLRDTA** 570 570 571 -[[image:image-20221021111527-19.png]] 572 572 563 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:498px" %) 564 +|(% style="width:158px" %)**Command Example**|(% style="width:169px" %)**Function**|(% style="width:167px" %)**Response** 565 +|(% style="width:158px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|(% style="width:167px" %)((( 566 +Clear all stored sensor data…OK 567 +))) 573 573 574 574 == 2.10 Set trigger mode == 575 575 ... ... @@ -578,9 +578,11 @@ 578 578 579 579 Feature: Set the trigger interrupt mode. 580 580 581 -[[image:image-20221021111552-20.png]] 576 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:472px" %) 577 +|(% style="width:158px" %)**Command Example**|(% style="width:225px" %)**Function**|(% style="width:88px" %)**Response** 578 +|(% style="width:158px" %)AT+TTRMOD=1|(% style="width:225px" %)Count and trigger from open to close (rising edge)|(% style="width:88px" %)OK 579 +|(% style="width:158px" %)AT+TTRMOD=0|(% style="width:225px" %)Count and trigger from close to open (falling edge)|(% style="width:88px" %)OK 582 582 583 - 584 584 == 2.11 Set the calculate flag == 585 585 586 586 ... ... @@ -588,8 +588,11 @@ 588 588 589 589 (% style="color:blue" %)**AT Command: AT+CALCFLAG** 590 590 591 -[[image:image-20221021111711-22.png]] 592 592 589 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:430px" %) 590 +|(% style="width:158px" %)**Command Example**|(% style="width:196px" %)**Function**|(% style="width:74px" %)**Response** 591 +|(% style="width:158px" %)AT+CALCFLAG=1|(% style="width:196px" %)Set the calculate flag to 1|(% style="width:74px" %)OK 592 +|(% style="width:158px" %)AT+CALCFLAG=2|(% style="width:196px" %)Set the calculate flag to 2|(% style="width:74px" %)OK 593 593 594 594 == 2.12 Set count number == 595 595 ... ... @@ -598,8 +598,11 @@ 598 598 599 599 (% style="color:blue" %)**AT Command: AT+SETCNT** 600 600 601 -[[image:image-20221021111748-24.png]] 602 602 602 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:459px" %) 603 +|(% style="width:158px" %)**Command Example**|(% style="width:239px" %)**Function**|(% style="width:85px" %)**Response** 604 +|(% style="width:158px" %)AT+SETCNT=0|(% style="width:239px" %)Set the count number to 0|(% style="width:85px" %)OK 605 +|(% style="width:158px" %)AT+SETCNT=100|(% style="width:239px" %)Set the count number to 100|(% style="width:85px" %)OK 603 603 604 604 == 2.13 Set the number of data to be uploaded and the recording time == 605 605 ... ... @@ -631,60 +631,14 @@ 631 631 Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]] 632 632 633 633 634 -== 2.16 BatteryAnalysis==637 +== 2.16 Battery & Power Consumption == 635 635 636 -=== 2.16.1 Battery Type === 637 637 640 +CPN01 uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 638 638 639 - The CPN01 batteryisacombinationof an 8500mAh Li/SOCI2 Battery andaSuperCapacitor. The batteryisnon-rechargeablebattery typewithaow discharge rate(<2%per year). Thistypeofbatterys commonly used inIoT devicessuch as water meter.642 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 640 640 641 -The battery is designed to last for several years depends on the actual use environment and update interval. 642 642 643 -The battery-related documents as below: 644 - 645 -* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 646 - 647 -* [[Lithium-Thionyl Chloride Battery datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 648 - 649 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 650 - 651 -[[image:image-20221021111911-26.png]] 652 - 653 - 654 -=== 2.16.2 Power consumption Analyze === 655 - 656 - 657 -Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 658 - 659 -Instruction to use as below: 660 - 661 -(% style="color:blue" %)**Step 1: **(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 662 - 663 -(% style="color:blue" %)**Step 2: **(%%) Open it and choose 664 - 665 -* Product Model 666 - 667 -* Uplink Interval 668 - 669 -* Working Mode 670 - 671 -And the Life expectation in difference case will be shown on the right. 672 - 673 -[[image:1666596205057-567.png]] 674 - 675 - 676 -=== 2.16.3 Battery Note === 677 - 678 - 679 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 680 - 681 - 682 -=== 2.16.4 Replace the battery === 683 - 684 - 685 -The default battery pack of CPN01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). 686 - 687 - 688 688 = 3. Access NB-IoT Module = 689 689 690 690 ... ... @@ -828,6 +828,7 @@ 828 828 * Weight: 420g 829 829 830 830 788 + 831 831 = 9. Support = 832 832 833 833